Non-Contrast Perfusion Detection with ARFI Variance of Acceleration (VoA) Imaging: Phantom and In Vivo Results

被引:0
|
作者
Varadarajan, Ramya [1 ]
Torres, Gabriela [1 ]
Hossain, Md. Murad [1 ]
Gallippi, Caterina M. [1 ]
机构
[1] Univ North Carolina & North Carolina State Univ, Joint Dept Biomed Engn, Chapel Hill, NC 27514 USA
关键词
ARFI imaging; perfusion detection; non-contrast imaging; IMPACT; TRACKING; VELOCITY; DISEASE;
D O I
10.1109/ultsym.2019.8926231
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Low blood SNR makes detecting small vessels, measuring slow flow rates, and assessing blood perfusion without contrast administration challenging. A potential approach is to use Variance of Acceleration (VoA) imaging, which has been demonstrated previously in humans in vivo for monitoring subcutaneous bleeding and delineating intraplaque hemorrhage. We hypothesize that, without the addition of contrast agents, VoA can detect slow flow in small vessels for perfusion assessment. Experiments were performed on an ATS 700-D 527 calibrated flow phantom (vessel diameter of 1 mm, flow rates of 0-53 cm/s) and in the surgically exteriorized right kidneys of 3 pigs (2M/1F, mean body weight of 74.4 +/- 9.3 kg) at baseline and after inducing ischemia. In the phantom, logVoA increased in the vessel with increasing flow rate, and it remained constant in the background. LogVoA values were higher in the background with versus without the ARF excitation. Similarly, logVoA values were higher in the vessel, particularly for flow rates < 12 cm/s, with versus without ARF excitation. Vessel CNR by logVoA was higher with versus without ARF excitation for flow rates < 12 cm/s, and CNR by logVoA was greater than CNR by power Doppler for all flow rates. Additionally, logVoA was statistically significantly greater at baseline than ischemia in all three in vivo pig kidneys. Finally, logVoA delineates a 1.25 mm-diameter vessel in a pig renal cortex in vivo, while power Doppler does not. These results suggest that logVoA could support contrast-free detection of slow blood flow in small vessels and in vivo perfusion assessment.
引用
收藏
页码:2252 / 2255
页数:4
相关论文
共 50 条
  • [21] DYNAMIC IMAGING OF TUMOR PERFUSION USING CONTRAST ENHANCED ULTRASOUND: IN VIVO RESULTS
    Du, Juan
    Ballard, John R.
    Choi, Jeunghwan
    Bischof, John C.
    Ebbini, Emad S.
    2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 49 - 52
  • [22] Combining adaptive demodulation with singular value decomposition filtering for improved non-contrast perfusion ultrasound imaging
    Tierney, Jaime E.
    George, Mark
    Coolbaugh, Crystal
    Towse, Theodore
    Byram, Brett C.
    MEDICAL IMAGING 2018: ULTRASONIC IMAGING AND TOMOGRAPHY, 2018, 10580
  • [23] Prognosis with non-contrast CT and CT Perfusion imaging in thrombolysis-treated acute ischemic stroke
    Chen, Xiaoyu
    Lin, Shushen
    Zhang, Xianxian
    Hu, Su
    Wang, Ximing
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 149
  • [24] Reproducibility of Renal Perfusion MR Imaging in Native and Transplanted Kidneys Using Non-Contrast Arterial Spin Labeling
    Artz, Nathan S.
    Sadowski, Elizabeth A.
    Wentland, Andrew L.
    Djamali, Arjang
    Grist, Thomas M.
    Seo, Songwon
    Fain, Sean B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (06) : 1414 - 1421
  • [25] Adaptive Independent Component Analysis-Based Clutter Filtering for Improved Non-Contrast Perfusion Ultrasound Imaging
    Tierney, Jaime
    Wilkes, Don
    Byram, Brett
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [26] Non-Contrast Renal Magnetic Resonance Imaging to Assess Perfusion and Corticomedullary Differentiation in Health and Chronic Kidney Disease
    Gillis, Keith A.
    McComb, Christie
    Patel, Rajan K.
    Stevens, Kathryn K.
    Schneider, Markus P.
    Radjenovic, Aleksandra
    Morris, Scott T. W.
    Roditi, Giles H.
    Delles, Christian
    Mark, Patrick B.
    NEPHRON, 2016, 133 (03) : 183 - 192
  • [27] Automated CT Perfusion Imaging Versus Non-contrast CT for Ischemic Core Assessment in Large Vessel Occlusion
    Anderson Chun On Tsang
    Stephanie Lenck
    Christopher Hilditch
    Patrick Nicholson
    Waleed Brinjikji
    Timo Krings
    Vitor M. Pereira
    Frank L. Silver
    Joanna D. Schaafsma
    Clinical Neuroradiology, 2020, 30 : 109 - 114
  • [28] Detection and size measurements of kidney stones on virtual non-contrast reconstructions derived from dual-layer computed tomography in an ex vivo phantom setup
    R. P. Reimer
    H. Zaytoun
    K. Klein
    K. Sonnabend
    S. Lennartz
    D. Zopfs
    A. Heidenreich
    D. Maintz
    N. Große Hokamp
    European Radiology, 2023, 33 : 2995 - 3003
  • [29] Detection and size measurements of kidney stones on virtual non-contrast reconstructions derived from dual-layer computed tomography in an ex vivo phantom setup
    Reimer, R. P.
    Zaytoun, H.
    Klein, K.
    Sonnabend, K.
    Lennartz, S.
    Zopfs, D.
    Heidenreich, A.
    Maintz, D.
    Hokamp, N. Grosse
    EUROPEAN RADIOLOGY, 2023, 33 (04) : 2995 - 3003
  • [30] Automated CT Perfusion Imaging Versus Non-contrast CT for Ischemic Core Assessment in Large Vessel Occlusion
    Tsang, Anderson Chun On
    Lenck, Stephanie
    Hilditch, Christopher
    Nicholson, Patrick
    Brinjikji, Waleed
    Krings, Timo
    Pereira, Vitor M.
    Silver, Frank L.
    Schaafsma, Joanna D.
    CLINICAL NEURORADIOLOGY, 2020, 30 (01) : 109 - 114