Reaerosolization of MS2 Bacteriophage from an N95 Filtering Facepiece Respirator by Simulated Coughing

被引:29
|
作者
Fisher, Edward M. [1 ]
Richardson, Aaron W. [2 ]
Harpest, Shannon D. [2 ]
Hofacre, Kent C. [2 ]
Shaffer, Ronald E. [1 ]
机构
[1] Natl Inst Occupat Safety & Hlth, Natl Personal Protect Technol Lab, Pittsburgh, PA 15236 USA
[2] Battelle Mem Inst, Columbus, OH 43201 USA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2012年 / 56卷 / 03期
关键词
infection control; influenza transmission; respiratory protection; INFLUENZA-A H5N1; PERFORMANCE; INFECTION; RISK; DECONTAMINATION; TRANSMISSION; VIRUSES; TUBERCULOSIS; CORONAVIRUS; PARTICLES;
D O I
10.1093/annhyg/mer101
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The supply of N95 filtering facepiece respirators (FFRs) may not be adequate to match demand during a pandemic outbreak. One possible strategy to maintain supplies in healthcare settings is to extend FFR use for multiple patient encounters; however, contaminated FFRs may serve as a source for the airborne transmission of virus particles. In this study, reaerosolization of virus particles from contaminated FFRs was examined using bacteriophage MS2 as a surrogate for airborne pathogenic viruses. MS2 was applied to FFRs as droplets or droplet nuclei. A simulated cough (370 l min(-1) peak flow) provided reverse airflow through the contaminated FFR. The number and size of the reaerosolized particles were measured using gelatin filters and an Andersen Cascade Impactor (ACI). Two droplet nuclei challenges produced higher percentages of reaerosolized particles (0.21 and 0.08%) than a droplet challenge (< 0.0001%). Overall, the ACI-determined size distribution of the reaerosolized particles was larger than the characterized loading virus aerosol. This study demonstrates that only a small percentage of viable MS2 viruses was reaerosolized from FFRs by reverse airflow under the conditions evaluated, suggesting that the risks of exposure due to reaerosolization associated with extended use can be considered negligible for most respiratory viruses. However, risk assessments should be updated as new viruses emerge and better workplace exposure data becomes available.
引用
收藏
页码:315 / 325
页数:11
相关论文
共 50 条
  • [41] Performance of an N95 Filtering Facepiece Particulate Respirator and a Surgical Mask During Human Breathing: Two Pathways for Particle Penetration
    Grinshpun, Sergey A.
    Haruta, Hiroki
    Eninger, Robert M.
    Reponen, Tiina
    Mckay, Roy T.
    Lee, Shu-An
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2009, 6 (10) : 593 - 603
  • [42] Effect of N95 filtering facepiece respirator on venous blood carbon dioxide levels and hemodynamic changes in health care workers
    Hussain, Sana Yasmin
    Khanuja, Samiksha
    Panjiar, Pratibha
    Jain, Dhruv
    Batt, Kharat Mohammad
    INDIAN JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2023, 27 (01) : 38 - 41
  • [43] The impact of extreme reuse and extended wear conditions on protection provided by a surgical-style N95 filtering facepiece respirator
    Duncan, Scott
    Bodurtha, Paul
    Bourgeois, Cara
    Dickson, Eva
    Jensen, Cheryl
    Naqvi, Syed
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2020, 17 (11-12) : 546 - 559
  • [44] Simulated Effects of Head Movement on Contact Pressures between Headforms and N95 Filtering Facepiece Respirators Part 2: Simulation
    Lei, Zhipeng
    Ji, Xuewu
    Li, Ning
    Yang, James
    Zhuang, Ziqing
    Rottach, Dana
    ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (09): : 1186 - 1199
  • [45] Pulmonary and heart rate responses to wearing N95 filtering facepiece respirators
    Kim, Jung-Hyun
    Benson, Stacey M.
    Roberge, Raymond J.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (01) : 24 - 27
  • [46] Evaluation of a quantitative fit testing method for N95 filtering facepiece respirators
    Janssen, L
    Luinenburg, MD
    Mullins, HE
    Danisch, SG
    Nelson, TJ
    AIHA JOURNAL, 2003, 64 (04): : 480 - 486
  • [47] Effectiveness of N95 Facepiece Respirators in Filtering Aerosol Following Storage and Sterilization
    Lin, Tzu-Hsien
    Tseng, Chun-Chieh
    Huang, Yu-Li
    Lin, Hsiu-Chuan
    Lai, Chane-Yu
    Lee, Shu-An
    AEROSOL AND AIR QUALITY RESEARCH, 2020, 20 (04) : 833 - 843
  • [48] Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
    Cho, Kyungmin Jacob
    Reponen, Tiina
    Mckay, Roy
    Shukla, Rakesh
    Haruta, Hiroki
    Sekar, Padmini
    Grinshpun, Sergey A.
    ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (01): : 68 - 77
  • [49] Evaluation of Sampling Probes for Fit Testing N95 Filtering Facepiece Respirators
    Bergman, Michael S.
    Viscusi, Dennis J.
    Zhuang, Ziqing
    Newcomb, William E.
    ANNALS OF OCCUPATIONAL HYGIENE, 2013, 57 (04): : 507 - 518
  • [50] Effect of Exhaled Moisture on Breathing Resistance of N95 Filtering Facepiece Respirators
    Roberge, Raymond J.
    Bayer, Emily
    Powell, Jeffrey B.
    Coca, Aitor
    Roberge, Marc R.
    Benson, Stacey M.
    ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (06): : 671 - 677