A new device to measure upper limb circumferences: validity and reliability

被引:0
|
作者
Devoogdt, N. [1 ,2 ,3 ]
Lemkens, H. [1 ,2 ]
Geraerts, I. [1 ,2 ]
Van Nuland, J. [1 ,2 ]
Flour, M. [4 ]
Coremans, T. [3 ]
Christiaens, M. R. [5 ]
Van Kampen, M. [1 ,2 ]
机构
[1] Univ Hosp Leuven, Dept Physiotherapy, B-3000 Louvain, Belgium
[2] Katholieke Univ Leuven, Fac Kinesiol & Rehabil Sci, Leuven, Belgium
[3] Univ Coll Antwerp, Dept Hlth Care Sci, Antwerp, Belgium
[4] Univ Hosp Leuven, Vasc Ctr, Louvain, Belgium
[5] Univ Hosp Leuven, Multidisciplinary Breast Ctr, Louvain, Belgium
关键词
Arm circumference; Measurements; Validation study; UPPER-EXTREMITY VOLUME; WATER DISPLACEMENT; LYMPHEDEMA; AGREEMENT; WOMEN;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Aim. The aim of this paper was to examine the reliability and validity of a new measurement device that counters the disadvantages of the traditional method of arm circumference measurements. Methods. We measured the arm on the non-operated side of breast cancer patients. Sixty-four patients were measured twice by the same assessor and 48 patients were measured twice by two different assessors. The arm circumferences were measured at the olecranon and each 4 cm proximal and distal of the olecranon. The measurements were performed with a self-developed device consisting of a stainless steel bar on which a tapeline was fixed at every 4 cm distance. The arm volume was calculated from the circumference measurements with the frustrum formula and was also measured directly with the water displacement method. Results. For the circumference measurements, intrarater and interrater ICCs ranged between 0.942 and 0.998. ICCs for the calculated arm volume were also very high. No systematic changes between the first to the second assessment could be found. The standard error of measurement for the circumference measurements as well as for the calculated arm volume was low (between 0.8% and 2.0%). An increase of 1.0 cm or more of the arm circumference at any measurement side and of 55 ml or more of the calculated arm volume was clinically significant. Conclusion. Arm circumferences and also the calculated arm volume can be measured quickly and accurately with a simple and inexpensive device. [Int Angiol 2010;29:401-7]
引用
收藏
页码:401 / 407
页数:7
相关论文
共 50 条
  • [21] Reliability of the Inverse Water Volumetry Method to Measure the Volume of the Upper Limb
    Beek, Martinus A.
    te Slaa, Alexander
    van der Laan, Lijckle
    Mulder, Paul G. H.
    Rutten, Harm J. T.
    Voogd, Adri C.
    Luiten, Ernest J. T.
    Gobardhan, Paul D.
    LYMPHATIC RESEARCH AND BIOLOGY, 2015, 13 (02) : 126 - 130
  • [22] RELIABILITY OF A NEW DEVICE TO MEASURE SHOULDER SUBLUXATION
    HAYES, KH
    SULLIVAN, JE
    PHYSICAL THERAPY, 1988, 68 (05): : 828 - 828
  • [23] Reliability and Validity of the Kinematic Dystonia Measure for Children With Upper Extremity Dystonia
    Kawamura, Anne
    Klejman, Sue
    Fehlings, Darcy
    JOURNAL OF CHILD NEUROLOGY, 2012, 27 (07) : 907 - 913
  • [24] Validity and Reliability of a New Method to Measure Cervical Proprioception
    Koseoglu, Aygul
    Coskunsu, Dilber Karagozoglu
    Mutlu, Ebru Kaya
    PHYSIKALISCHE MEDIZIN REHABILITATIONSMEDIZIN KURORTMEDIZIN, 2022, 32 (05) : 306 - 313
  • [26] Validity and reliability of the LEMOCOT in the adult ARSACS population: A measure of lower limb coordination
    Lessard, Isabelle
    Lavoie, Caroline
    Cote, Isabelle
    Mathieu, Jean
    Brais, Bernard
    Gagnon, Cynthia
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2017, 377 : 193 - 196
  • [27] Reliability and validity of a new scale to measure prejudice: The GRISMS
    Godfrey, S
    Richman, CL
    Withers, TN
    CURRENT PSYCHOLOGY, 2000, 19 (01) : 3 - 20
  • [28] Reliability and validity of a new scale to measure prejudice: The GRISMS
    Sherry Godfrey
    Charles L. Richman
    Taryn N. Withers
    Current Psychology, 2000, 19 : 3 - 20
  • [29] The reliability and validity of a new measure of severity of delirium.
    McCusker, J
    Cole, M
    Bellavance, F
    Primeau, F
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1997, 45 (09) : P267 - P267
  • [30] Validity and reliability of a novel device for bilateral upper extremity functional measurements
    Lin, Chueh-Ho
    Chou, Li-Wei
    Wei, Shun-Hwa
    Lieu, Fu-Kong
    Chiang, Shang-Lin
    Sung, Wen-Hsu
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2014, 114 (03) : 315 - 323