Reaerosolization of MS2 Bacteriophage from an N95 Filtering Facepiece Respirator by Simulated Coughing

被引:29
|
作者
Fisher, Edward M. [1 ]
Richardson, Aaron W. [2 ]
Harpest, Shannon D. [2 ]
Hofacre, Kent C. [2 ]
Shaffer, Ronald E. [1 ]
机构
[1] Natl Inst Occupat Safety & Hlth, Natl Personal Protect Technol Lab, Pittsburgh, PA 15236 USA
[2] Battelle Mem Inst, Columbus, OH 43201 USA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2012年 / 56卷 / 03期
关键词
infection control; influenza transmission; respiratory protection; INFLUENZA-A H5N1; PERFORMANCE; INFECTION; RISK; DECONTAMINATION; TRANSMISSION; VIRUSES; TUBERCULOSIS; CORONAVIRUS; PARTICLES;
D O I
10.1093/annhyg/mer101
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The supply of N95 filtering facepiece respirators (FFRs) may not be adequate to match demand during a pandemic outbreak. One possible strategy to maintain supplies in healthcare settings is to extend FFR use for multiple patient encounters; however, contaminated FFRs may serve as a source for the airborne transmission of virus particles. In this study, reaerosolization of virus particles from contaminated FFRs was examined using bacteriophage MS2 as a surrogate for airborne pathogenic viruses. MS2 was applied to FFRs as droplets or droplet nuclei. A simulated cough (370 l min(-1) peak flow) provided reverse airflow through the contaminated FFR. The number and size of the reaerosolized particles were measured using gelatin filters and an Andersen Cascade Impactor (ACI). Two droplet nuclei challenges produced higher percentages of reaerosolized particles (0.21 and 0.08%) than a droplet challenge (< 0.0001%). Overall, the ACI-determined size distribution of the reaerosolized particles was larger than the characterized loading virus aerosol. This study demonstrates that only a small percentage of viable MS2 viruses was reaerosolized from FFRs by reverse airflow under the conditions evaluated, suggesting that the risks of exposure due to reaerosolization associated with extended use can be considered negligible for most respiratory viruses. However, risk assessments should be updated as new viruses emerge and better workplace exposure data becomes available.
引用
收藏
页码:315 / 325
页数:11
相关论文
共 50 条
  • [1] Transfer of bacteriophage MS2 and fluorescein from N95 filtering facepiece respirators to hands: Measuring fomite potential
    Brady, Tyler M.
    Strauch, Amanda L.
    Almaguer, Claudia M.
    Niezgoda, George
    Shaffer, Ronald E.
    Yorio, Patrick L.
    Fisher, Edward M.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (11) : 898 - 906
  • [2] Filtering Facepiece Respirator (N95 Respirator) Reprocessing A Systematic Review
    Schumm, Max A.
    Hadaya, Joseph E.
    Mody, Nisha
    Myers, Bethany A.
    Maggard-Gibbons, Melinda
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (13): : 1296 - 1317
  • [3] N95 Filtering Facepiece Respirator Deadspace Temperature and Humidity
    Roberge, Raymond J.
    Kim, Jung-Hyun
    Benson, Stacey
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (03) : 166 - 171
  • [4] Workplace protection factors for an N95 filtering facepiece respirator
    Janssen, Larry L.
    Nelson, Thomas J.
    Cuta, Karen T.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2007, 4 (09) : 698 - 707
  • [5] Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
    Roberge, Raymond J.
    Coca, Aitor
    Williams, W. Jon
    Powell, Jeffrey B.
    Palmiero, Andrew J.
    RESPIRATORY CARE, 2010, 55 (05) : 569 - 577
  • [6] Contact Area Determination between a N95 Filtering Facepiece Respirator and a Headform
    Lei, Zhipeng
    Yang, Jingzhou
    DIGITAL HUMAN MODELING, 2011, 6777 : 119 - 128
  • [7] Evaluation of at-home methods for N95 filtering facepiece respirator decontamination
    Chen, T. X.
    Pinharanda, A.
    Steinemann, N. A.
    Yasuma-Mitobe, K.
    Lee, E.
    Hahn, J.
    Wu, L.
    Fanourakis, S.
    Peterka, D. S.
    Hillman, E. M. C.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [8] Evaluation of N95 Filtering Facepiece Respirator Efficiency with Cyclic and Constant Flows
    Bahloul, Ali
    Mahdavi, Alireza
    Haghighat, Fariborz
    Ostiguy, Claude
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2014, 11 (08) : 499 - 508
  • [9] WATER VAPOR CONDENSATION ON THE INNER SURFACE OF AN N95 FILTERING FACEPIECE RESPIRATOR
    Rao, Yu
    Li, Hui
    Shen, Shengnan
    Yang, Quan
    Zhang, Guoqing
    Zhang, Xiaotie
    Li, Mengfei
    Duan, Shuaichen
    HEAT TRANSFER RESEARCH, 2019, 50 (03) : 217 - 231
  • [10] Evaluation of at-home methods for N95 filtering facepiece respirator decontamination
    T. X. Chen
    A. Pinharanda
    N. A. Steinemann
    K. Yasuma-Mitobe
    E. Lee
    J. Hahn
    L. Wu
    S. Fanourakis
    D. S. Peterka
    E. M. C. Hillman
    Scientific Reports, 11