Field test investigation of the performance of corrosion inhibitors: a case study

被引:2
|
作者
Gharbi, Kheira [1 ]
Chouicha, Samira [2 ]
Kelland, Malcolm Andrew [3 ]
机构
[1] Dept Etud Thermodynam, Div Labs Sonatrach, Ave 1er Novembre, Boumerdes 35000, Algeria
[2] Univ Kasdi Merbah Ouargla, LPTPM, Ouargla 30000, Algeria
[3] Univ Stavanger, Fac Sci & Technol, Dept Chem Biosci & Environm Engn, N-4036 Stavanger, Norway
关键词
Corrosion; Raw gas; Inhibitors; Algerian gas field; Efficiency; CARBON-STEEL; OIL; CO2; PIPELINES;
D O I
10.1007/s13202-021-01287-y
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corrosion is considered one of the major problems that affect flow assurance during hydrocarbon production. This irreversible phenomenon has the ability to cause serious material failure in the oil and gas industry. Consequently, heavy capital and operational costs are required to prevent corrosion processes. Sweet corrosion of raw gas production facilities in an Algerian gas field manifests inside surface installations, which leads to gas production interruption and high intervention costs. To mitigate this type of corrosion, many methods can be applied such as the selection of appropriate materials, the injection of inhibitors, and the use of protective coating. In this work, the main points of gas production system that have been affected by corrosion and the inspection techniques used in the studied field were reviewed. Moreover, the efficiency of two types of two corrosion inhibitors (film-forming/neutralizing and film-forming chemicals) was studied by measuring the corrosion rate in the field and conducting chemical analyses on the produced water samples in the laboratory. The results of laboratory analyses regarding pH and iron content measurement point out that the injection of film-forming/neutralizing chemical significantly shifted the pH of the medium from acid to more neutral value and decreased the iron content, while the injection of film-forming inhibitor affected only the iron content by decreasing its tenor in the water samples. These results confirm the functions of each inhibitor to protect metal against internal corrosion. The comparison between the single- and double-function inhibitors reveals that the film-forming inhibitor (CK981DZ) outperforms the film-forming/ neutralizing chemical with an efficiency that exceeds 99% at low injection rate. Moreover, it provides good compatibility and stability all through its injection path. Meanwhile, the application of double function inhibitor (film-forming/neutralizing) significantly reduced the corrosion rate of carbon steel structures, but it involved the formation of deposits in the gas processing plant. The findings from this study can help give a better understanding of the methodology of corrosion inhibitor performance evaluation in real condition of gas production, also the criteria of inhibitor screening based on laboratory and field tests.
引用
收藏
页码:3879 / 3888
页数:10
相关论文
共 50 条
  • [41] Investigation of polysiloxane coatings as corrosion inhibitors of zinc surfaces
    Hansal, WEG
    Hansal, S
    Pölzler, M
    Kornherr, A
    Zifferer, G
    Nauer, GE
    SURFACE & COATINGS TECHNOLOGY, 2006, 200 (09): : 3056 - 3063
  • [42] NMR Investigation of Viscoelastic Surfactant Compatibility with Corrosion Inhibitors
    Afra, S.
    Samouei, H.
    Nasr-El-Din, H. A.
    SPE JOURNAL, 2021, 26 (03): : 1250 - 1260
  • [43] FIELD-TEST OF REINFORCEMENT CORROSION IN CONCRETE
    FIDJESTOL, P
    NILSEN, N
    JOURNAL OF THE AMERICAN CONCRETE INSTITUTE, 1980, 77 (05): : 380 - 380
  • [44] Case Study on Performance and Safety Test of Defibrillator Devices
    Golpaygani, Ali Tavakoli
    Movahedi, Mohammad Mehdi
    PROCEEDINGS OF THE 2016 INTERNATIONAL CONFERENCE ON ELECTRICAL, MECHANICAL AND INDUSTRIAL ENGINEERING (ICEMIE), 2016, 51 : 140 - 142
  • [45] Improving Power, Performance and Area with Test: A Case Study
    McLaurin, Teresa
    Lawrence, Ignatius P.
    2018 IEEE INTERNATIONAL TEST CONFERENCE (ITC), 2018,
  • [46] Field Test Study of Performance of Bored Piles in Collapsible Loess
    Wang, Xingwei
    Wang, Xu
    Li, Jiandong
    Liu, Deren
    Zhang, Yanjie
    Jiang, Daijun
    APPLIED SCIENCES-BASEL, 2023, 13 (24):
  • [47] CORROSION FATIGUE TESTING AS A METHOD OF EVALUATING CORROSION INHIBITORS IN OIL FIELD ENVIRONMENTS
    MCREYNOLDS, RF
    VENNETT, RM
    MATERIALS PERFORMANCE, 1975, 14 (01) : 23 - 27
  • [48] Applying corrosion inhibitors to metal surfaces in electrostatic field
    Altsybeeva, AI
    Burlov, VV
    Kuzinova, TM
    PROTECTION OF METALS, 2003, 39 (02): : 193 - 194
  • [49] Applying corrosion inhibitors to metal surfaces in electrostatic field
    Altsybeeva, A.I.
    Burlov, V.V.
    Kuzinova, T.M.
    Zashchita Metallov, 2003, 39 (02): : 217 - 218
  • [50] Applying Corrosion Inhibitors to Metal Surfaces in Electrostatic Field
    A. I. Altsybeeva
    V. V. Burlov
    T. M. Kuzinova
    Protection of Metals, 2003, 39 : 193 - 194