Non-Contrast Perfusion Detection with ARFI Variance of Acceleration (VoA) Imaging: Phantom and In Vivo Results

被引:0
|
作者
Varadarajan, Ramya [1 ]
Torres, Gabriela [1 ]
Hossain, Md. Murad [1 ]
Gallippi, Caterina M. [1 ]
机构
[1] Univ North Carolina & North Carolina State Univ, Joint Dept Biomed Engn, Chapel Hill, NC 27514 USA
关键词
ARFI imaging; perfusion detection; non-contrast imaging; IMPACT; TRACKING; VELOCITY; DISEASE;
D O I
10.1109/ultsym.2019.8926231
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Low blood SNR makes detecting small vessels, measuring slow flow rates, and assessing blood perfusion without contrast administration challenging. A potential approach is to use Variance of Acceleration (VoA) imaging, which has been demonstrated previously in humans in vivo for monitoring subcutaneous bleeding and delineating intraplaque hemorrhage. We hypothesize that, without the addition of contrast agents, VoA can detect slow flow in small vessels for perfusion assessment. Experiments were performed on an ATS 700-D 527 calibrated flow phantom (vessel diameter of 1 mm, flow rates of 0-53 cm/s) and in the surgically exteriorized right kidneys of 3 pigs (2M/1F, mean body weight of 74.4 +/- 9.3 kg) at baseline and after inducing ischemia. In the phantom, logVoA increased in the vessel with increasing flow rate, and it remained constant in the background. LogVoA values were higher in the background with versus without the ARF excitation. Similarly, logVoA values were higher in the vessel, particularly for flow rates < 12 cm/s, with versus without ARF excitation. Vessel CNR by logVoA was higher with versus without ARF excitation for flow rates < 12 cm/s, and CNR by logVoA was greater than CNR by power Doppler for all flow rates. Additionally, logVoA was statistically significantly greater at baseline than ischemia in all three in vivo pig kidneys. Finally, logVoA delineates a 1.25 mm-diameter vessel in a pig renal cortex in vivo, while power Doppler does not. These results suggest that logVoA could support contrast-free detection of slow blood flow in small vessels and in vivo perfusion assessment.
引用
收藏
页码:2252 / 2255
页数:4
相关论文
共 50 条
  • [41] The value of non-contrast harmonic transthoracic echocardiography for the detection of left ventricular thrombi in patients with cardiomyopathy:: comparison with contrast-enhanced magnetic resonance imaging
    Lipke, Claudia
    Katoh, Marcus
    Franke, Andreas
    Krombach, Gabriele
    Buecker, Arno
    Kuehl, Harald P.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (04): : 479 - 487
  • [42] The value of non-contrast harmonic transthoracic echocardiography for the detection of left ventricular thrombi in patients with cardiomyopathy: comparison with contrast-enhanced magnetic resonance imaging
    Claudia Lipke
    Marcus Katoh
    Andreas Franke
    Gabriele Krombach
    Arno Buecker
    Harald P. Kühl
    The International Journal of Cardiovascular Imaging, 2007, 23 : 479 - 487
  • [43] Dual-Energy Computed Tomography in Stroke Imaging: Value of Virtual Non-Contrast Images for Detection of the Hyperdense Artery Sign
    Winklhofer, S.
    De Martini, V.
    Nern, Ch
    Blume, I.
    Wegener, S.
    Pangalu, A.
    Valavanis, A.
    Alkadhi, H.
    Guggenberger, R.
    SWISS MEDICAL WEEKLY, 2016, 146 : 172S - 173S
  • [44] Detection of ventricular thrombi via electron density imaging in non-contrast spectral computed tomography performed to exclude pneumonia: a case report
    Mochizuki, Junji
    Nakaura, Takeshi
    Hashimoto, Katsushi
    Hata, Yoshiki
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2022, 6 (04)
  • [45] Non-contrast versus contrast transthoracic echocardiography for the detection of left ventricular thrombus, using cardiac magnetic resonance imaging as a reference - a systematic review and meta-analysis
    Phuah, Yu Zhi
    Ahmad, Mahmood
    Sim, Sharmaine
    Tan, Ying Xin
    Wong, Joshua
    HEART, 2023, 109 : A208 - A210
  • [46] Quantitative assessment of myocardial perfusion in rat myocardium in vivo at rest and coronary dilation: A non contrast agent NMR imaging technique
    Waller, CM
    Kahler, E
    Belle, V
    Hiller, KHH
    Voll, S
    Hu, K
    Haase, A
    Bauer, WR
    CIRCULATION, 1998, 98 (17) : 858 - 858
  • [47] Detection of recurrent hepatocellular carcinoma after surgical resection: Non-contrast liver MR imaging with diffusion-weighted imaging versus gadoxetic acid-enhanced MR imaging
    Min, Ji Hye
    Kim, Young Kon
    Choi, Seo-Youn
    Kang, Tae Wook
    Jeong, Woo Kyoung
    Kim, Kyunga
    Won, Ho-Jeong
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1090):
  • [48] Integration of Non-Contrast Cardiac Computed Tomography and Stress Myocardial Perfusion Imaging in the Emergency Department: Identifying Which Patients with Chest Pain Can be Safely Discharged Home
    Nabi, Faisal
    Chang, Su Min
    Moye, Lemuel A.
    Hust, Robert G.
    Pratt, Craig M.
    Mahmarian, John J.
    CIRCULATION, 2008, 118 (18) : S1061 - S1061
  • [49] Integration of non-contrast cardiac computed tomography and stress myocardial perfusion imaging in the emergency department: Identifying which patients with chest pain can be safely discharged home
    Nabi, F.
    Chang, S. M.
    Moye, L. A.
    Hust, R. G.
    Pratt, C. M.
    Mahmarian, John J. J. J.
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2009, 11 (0B) : S44 - S44
  • [50] Comparison of automated infarct core volume measures between non-contrast computed tomography and perfusion imaging in acute stroke code patients evaluated for potential endovascular treatment
    Suomalainen, Olli P.
    Abou Elseoud, Ahmed
    Martinez-Majander, Nicolas
    Tiainen, Marjaana
    Forss, Nina
    Curtze, Sami
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2021, 426