Reaerosolization of MS2 Bacteriophage from an N95 Filtering Facepiece Respirator by Simulated Coughing

被引:29
|
作者
Fisher, Edward M. [1 ]
Richardson, Aaron W. [2 ]
Harpest, Shannon D. [2 ]
Hofacre, Kent C. [2 ]
Shaffer, Ronald E. [1 ]
机构
[1] Natl Inst Occupat Safety & Hlth, Natl Personal Protect Technol Lab, Pittsburgh, PA 15236 USA
[2] Battelle Mem Inst, Columbus, OH 43201 USA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2012年 / 56卷 / 03期
关键词
infection control; influenza transmission; respiratory protection; INFLUENZA-A H5N1; PERFORMANCE; INFECTION; RISK; DECONTAMINATION; TRANSMISSION; VIRUSES; TUBERCULOSIS; CORONAVIRUS; PARTICLES;
D O I
10.1093/annhyg/mer101
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The supply of N95 filtering facepiece respirators (FFRs) may not be adequate to match demand during a pandemic outbreak. One possible strategy to maintain supplies in healthcare settings is to extend FFR use for multiple patient encounters; however, contaminated FFRs may serve as a source for the airborne transmission of virus particles. In this study, reaerosolization of virus particles from contaminated FFRs was examined using bacteriophage MS2 as a surrogate for airborne pathogenic viruses. MS2 was applied to FFRs as droplets or droplet nuclei. A simulated cough (370 l min(-1) peak flow) provided reverse airflow through the contaminated FFR. The number and size of the reaerosolized particles were measured using gelatin filters and an Andersen Cascade Impactor (ACI). Two droplet nuclei challenges produced higher percentages of reaerosolized particles (0.21 and 0.08%) than a droplet challenge (< 0.0001%). Overall, the ACI-determined size distribution of the reaerosolized particles was larger than the characterized loading virus aerosol. This study demonstrates that only a small percentage of viable MS2 viruses was reaerosolized from FFRs by reverse airflow under the conditions evaluated, suggesting that the risks of exposure due to reaerosolization associated with extended use can be considered negligible for most respiratory viruses. However, risk assessments should be updated as new viruses emerge and better workplace exposure data becomes available.
引用
收藏
页码:315 / 325
页数:11
相关论文
共 50 条
  • [21] The effect of simulated air conditions on N95 filtering facepiece respirators performance
    Ramirez, Joel A.
    O'Shaughnessy, Patrick T.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (07) : 491 - 500
  • [22] Assessing the impact of multiple ultraviolet disinfection cycles on N95 filtering facepiece respirator integrity
    C. Carolina Ontiveros
    Crystal L. Sweeney
    Christopher Smith
    Sean MacIsaac
    Jessica L. Bennett
    Sebastian Munoz
    Amina K. Stoddart
    Graham A. Gagnon
    Scientific Reports, 11
  • [23] Effects of UV-C Disinfection on N95 and KN95 Filtering Facepiece Respirator Reuse
    Bernardy, Castine
    Elardo, Nicola
    Trautz, Alexa
    Malley, Jim
    Wang, Diyuan
    Ducoste, Joel
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2022, 88 (19)
  • [24] Customized design and 3D printing of face seal for an N95 filtering facepiece respirator
    Cai, Mang
    Li, Hui
    Shen, Shengnan
    Wang, Yu
    Yang, Quan
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2018, 15 (03) : 226 - 234
  • [25] Thermal Burden of N95 Filtering Facepiece Respirators
    Roberge, Raymond
    Benson, Stacey
    Kim, Jung-Hyun
    ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (07): : 808 - 814
  • [26] Investigation of the flow-field in the upper respiratory system when wearing N95 filtering facepiece respirator
    Zhang, Xiaotie
    Li, Hui
    Shen, Shengnan
    Cai, Mang
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (05) : 372 - 382
  • [27] Effect of wearing an N95 filtering facepiece respirator on superomedial orbital infrared indirect brain temperature measurements
    Travis DiLeo
    Raymond J. Roberge
    Jung-Hyun Kim
    Journal of Clinical Monitoring and Computing, 2017, 31 : 67 - 73
  • [28] Estimating the Dead Space Volume Between a Headform and N95 Filtering Facepiece Respirator Using Microsoft Kinect
    Xu, Ming
    Lei, Zhipeng
    Yang, James
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2015, 12 (08) : 538 - 546
  • [29] Effect of wearing an N95 filtering facepiece respirator on superomedial orbital infrared indirect brain temperature measurements
    DiLeo, Travis
    Roberge, Raymond J.
    Kim, Jung-Hyun
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (01) : 67 - 73
  • [30] Evaluation of the Filtration Efficiency of the N95 Filtering Facepiece Respirator for Airborne Methicillin-Resistant Staphylococcus aureus
    Ferguson, D. D.
    Smith, T. C.
    Donham, K. J.
    O'Shaughnessy, P. T.
    JOURNAL OF AGRICULTURAL SAFETY AND HEALTH, 2014, 20 (04): : 255 - 265