A Randomized Comparison Simulating Face to Face Endotracheal Intubation of Pentax Airway Scope, C-MAC Video Laryngoscope, Glidescope Video Laryngoscope, and Macintosh Laryngoscope

被引:6
|
作者
Choi, Hyun Young [1 ]
Oh, Young Min [2 ]
Kang, Gu Hyun [1 ]
Kang, Hyunggoo [3 ]
Jang, Yong Soo [1 ]
Kim, Wonhee [1 ]
Kim, Euichung [4 ]
Cho, Young Soon [5 ]
Choi, Hyukjoong [3 ]
Kim, Hyunjong [6 ]
Kim, Gyoung Yong [7 ]
机构
[1] Hallym Univ, Kangnam Sacred Heart Hosp, Coll Med, Dept Emergency Med, Seoul 150950, South Korea
[2] Catholic Univ Korea, Uijeongbu St Marys Hosp, Coll Med, Dept Emergency Med, Uijongbu 480717, South Korea
[3] Hanyang Univ, Coll Med, Dept Emergency Med, Seoul 133791, South Korea
[4] CHA Univ, Sch Med, Dept Emergency Med, Songnam 463712, Gyeonggi Do, South Korea
[5] Soonchunhyang Univ, Bucheon Hosp, Dept Emergency Med, Bucheon 420767, South Korea
[6] Inje Univ, Ilsan Paik Hosp, Dept Emergency Med, Ilsan 411706, South Korea
[7] Gyeonggi Fire Serv Acad, Yongin 449882, South Korea
关键词
TRACHEAL INTUBATION; MANAGEMENT;
D O I
10.1155/2015/961782
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Objectives. Early airway management is very important for severely ill patients. This study aimed to investigate the efficacy of face to face intubation in four different types of laryngoscopes (Macintosh laryngoscope, Pentax airway scope (AWS), Glidescope video laryngoscope (GVL), and C-MAC video laryngoscope (C-MAC)). Method. Ninety-five nurses and emergency medical technicians were trained to use the AWS, C-MAC, GVL and Macintosh laryngoscope with standard airway trainer manikin and face to face intubation. We compared VCET (vocal cord exposure time), tube pass time, 1st ventilation time, VCET to tube pass time, tube pass time to 1st ventilation time, and POGO (percentage of glottis opening) score. In addition, we compared success rate according to the number of attempts and complications. Result. VCET was similar among all laryngoscopes and POGO score was higher in AWS. AWS and Macintosh blade were faster than GVL and C-MAC in total intubation time. Face to face intubation success rate was lower in GVL than other laryngoscopes. Conclusion. AWS and Macintosh were favorable laryngoscopes in face to face intubation. GVL had disadvantage performing face to face intubation.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A Comparison of the GlideScope Video Laryngoscope to the C-MAC Video Laryngoscope for Intubation in the Emergency Department
    Mosier, Jarrod
    Chiu, Stephen
    Patanwala, Asad E.
    Sakles, John C.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2013, 61 (04) : 414 - 420
  • [2] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Ji Young Yoo
    Yun Jeong Chae
    Young Bok Lee
    Sujin Kim
    Jaemoon Lee
    Dae Hee Kim
    [J]. Scientific Reports, 8
  • [3] A Comparison of the GlideScope® Video Laryngoscope to the C-MAC® Video Laryngoscope for Tracheal Intubation in the Emergency Department
    Sakles, J. C.
    Mosier, J.
    Chiu, S.
    Patanwala, A.
    [J]. ANNALS OF EMERGENCY MEDICINE, 2012, 60 (04) : S63 - S63
  • [4] A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation
    Yoo, Ji Young
    Chae, Yun Jeong
    Lee, Young Bok
    Kim, Sujin
    Lee, Jaemoon
    Kim, Dae Hee
    [J]. SCIENTIFIC REPORTS, 2018, 8
  • [5] Comparison of three videolaryngoscopes: Pentax Airway Scope, C-MAC™, Glidescope® vs the Macintosh laryngoscope for tracheal intubation
    Teoh, W. H. L.
    Saxena, S.
    Shah, M. K.
    Sia, A. T. H.
    [J]. ANAESTHESIA, 2010, 65 (11) : 1126 - 1132
  • [6] A Comparison of the C-MAC Video Laryngoscope to the Macintosh Direct Laryngoscope for Intubation in the Emergency Department
    Sakles, John C.
    Mosier, Jarrod
    Chiu, Stephen
    Cosentino, Mari
    Kalin, Leah
    [J]. ANNALS OF EMERGENCY MEDICINE, 2012, 60 (06) : 739 - 748
  • [7] Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU
    Ruediger R Noppens
    Stephanie Geimer
    Nicole Eisel
    Matthias David
    Tim Piepho
    [J]. Critical Care, 16
  • [8] Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU
    Noppens, Ruediger R.
    Geimer, Stephanie
    Eisel, Nicole
    David, Matthias
    Piepho, Tim
    [J]. CRITICAL CARE, 2012, 16 (03):
  • [9] Comparison of the C-MAC video laryngoscope to the Macintosh laryngoscope for intubation of blunt trauma patients in the ED
    Goksu, Erkan
    Kilic, Taylan
    Yildiz, Gunay
    Unal, Aslihan
    Kartal, Mutlu
    [J]. TURKISH JOURNAL OF EMERGENCY MEDICINE, 2016, 16 (02) : 53 - 56
  • [10] Comparative Performance of C-MAC Video Laryngoscope and Macintosh Direct Laryngoscope for Emergency Intubation
    Xue, Fu S.
    Liao, Xu
    Cheng, Yi
    [J]. ANNALS OF EMERGENCY MEDICINE, 2012, 60 (06) : 817 - 818