Towards an Integrated System as Point-of-Care Device for the Optical Detection of Sepsis Biomarkers

被引:9
|
作者
Giannetti, Ambra [1 ]
Trono, Cosimo [1 ]
Porro, Giampiero [2 ]
Domenici, Claudio [3 ]
Puntoni, Mariarita [3 ]
Baldini, Francesco [1 ]
机构
[1] CNR, IFAC, Ist Fis Applicata Nello Carrara, Sesto Fiorentino 50019, FI, Italy
[2] DataMED Srl, Peschiera Garda 20068, MI, Italy
[3] CNR, IFC, Ist Fisiol Clin, Pisa 56124, Italy
基金
欧盟地平线“2020”;
关键词
C-reactive protein; neopterin; POCT; sepsis; immunoassay; biochip; fluorescence; C-REACTIVE PROTEIN; SERUM NEOPTERIN; PROCALCITONIN; BACTERIAL; LEVEL; SHOCK; RISK; UNIT;
D O I
10.3390/chemosensors8010012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Severe infection and sepsis are a common, expensive, and frequently fatal conditions in critically ill patients. The sepsis diagnosis is not trivial, since it is an extremely complex chain of events involving inflammatory and anti-inflammatory processes, cellular reactions, and circulatory disorders. For these reasons, delay in diagnosis and initiation of drug treatments have shown to be crucial for this pathology. Moreover, a multitude of biomarkers has been proposed, many more than for other pathologies. In order to select optimal treatments for the highly heterogeneous group of sepsis patients and to reduce costs, novel multiplexed tools that better characterize the patient and his or her specific immune response are highly desired. In order to achieve the fundament of drastically improved multi-analyte detection and to attain low limits of detection in diagnostics, the area of point-of-care testing (POCT) technology is developing quickly, leading to the production of instruments, the reliability of which is continuously increasing. For this purpose, a selection of two biomarkers-C-reactive protein (CRP) and neopterin (NP)-was studied in this paper and a fluorescence-based integrated optical system, suitable for future POCT applications, was implemented that is capable of performing the simultaneous measurement of the two different biomarkers in replicate. A limit of detection of 10 and 2.1 mu g L-1 was achieved for CRP and NP spiked in commercially available human serum, respectively. Moreover, measurements on both biomarkers were also performed on serum samples collected from septic patients.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Dual-Enhanced Plasmonic Biosensing for Point-of-Care Sepsis Detection
    Chin, Lip Ket
    Yang, Jun-Yeong
    Chousterman, Benjamin
    Jung, Sunghoon
    Kim, Do-Geun
    Kim, Dong-Ho
    Lee, Seunghun
    Castro, Cesar M.
    Weissleder, Ralph
    Park, Sung-Gyu
    Im, Hyungsoon
    ACS NANO, 2023, 17 (04) : 3610 - 3619
  • [32] Integrated fluorescence correlation spectroscopy device for point-of-care clinical applications
    Olson, Eben
    Torres, Richard
    Levene, Michael J.
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (07): : 1074 - 1082
  • [33] Integrated optical microfluidic biosensor using a polycarbazole photodetector for point-of-care detection of hormonal compounds
    Pires, Nuno Miguel Matos
    Dong, Tao
    Hanke, Ulrik
    Hoivik, Nils
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (09)
  • [34] Towards detection and diagnosis of Ebola virus disease at point-of-care
    Kaushik, Ajeet
    Tiwari, Sneham
    Jayant, Rahul Dev
    Marty, Aileen
    Nair, Madhavan
    BIOSENSORS & BIOELECTRONICS, 2016, 75 : 254 - 272
  • [35] Ammonia detection: A pathway towards potential point-of-care diagnostics
    Rath, Ronil J.
    Herrington, Jack O.
    Adeel, Muhammad
    Guder, Firat
    Dehghani, Fariba
    Farajikhah, Syamak
    BIOSENSORS & BIOELECTRONICS, 2024, 251
  • [36] Point-of-care data management in an integrated delivery health care system
    Jones, JB
    CLINICAL CHEMISTRY, 1999, 45 (06) : S37 - S37
  • [37] Engineering a Point-of-Care Paper-Microfluidic Electrochemical Device Applied to the Multiplexed Quantitative Detection of Biomarkers in Sputum
    Gutierrez-Capitan, Manuel
    Sanchis, Ana
    Carvalho, Estela O.
    Baldi, Antonio
    Vilaplana, Lluisa
    Cardoso, Vanessa F.
    Calleja, Alvaro
    Wei, Mingxing
    de la Rica, Roberto
    Hoyo, Javier
    Bassegoda, Arnau
    Tzanov, Tzanko
    Marco, Maria-Pilar
    Lanceros-Mendez, Senentxu
    Fernandez-Sanchez, Cesar
    ACS SENSORS, 2023, 8 (08) : 3032 - 3042
  • [38] Development of Hand-Held Point-of-Care Diagnostic Device for Detection of Multiple Cancer and Cardiac Disease Biomarkers
    Ceylan, Omer
    Mishra, Geetesh K.
    Yazici, Melik
    Cakmakci, Riza C.
    Niazi, Javed H.
    Qureshi, Anjum
    Gurbuz, Yasar
    2018 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2018,
  • [39] Emerging electrochemical nanoscale architectures for point-of-care detection of miRNA biomarkers
    Dastidar, Monalisha Ghosh
    Schumann, Ulrike
    Nisbet, David R.
    Natoli, Riccardo
    Murugappan, Krishnan
    Tricoli, Antonio
    CHEMICAL ENGINEERING JOURNAL, 2025, 508
  • [40] Detection of skin allergy biomarkers for point-of-care diagnosis of contact dermatitis
    Lefevre, M-A
    Nosbaum, A.
    Mosnier, A.
    Lenief, V.
    Salque, S.
    Pichot, M.
    Maheux, L.
    Bertolotti, L.
    Hacard, F.
    Graveriau, C.
    Zukervar, P.
    Guitarian, A-L Breton
    Boisleve, F.
    Elbaz, M.
    Nicolas, J-F
    Vocanson, M.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2023, 143 (11) : S369 - S369