Field test investigation of the performance of corrosion inhibitors: a case study

被引:2
|
作者
Gharbi, Kheira [1 ]
Chouicha, Samira [2 ]
Kelland, Malcolm Andrew [3 ]
机构
[1] Dept Etud Thermodynam, Div Labs Sonatrach, Ave 1er Novembre, Boumerdes 35000, Algeria
[2] Univ Kasdi Merbah Ouargla, LPTPM, Ouargla 30000, Algeria
[3] Univ Stavanger, Fac Sci & Technol, Dept Chem Biosci & Environm Engn, N-4036 Stavanger, Norway
关键词
Corrosion; Raw gas; Inhibitors; Algerian gas field; Efficiency; CARBON-STEEL; OIL; CO2; PIPELINES;
D O I
10.1007/s13202-021-01287-y
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Corrosion is considered one of the major problems that affect flow assurance during hydrocarbon production. This irreversible phenomenon has the ability to cause serious material failure in the oil and gas industry. Consequently, heavy capital and operational costs are required to prevent corrosion processes. Sweet corrosion of raw gas production facilities in an Algerian gas field manifests inside surface installations, which leads to gas production interruption and high intervention costs. To mitigate this type of corrosion, many methods can be applied such as the selection of appropriate materials, the injection of inhibitors, and the use of protective coating. In this work, the main points of gas production system that have been affected by corrosion and the inspection techniques used in the studied field were reviewed. Moreover, the efficiency of two types of two corrosion inhibitors (film-forming/neutralizing and film-forming chemicals) was studied by measuring the corrosion rate in the field and conducting chemical analyses on the produced water samples in the laboratory. The results of laboratory analyses regarding pH and iron content measurement point out that the injection of film-forming/neutralizing chemical significantly shifted the pH of the medium from acid to more neutral value and decreased the iron content, while the injection of film-forming inhibitor affected only the iron content by decreasing its tenor in the water samples. These results confirm the functions of each inhibitor to protect metal against internal corrosion. The comparison between the single- and double-function inhibitors reveals that the film-forming inhibitor (CK981DZ) outperforms the film-forming/ neutralizing chemical with an efficiency that exceeds 99% at low injection rate. Moreover, it provides good compatibility and stability all through its injection path. Meanwhile, the application of double function inhibitor (film-forming/neutralizing) significantly reduced the corrosion rate of carbon steel structures, but it involved the formation of deposits in the gas processing plant. The findings from this study can help give a better understanding of the methodology of corrosion inhibitor performance evaluation in real condition of gas production, also the criteria of inhibitor screening based on laboratory and field tests.
引用
收藏
页码:3879 / 3888
页数:10
相关论文
共 50 条
  • [21] Short-Duration Performance Acceptance Test of Parabolic Trough Solar Field: A Case Study
    Elmaihy, Ali
    El Weteedy, Ahmed
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2017, 139 (05):
  • [22] A TEST RIG FOR THE INVESTIGATION OF THE PERFORMANCE AND FLOW FIELD OF TESLA FRICTION TURBINES
    Schosser, Constantin
    Lecheler, Stefan
    Pfitzner, Michael
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 1B, 2014,
  • [23] Investigation of lignosulphonate mannich bases as corrosion inhibitors
    Hao, Hua-Rui
    Miao, Yan-Qing
    Open Chemical Engineering Journal, 2015, 9 (01): : 78 - 83
  • [24] Imidazole derivatives as corrosion inhibitors for copper: A DFT and reactive force field study
    Kumar, Dharmendr
    Jain, Vinay
    Rai, Beena
    CORROSION SCIENCE, 2020, 171
  • [25] Theoretical evaluation of corrosion inhibition performance of benzimidazole corrosion inhibitors
    Zhang Jun
    Zhao Wei-Min
    Guo Wen-Yue
    Wang Yong
    Li Zhong-Pu
    ACTA PHYSICO-CHIMICA SINICA, 2008, 24 (07) : 1239 - 1244
  • [26] Considerations in using laboratory test data as an indicator of field performance: Stress corrosion cracking
    Jones, RH
    ENVIRONMENTALLY ASSISTED CRACKING: PREDICTIVE METHODS FOR RISK ASSESSMENT AND EVALUATION OF MATERIALS, EQUIPMENT, AND STRUCTURES, 2000, 1401 : 259 - 272
  • [27] INVESTIGATION OF THE EFFECTIVENESS OF INHIBITORS OF MOISTURE CORROSION AND OF FILMS FORMED BY INHIBITORS ON STEELS
    APPEN, AA
    DEMCHENKO, VS
    SEMENYUK, VI
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1978, 51 (07): : 1498 - 1501
  • [28] Study on the Performance and Mechanism of Morpholine Salt Volatile Corrosion Inhibitors on Carbon Steel
    Zhao, Xiong
    Zhang, Junying
    Ma, Lu
    Wang, Wubin
    Zhang, Mingxing
    COATINGS, 2024, 14 (08)
  • [29] Operating principle of volatile corrosion inhibitors in the jar test
    Rymer, L-M
    Sieber, M.
    Lautner, S.
    Fassbender, F.
    21ST CHEMNITZ SEMINAR ON MATERIALS ENGINEERING, 2019, 480
  • [30] A COPPER ION DISPLACEMENT TEST FOR SCREENING CORROSION INHIBITORS
    HUGHES, WB
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1958, 213 (12): : 350 - 352