Towards an Integrated System as Point-of-Care Device for the Optical Detection of Sepsis Biomarkers

被引:9
|
作者
Giannetti, Ambra [1 ]
Trono, Cosimo [1 ]
Porro, Giampiero [2 ]
Domenici, Claudio [3 ]
Puntoni, Mariarita [3 ]
Baldini, Francesco [1 ]
机构
[1] CNR, IFAC, Ist Fis Applicata Nello Carrara, Sesto Fiorentino 50019, FI, Italy
[2] DataMED Srl, Peschiera Garda 20068, MI, Italy
[3] CNR, IFC, Ist Fisiol Clin, Pisa 56124, Italy
基金
欧盟地平线“2020”;
关键词
C-reactive protein; neopterin; POCT; sepsis; immunoassay; biochip; fluorescence; C-REACTIVE PROTEIN; SERUM NEOPTERIN; PROCALCITONIN; BACTERIAL; LEVEL; SHOCK; RISK; UNIT;
D O I
10.3390/chemosensors8010012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Severe infection and sepsis are a common, expensive, and frequently fatal conditions in critically ill patients. The sepsis diagnosis is not trivial, since it is an extremely complex chain of events involving inflammatory and anti-inflammatory processes, cellular reactions, and circulatory disorders. For these reasons, delay in diagnosis and initiation of drug treatments have shown to be crucial for this pathology. Moreover, a multitude of biomarkers has been proposed, many more than for other pathologies. In order to select optimal treatments for the highly heterogeneous group of sepsis patients and to reduce costs, novel multiplexed tools that better characterize the patient and his or her specific immune response are highly desired. In order to achieve the fundament of drastically improved multi-analyte detection and to attain low limits of detection in diagnostics, the area of point-of-care testing (POCT) technology is developing quickly, leading to the production of instruments, the reliability of which is continuously increasing. For this purpose, a selection of two biomarkers-C-reactive protein (CRP) and neopterin (NP)-was studied in this paper and a fluorescence-based integrated optical system, suitable for future POCT applications, was implemented that is capable of performing the simultaneous measurement of the two different biomarkers in replicate. A limit of detection of 10 and 2.1 mu g L-1 was achieved for CRP and NP spiked in commercially available human serum, respectively. Moreover, measurements on both biomarkers were also performed on serum samples collected from septic patients.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Towards improved point-of-care (POC) testing for patients with suspected sepsis: POC tests for host biomarkers and possible microbial pathogens
    Adami, Maria-Evangelia
    Giamarellos-Bourboulis, Evangelos J.
    Polyzogopoulou, Effie
    EXPERT REVIEW OF MOLECULAR DIAGNOSTICS, 2024, 24 (09) : 829 - 839
  • [42] Miniaturized Protein Microarray with Internal Calibration as Point-of-Care Device for Diagnosis of Neonatal Sepsis
    Buchegger, Patricia
    Sauer, Ursula
    Toth-Szekely, Hedvig
    Preininger, Claudia
    SENSORS, 2012, 12 (02) : 1494 - 1508
  • [43] An integrated and automated electronic system for point-of-care protein testing
    Wu, D.
    Voldman, J.
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1571 - 1574
  • [44] Point-of-care device: a word of caution
    Bhagwat, A. G.
    Taneja, S.
    Singal, N.
    Narang, S.
    ANAESTHESIA AND INTENSIVE CARE, 2009, 37 (01) : 138 - 139
  • [45] Point-of-care device for Graves’ disease detection using Infrared Thermography
    Sharma, Vaishali
    Dhingra, Vandana K.
    Kumar, Ashok
    Goswami, Mayank
    e-Journal of Nondestructive Testing, 2022, 27 (11):
  • [46] An Instantaneous Low-Cost Point-of-Care Anemia Detection Device
    Punter-Villagrasa, Jaime
    Cid, Joan
    Paez-Aviles, Cristina
    Rodriguez-Villarreal, Ivon
    Juanola-Feliu, Esteve
    Colomer-Farrarons, Jordi
    Miribel-Catala, Pere Ll.
    SENSORS, 2015, 15 (02): : 4564 - 4577
  • [47] Integrated optical detection of autonomous capillary microfluidic immunoassays:a hand-held point-of-care prototype
    Novo, P.
    Chu, V.
    Conde, J. P.
    BIOSENSORS & BIOELECTRONICS, 2014, 57 : 284 - 291
  • [48] Optical sensing of anticoagulation status: Towards point-of-care coagulation testing
    Tshikudi, Diane M.
    Tripathi, Markandey M.
    Hajjarian, Zeinab
    Van Cott, Elizabeth M.
    Nadkarni, Seemantini K.
    PLOS ONE, 2017, 12 (08):
  • [49] An integrated microfluidic electrochemiluminescence device for point-of-care testing of acute myocardial infarction
    Zhu, Lihang
    Fu, Wenxuan
    Zhu, Boyu
    Feng, Qian
    Ying, Xudong
    Li, Shuang
    Chen, Jing
    Xie, Xiaoya
    Pan, Chenying
    Liu, Jun
    Chen, Chao
    Chen, Xing
    Zhu, Danhua
    TALANTA, 2023, 262
  • [50] Electrochemical point-of-care devices for the diagnosis of sepsis
    Valera, Enrique
    Kindratenko, Victoria
    Jankelow, Aaron M.
    Heredia, John
    Kim, Alicia Y.
    Cowell, Thomas W.
    Chen, Chih-Lin
    White, Karen
    Han, Hee-Sun
    Bashir, Rashid
    CURRENT OPINION IN ELECTROCHEMISTRY, 2023, 39