Workplace protection factors for an N95 filtering facepiece respirator

被引:40
|
作者
Janssen, Larry L.
Nelson, Thomas J.
Cuta, Karen T.
机构
[1] 3M Co, Occupat Hlth & Environm Safety Div, St Paul, MN 55144 USA
[2] NIHS Inc, Delaware, OH USA
关键词
filtering facepiece; respirator performance; WPF; workplace protection factor;
D O I
10.1080/15459620701517764
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study evaluated the workplace performance of an N95 filtering facepiece, air-purifying respirator in a steel foundry. Air samples were collected inside and outside respirators worn by workers who were properly trained and qualitatively fit tested. For most workers, three or four pairs of air samples were collected on each of 2 days. The 49 valid sample sets were analyzed for iron, silicon, and zirconium. Only iron was present in sufficient concentrations to perform workplace protection factor (WPF) calculations. Individual WPF measurements ranged from 5 to 753. The geometric mean of the distribution was 119 with a lower 5th percentile value of 19. Time-weighted average WPFs (WPFTWA) were also calculated for each day for each worker as an estimate of the protection an individual might receive with daily respirator use. The WPFTWA values ranged from 15 for the worker with the single WPF value of 5, to a high of 684. The distribution of WPFTWA hod a geometric mean of 120 and a lower 5th percentile of 22. Both data treatments indicate this respirator's performance was consistent with the assigned protection factor of 10 typically used for half facepiece respirators. The respirator provided adequate protection as used in this study. All contaminant concentrations inside the respirator were well below the relevant occupational exposure limits. Data collected also illustrate the dynamic nature of faceseal leakage in the workplace.
引用
收藏
页码:698 / 707
页数:10
相关论文
共 50 条
  • [1] Filtering Facepiece Respirator (N95 Respirator) Reprocessing A Systematic Review
    Schumm, Max A.
    Hadaya, Joseph E.
    Mody, Nisha
    Myers, Bethany A.
    Maggard-Gibbons, Melinda
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2021, 325 (13): : 1296 - 1317
  • [2] N95 Filtering Facepiece Respirator Deadspace Temperature and Humidity
    Roberge, Raymond J.
    Kim, Jung-Hyun
    Benson, Stacey
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (03) : 166 - 171
  • [3] Physiological Impact of the N95 Filtering Facepiece Respirator on Healthcare Workers
    Roberge, Raymond J.
    Coca, Aitor
    Williams, W. Jon
    Powell, Jeffrey B.
    Palmiero, Andrew J.
    RESPIRATORY CARE, 2010, 55 (05) : 569 - 577
  • [4] Contact Area Determination between a N95 Filtering Facepiece Respirator and a Headform
    Lei, Zhipeng
    Yang, Jingzhou
    DIGITAL HUMAN MODELING, 2011, 6777 : 119 - 128
  • [5] Evaluation of at-home methods for N95 filtering facepiece respirator decontamination
    Chen, T. X.
    Pinharanda, A.
    Steinemann, N. A.
    Yasuma-Mitobe, K.
    Lee, E.
    Hahn, J.
    Wu, L.
    Fanourakis, S.
    Peterka, D. S.
    Hillman, E. M. C.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [6] Evaluation of N95 Filtering Facepiece Respirator Efficiency with Cyclic and Constant Flows
    Bahloul, Ali
    Mahdavi, Alireza
    Haghighat, Fariborz
    Ostiguy, Claude
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2014, 11 (08) : 499 - 508
  • [7] WATER VAPOR CONDENSATION ON THE INNER SURFACE OF AN N95 FILTERING FACEPIECE RESPIRATOR
    Rao, Yu
    Li, Hui
    Shen, Shengnan
    Yang, Quan
    Zhang, Guoqing
    Zhang, Xiaotie
    Li, Mengfei
    Duan, Shuaichen
    HEAT TRANSFER RESEARCH, 2019, 50 (03) : 217 - 231
  • [8] Evaluation of at-home methods for N95 filtering facepiece respirator decontamination
    T. X. Chen
    A. Pinharanda
    N. A. Steinemann
    K. Yasuma-Mitobe
    E. Lee
    J. Hahn
    L. Wu
    S. Fanourakis
    D. S. Peterka
    E. M. C. Hillman
    Scientific Reports, 11
  • [9] N95 Filtering Facepiece Respirator Use during Pregnancy: A Systematic Review
    Roeckner, Jared T.
    Krstic, Nevena
    Sipe, Bradley H.
    Obican, Sarah G.
    AMERICAN JOURNAL OF PERINATOLOGY, 2020, 37 (10) : 995 - 1001
  • [10] N95 Filtering Facepiece Respirator Reuse, Extended Use, and Filtration Efficiency
    Wang, Ralph C.
    Addo, Newton
    Degesys, Nida F.
    Fahimi, Jahan
    Ford, James S.
    Rosenthal, Efrat
    Harris, Anna R.
    Yaffee, Anna Q.
    Peterson, Susan
    Rothmann, Richard E.
    Deangelis, John
    Tolia, Vaishal
    Shah, Manish N.
    Stephenson, Thomas B.
    Nogueira-Prewitt, Sheila J.
    Yoon, Katherine N.
    Fisher, Edward M.
    Raven, Maria C.
    JAMA NETWORK OPEN, 2024, 7 (10)