Simulated Effects of Head Movement on Contact Pressures between Headforms and N95 Filtering Facepiece Respirators Part 2: Simulation

被引:12
|
作者
Lei, Zhipeng [1 ]
Ji, Xuewu [2 ]
Li, Ning [1 ]
Yang, James [1 ]
Zhuang, Ziqing [3 ]
Rottach, Dana [3 ]
机构
[1] Texas Tech Univ, Dept Mech Engn, Human Centr Design Res Lab, Lubbock, TX 79409 USA
[2] Tsinghua Univ, State Key Lab Automot Safety & Energy, Beijing 100084, Peoples R China
[3] NIOSH, Pittsburgh, PA 15236 USA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2014年 / 58卷 / 09期
关键词
finite element simulation; head movement; respirator contact pressure; HALF-MASK RESPIRATOR; LEAK SITES; PERFORMANCE;
D O I
10.1093/annhyg/meu064
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Finite element (FE) filtering facepiece respirators (FFRs) were developed and mated to the new headforms with a cervical spine model. The FFRs from three manufacturers included three sizing systems: (i) a single one-size-fits all, (ii) an FFR with two sizes (S/M and M/L), and (iii) an FFR with three sizes (S, L/M, XL). Finite element method (FEM) simulations of 16 headform and respirator combinations (5 headforms and 6 respirators) were used to examine maximum contact pressure changes for five cases: static head, flexion, extension, left rotation, and right rotation. For each of the 16 headform and respirator combinations, maximum contact pressures of the static headform and motile headforms were compared using t-tests. Significant differences on the maximum contact pressures were found in the extension, left rotation and right rotation at the nose (P < 0.005), the left rotation at the top of right cheek (P = 0.03), and the extension at the bottom of left/right cheek (P = 0.01). When separately considering each headform and each FFR manufacturer, the effects of the four head movement cases on the nose maximum contact pressure changes were observed in the simulations with all five headforms and all FFR manufacturers. The effects of the left and right rotations on the chin maximum contact pressure changes were observed in the simulations with the small headform. It was also found that the use of a nose clip could reduce the impact of the head left/right rotations on nose maximum contact pressure changes. In addition, head movements changed pressure contours of the key nose area. Caused by the head movements, the maximum contact pressure changes may affect seal quality, and the increase of the maximum contact pressures could reduce the facial comfort level.
引用
收藏
页码:1186 / 1199
页数:14
相关论文
共 50 条
  • [1] Simulated Effects of Head Movement on Contact Pressures Between Headforms and N95 Filtering Facepiece Respirators-Part 1: Headform Model and Validation
    Lei, Zhipeng
    Ji, Xuewu
    Li, Ning
    Yang, James
    Zhuang, Ziqing
    Rottach, Dana
    ANNALS OF OCCUPATIONAL HYGIENE, 2014, 58 (09): : 1175 - 1185
  • [2] The effect of simulated air conditions on N95 filtering facepiece respirators performance
    Ramirez, Joel A.
    O'Shaughnessy, Patrick T.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (07) : 491 - 500
  • [3] Thermal Burden of N95 Filtering Facepiece Respirators
    Roberge, Raymond
    Benson, Stacey
    Kim, Jung-Hyun
    ANNALS OF OCCUPATIONAL HYGIENE, 2012, 56 (07): : 808 - 814
  • [4] Multicycle Autoclave Decontamination of N95 Filtering Facepiece Respirators
    Bopp, Nathen E.
    Bouyer, Donald H.
    Gibbs, Christopher M.
    Nichols, Joan E.
    Ntiforo, Corrie A.
    Grimaldo, Miguel A.
    APPLIED BIOSAFETY, 2020, 25 (03) : 150 - 156
  • [5] Heat and Humidity for Bioburden Reduction of N95 Filtering Facepiece Respirators
    Anderegg, Loic
    Doyle, John
    Gardel, Margaret L.
    Gupta, Amit
    Hallas, Christian
    Lensky, Yuri
    Love, Nancy G.
    Lucas, Bronwyn A.
    Mazenc, Edward
    Meisenhelder, Cole
    Pillarisetti, Ajay
    Ranard, Daniel
    Squires, Allison H.
    Vechakul, Jessica
    Vilas, Nathaniel B.
    Williams, Stuart
    Wilson, Daniel
    Chen, Tyler N.
    APPLIED BIOSAFETY, 2021, 26 (02) : 80 - 89
  • [6] Fitting characteristics of eighteen N95 filtering-facepiece respirators
    Coffey, CC
    Lawrence, RB
    Campbell, DL
    Zhuang, ZQ
    Calvert, CA
    Jensen, PA
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2004, 1 (04) : 262 - 271
  • [7] Physiological and Thermoregulatory Responses to Wearing N95 Filtering Facepiece Respirators
    Kim, Jung-Hyun
    Roberge, Raymond J.
    Benson, Stacey M.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 319 - 319
  • [8] Hydrogen Peroxide Methods for Decontaminating N95 Filtering Facepiece Respirators
    Rempel, David
    Henneman, John
    Agalloco, James
    Crittenden, Jill
    APPLIED BIOSAFETY, 2021, 26 (02) : 71 - 79
  • [9] Evaluation of N95 Filtering Facepiece Respirators Challenged with Engineered Nanoparticles
    Zhou, Yue
    Cheng, Yung Sung
    AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (01) : 212 - 220
  • [10] Pulmonary and heart rate responses to wearing N95 filtering facepiece respirators
    Kim, Jung-Hyun
    Benson, Stacey M.
    Roberge, Raymond J.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2013, 41 (01) : 24 - 27