A new device to measure upper limb circumferences: validity and reliability

被引:0
|
作者
Devoogdt, N. [1 ,2 ,3 ]
Lemkens, H. [1 ,2 ]
Geraerts, I. [1 ,2 ]
Van Nuland, J. [1 ,2 ]
Flour, M. [4 ]
Coremans, T. [3 ]
Christiaens, M. R. [5 ]
Van Kampen, M. [1 ,2 ]
机构
[1] Univ Hosp Leuven, Dept Physiotherapy, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Fac Kinesiol & Rehabil Sci, Leuven, Belgium
[3] Univ Coll Antwerp, Dept Hlth Care Sci, Antwerp, Belgium
[4] Univ Hosp Leuven, Vasc Ctr, Louvain, Belgium
[5] Univ Hosp Leuven, Multidisciplinary Breast Ctr, Louvain, Belgium
关键词
Arm circumference; Measurements; Validation study; UPPER-EXTREMITY VOLUME; WATER DISPLACEMENT; LYMPHEDEMA; AGREEMENT; WOMEN;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aim. The aim of this paper was to examine the reliability and validity of a new measurement device that counters the disadvantages of the traditional method of arm circumference measurements. Methods. We measured the arm on the non-operated side of breast cancer patients. Sixty-four patients were measured twice by the same assessor and 48 patients were measured twice by two different assessors. The arm circumferences were measured at the olecranon and each 4 cm proximal and distal of the olecranon. The measurements were performed with a self-developed device consisting of a stainless steel bar on which a tapeline was fixed at every 4 cm distance. The arm volume was calculated from the circumference measurements with the frustrum formula and was also measured directly with the water displacement method. Results. For the circumference measurements, intrarater and interrater ICCs ranged between 0.942 and 0.998. ICCs for the calculated arm volume were also very high. No systematic changes between the first to the second assessment could be found. The standard error of measurement for the circumference measurements as well as for the calculated arm volume was low (between 0.8% and 2.0%). An increase of 1.0 cm or more of the arm circumference at any measurement side and of 55 ml or more of the calculated arm volume was clinically significant. Conclusion. Arm circumferences and also the calculated arm volume can be measured quickly and accurately with a simple and inexpensive device. [Int Angiol 2010;29:401-7]
引用
收藏
页码:401 / 407
页数:7
相关论文
共 50 条
  • [1] Evaluation Of Reliability And Validity Of A New Device To Measure Knee Rotation
    Masegi, Seiya
    Miyakawa, Shunpei
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 37 - 37
  • [2] A new test to measure upper limb apraxia (TULIAS): A reliability study
    Van Hemelrijk, B.
    Vanbellingen, T.
    Van de Winckel, A.
    De Weerdt, W.
    Bohlhalter, S.
    MOVEMENT DISORDERS, 2007, 22 : S213 - S214
  • [3] Validity and Reliability of a New Device to Measure Type of Actions in Indoor Sports
    Lago-Fuentes, Carlos
    Aiello, Paolo
    Testa, Mauro
    Munoz, Iker
    Mecias Calvo, Marcos
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2021, 42 (03) : 253 - 258
  • [4] Reliability and validity of a new device to measure isometric strength in polyarticular exercises
    Verdera, F
    Champavier, L
    Schmidt, C
    Bermon, S
    Marconnet, P
    JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS, 1999, 39 (02): : 113 - 119
  • [5] Structural validity and reliability of the patient experience measure: A new approach to assessing psychosocial experience of upper limb prosthesis users
    Resnik, Linda J.
    Borgia, Mathew L.
    Clark, Melissa A.
    Graczyk, Emily
    Segil, Jacob
    Ni, Pengsheng
    PLOS ONE, 2021, 16 (12):
  • [6] RELIABILITY AND VALIDITY OF A DEVICE TO MEASURE MUSCLE HARDNESS
    Kato, Gohei
    Andrew, Paul D.
    Sato, Haruhiko
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2004, 4 (02) : 213 - 225
  • [7] Upper Limb Spasticity Evaluation Based on Stretch Reflex Threshold: Method, Device, Validity and Reliability
    Hu B.-H.
    Mu J.-S.
    Zhu Z.-J.
    Zhao P.-P.
    Wang Y.
    Wang, Yong (simenkouwang@sina.com), 2018, Science Press (44): : 129 - 139
  • [8] The "upper limb rotation test": Reliability and validity study of a new upper extremity physical performance test
    Decleve, Ph
    Attar, T.
    Benameur, T.
    Gaspar, V
    Van Cant, J.
    Cools, Ann M.
    PHYSICAL THERAPY IN SPORT, 2020, 42 : 118 - 123
  • [9] Reliability, Validity, and Responsiveness of the QuickDASH in Patients With Upper Limb Amputation
    Resnik, Linda
    Borgia, Matthew
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (09): : 1676 - 1683
  • [10] Reliability, validity and discriminant ability of the instrumental indices provided by a novel planar robotic device for upper limb rehabilitation
    Germanotta, Marco
    Cruciani, Arianna
    Pecchioli, Cristiano
    Loreti, Simona
    Spedicato, Albino
    Meotti, Matteo
    Mosca, Rita
    Speranza, Gabriele
    Cecchi, Francesca
    Giannarelli, Giorgia
    Padua, Luca
    Aprile, Irene
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2018, 15