Field test investigation of the performance of corrosion inhibitors: a case study

被引:2
|
作者
Gharbi, Kheira [1 ]
Chouicha, Samira [2 ]
Kelland, Malcolm Andrew [3 ]
机构
[1] Dept Etud Thermodynam, Div Labs Sonatrach, Ave 1er Novembre, Boumerdes 35000, Algeria
[2] Univ Kasdi Merbah Ouargla, LPTPM, Ouargla 30000, Algeria
[3] Univ Stavanger, Fac Sci & Technol, Dept Chem Biosci & Environm Engn, N-4036 Stavanger, Norway
关键词
Corrosion; Raw gas; Inhibitors; Algerian gas field; Efficiency; CARBON-STEEL; OIL; CO2; PIPELINES;
D O I
10.1007/s13202-021-01287-y
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corrosion is considered one of the major problems that affect flow assurance during hydrocarbon production. This irreversible phenomenon has the ability to cause serious material failure in the oil and gas industry. Consequently, heavy capital and operational costs are required to prevent corrosion processes. Sweet corrosion of raw gas production facilities in an Algerian gas field manifests inside surface installations, which leads to gas production interruption and high intervention costs. To mitigate this type of corrosion, many methods can be applied such as the selection of appropriate materials, the injection of inhibitors, and the use of protective coating. In this work, the main points of gas production system that have been affected by corrosion and the inspection techniques used in the studied field were reviewed. Moreover, the efficiency of two types of two corrosion inhibitors (film-forming/neutralizing and film-forming chemicals) was studied by measuring the corrosion rate in the field and conducting chemical analyses on the produced water samples in the laboratory. The results of laboratory analyses regarding pH and iron content measurement point out that the injection of film-forming/neutralizing chemical significantly shifted the pH of the medium from acid to more neutral value and decreased the iron content, while the injection of film-forming inhibitor affected only the iron content by decreasing its tenor in the water samples. These results confirm the functions of each inhibitor to protect metal against internal corrosion. The comparison between the single- and double-function inhibitors reveals that the film-forming inhibitor (CK981DZ) outperforms the film-forming/ neutralizing chemical with an efficiency that exceeds 99% at low injection rate. Moreover, it provides good compatibility and stability all through its injection path. Meanwhile, the application of double function inhibitor (film-forming/neutralizing) significantly reduced the corrosion rate of carbon steel structures, but it involved the formation of deposits in the gas processing plant. The findings from this study can help give a better understanding of the methodology of corrosion inhibitor performance evaluation in real condition of gas production, also the criteria of inhibitor screening based on laboratory and field tests.
引用
收藏
页码:3879 / 3888
页数:10
相关论文
共 50 条
  • [31] Test of inhibitors for preventing corrosion of steel reinforcement in concrete
    Jano, Albana
    Lame, Alketa
    Kokalari, Efrosini
    OVIDIUS UNIVERSITY ANNALS OF CHEMISTRY, 2021, 32 (02) : 110 - 113
  • [32] Cooling Water Screening Test of Corrosion and Scale Inhibitors
    Sun, Mojie
    Lei, Yu
    Xi, Lijuan
    Liu, Yonghua
    Wang, Xu
    FRONTIER OF NANOSCIENCE AND TECHNOLOGY, 2011, 694 : 794 - +
  • [33] Test method and device for evaluation of volatile corrosion inhibitors
    Sieber, M.
    Lautner, S.
    Fassbender, F.
    INTERNATIONAL JOURNAL OF CORROSION AND SCALE INHIBITION, 2019, 8 (04): : 908 - 925
  • [34] Investigation of Diospyros Kaki L.f husk extracts as corrosion inhibitors and bactericide in oil field
    Zhang, Jie
    Song, Yingpan
    Su, Huijun
    Zhang, Li
    Chen, Gang
    Zhao, Jingrui
    CHEMISTRY CENTRAL JOURNAL, 2013, 7
  • [35] The Impact of Test Case Summaries on Bug Fixing Performance: An Empirical Investigation
    Panichella, Sebastiano
    Panichella, Annibale
    Beller, Moritz
    Zaidman, Andy
    Gall, Harald C.
    2016 IEEE/ACM 38TH INTERNATIONAL CONFERENCE ON SOFTWARE ENGINEERING (ICSE), 2016, : 547 - 558
  • [36] Field investigation of frazil jam evolution: A case study
    Sui, JY
    Karney, BW
    Sun, ZC
    Wang, DS
    JOURNAL OF HYDRAULIC ENGINEERING-ASCE, 2002, 128 (08): : 781 - 787
  • [37] Field Investigation of Frazil Jam Evolution: A Case Study
    Sui, Jueyi
    Karney, Bryan W.
    Sun, Zhaochu
    Wang, Desheng
    Journal of Hydraulic Engineering, 2002, 128 (08) : 781 - 787
  • [38] Corrosion inhibitors:: Design, performance, and computer simulations
    Duda, Y
    Govea-Rueda, R
    Galicia, M
    Beltrán, HI
    Zamudio-Rivera, LS
    JOURNAL OF PHYSICAL CHEMISTRY B, 2005, 109 (47): : 22674 - 22684
  • [39] INVESTIGATION OF STEEL CORROSION IN PICKLING SOLUTIONS - SOLUTIONS WITH INHIBITORS
    SEFAJA, J
    DERNIKOVIC, B
    MALINA, J
    LOVRECEK, B
    SURFACE TECHNOLOGY, 1983, 20 (03): : 247 - 263
  • [40] Investigation of Benzothiazole Derivatives as Corrosion Inhibitors for Mild Steel
    Parameswari, K.
    Chitra, S.
    Selvaraj, A.
    Brindha, S.
    Menaga, M.
    PORTUGALIAE ELECTROCHIMICA ACTA, 2012, 30 (02) : 89 - 98