Registration of emission and transmission whole-body scintillation-camera images

被引:0
|
作者
Sjögreen, K
Ljungberg, M
Wingårdh, K
Erlandsson, K
Strand, SE
机构
[1] Lund Univ, Univ Hosp, Jubileum Inst, Dept Radiat Phys, SE-22185 Lund, Sweden
[2] Middlesex Hosp, Inst Nucl Med, London W1N 8AA, England
关键词
whole-body image registration; conjugate view; planar activity quantification; mutual information;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an Image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. Methods: Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an I-131-labeled monoclonal antibody and for Monte Carlo-simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. Results: For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 10(5) (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 +/- 5 mm. Conclusion: An automatic registration method for WB images has been developed, which is applicable to emission-emission and transmission-emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.
引用
收藏
页码:1563 / 1570
页数:8
相关论文
共 50 条
  • [31] COMPUTERIZED WHOLE-BODY CAMERA DATA ACQUISITION AND DISPLAY
    DOBBELEIR, A
    FROIDEVILLE, JL
    ERBSMANN, F
    NECOSTRE, P
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1976, 1 (02): : 76 - 76
  • [32] EVALUATION OF A WHOLE-BODY CAMERA SYSTEM FOR BONE IMAGING
    SERAFINI, A
    ZAND, L
    SANKEY, R
    SMOAK, W
    [J]. SOUTHERN MEDICAL JOURNAL, 1973, 66 (11) : 1338 - 1338
  • [33] PERFORMANCE OF A HIGH SENSITIVITY LIQUID SCINTILLATION WHOLE-BODY COUNTER
    PRINGLE, DH
    BARNABY, CF
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (06): : 695 - &
  • [34] PERFORMANCE OF A HIGH SENSITIVITY LIQUID SCINTILLATION WHOLE-BODY COUNTER
    BARNABY, CF
    JASANI, BM
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1968, 1 (02): : 91 - &
  • [35] A clinical evaluation of the quantitative accuracy of simultaneous emission/transmission scanning in whole-body positron emission tomography
    Martin A. Lodge
    Ramsey D. Badawi
    Paul K. Marsden
    [J]. European Journal of Nuclear Medicine, 1998, 25 : 417 - 423
  • [36] A clinical evaluation of the quantitative accuracy of simultaneous emission/transmission scanning in whole-body positron emission tomography
    Lodge, MA
    Badawi, RD
    Marsden, PK
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (04) : 417 - 423
  • [37] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, Thomas
    Kinahan, Paul E.
    Townsend, David W.
    [J]. IEEE Transactions on Nuclear Science, 1997, 44 (6 pt 2): : 2400 - 2407
  • [38] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, T
    Kinahan, PE
    Townsend, DW
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1362 - 1366
  • [39] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, T
    Kinahan, PE
    Townsend, DW
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2400 - 2407
  • [40] Explicit incorporation of prior anatomical information into a nonrigid registration of thoracic and abdominal CT and 18-FDG whole-body emission PET images
    Camara, Oscar
    Delso, Gaspar
    Colliot, Olivier
    Moreno-Ingelmo, Antonio
    Bloch, Isabelle
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (02) : 164 - 178