Registration of emission and transmission whole-body scintillation-camera images

被引:0
|
作者
Sjögreen, K
Ljungberg, M
Wingårdh, K
Erlandsson, K
Strand, SE
机构
[1] Lund Univ, Univ Hosp, Jubileum Inst, Dept Radiat Phys, SE-22185 Lund, Sweden
[2] Middlesex Hosp, Inst Nucl Med, London W1N 8AA, England
关键词
whole-body image registration; conjugate view; planar activity quantification; mutual information;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this work, a method for registration of whole-body (WB) scintillation-camera images is presented. The primary motive for the development is to perform activity quantification using the conjugate view method on an Image basis. Accurate image registration is required for sequential anterior and posterior scans, for serial emission images for analysis of the biokinetics, and for transmission and emission images for a pixel-based attenuation correction. Methods: Registration is performed by maximization of the mutual information. The spatial transformation has been tailored for the registration of WB images and is composed of global and local transformations, including rigid, projective, and curved transformations. A coarse registration is first performed using cross-correlation and direct pixel scaling. Optimization is then performed in a sequence, beginning with the 2 legs independently, followed by the upper body and head. Evaluation is performed for clinical images of an I-131-labeled monoclonal antibody and for Monte Carlo-simulated images. An anthropomorphic WB computer phantom, which has been especially modified to match the patient position during WB scanning, is used for the simulations. Results: For simulated images, registration errors are within 1 pixel (<3.6 mm) for a sufficient image count level. Separate evaluation of the influence of noise shows that the errors increase below a total image count of approximately 10(5) (signal-to-noise ratio, approximately 4). For clinical evaluations, the deviations between point markers are 9 +/- 5 mm. Conclusion: An automatic registration method for WB images has been developed, which is applicable to emission-emission and transmission-emission registration. This method has been applied in more than 50 clinical studies and has shown to be robust and reliable.
引用
收藏
页码:1563 / 1570
页数:8
相关论文
共 50 条
  • [21] A new method to obtain transmission images for planar whole-body activity quantification
    Minarik, D
    Sjögreen, K
    Ljungberg, M
    [J]. CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2005, 20 (01) : 72 - 76
  • [22] Optimization of transmission and emission scan duration in whole-body PET imaging.
    Beyer, T
    Kinahan, PE
    Townsend, DW
    AbellaColumna, E
    Martinez, M
    Valk, PE
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 839 - 839
  • [23] NEW WHOLE-BODY SCANNER - COMPARISON WITH A LARGE CRYSTAL SCANNING CAMERA IN ORGAN AND WHOLE-BODY MODE
    ELL, PJ
    MYERS, M
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1976, 1 (02): : 75 - 75
  • [24] A hybrid registration-based method for whole-body micro-CT mice images
    Xiaochao Qu
    Xueyuan Gao
    Xianhui Xu
    Shouping Zhu
    Jimin Liang
    [J]. Medical & Biological Engineering & Computing, 2016, 54 : 1037 - 1048
  • [25] Average volume reference space for large scale registration of whole-body magnetic resonance images
    Pilia, Martino
    Kullberg, Joel
    Ahlstrom, Hakan
    Malmberg, Filip
    Ekstrom, Simon
    Strand, Robin
    [J]. PLOS ONE, 2019, 14 (10):
  • [26] A hybrid registration-based method for whole-body micro-CT mice images
    Qu, Xiaochao
    Gao, Xueyuan
    Xu, Xianhui
    Zhu, Shouping
    Liang, Jimin
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (07) : 1037 - 1048
  • [27] METHOD FOR INVESTIGATION OF GASTRIC EMPTYING BY MEANS OF AN IN-113M EMITTER, SCINTILLATION CAMERA AND WHOLE-BODY SCANNER
    SILAR, J
    SKALA, I
    MIKUSOVA, M
    KRAJSKA, V
    PROKOPEC, J
    SMIDOVA, M
    MOTTL, V
    PIRK, F
    SKALA, J
    [J]. REVIEW OF CZECHOSLOVAK MEDICINE, 1974, 20 (04): : 189 - 200
  • [28] USE OF A GAMMA-CAMERA AS A WHOLE-BODY COUNTER
    RICHARDS, AR
    SHORT, MD
    GLASS, HI
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1970, 43 (508): : 287 - &
  • [29] USE OF A GAMMA-CAMERA AS A WHOLE-BODY COUNTER
    SHORT, MD
    GLASS, HI
    RICHARDS, AR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (532): : 289 - &
  • [30] COLLIMATOR APERTURE OF ANGER CAMERA FOR WHOLE-BODY IMAGING
    WAGGETT, DJ