Reliability, Validity, and Responsiveness of the QuickDASH in Patients With Upper Limb Amputation

被引:32
|
作者
Resnik, Linda [1 ,2 ]
Borgia, Matthew [1 ]
机构
[1] Providence Vet Adm Med Ctr, Providence, RI USA
[2] Brown Univ, Hlth Serv Policy & Practice, Providence, RI 02912 USA
来源
关键词
Amputation; Disability evaluation; Psychometrics; Rehabilitation; COMPUTER-ADAPTIVE TEST; COMMUNITY REINTEGRATION; SHOULDER; ARM; HAND; DISABILITIES; DASH; QUESTIONNAIRE; DISORDERS; ORTHOTICS;
D O I
10.1016/j.apmr.2015.03.023
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objectives: To examine the internal consistency, test-retest reliability, validity, and responsiveness of the shortened version of the Disabilities of the Arm, Shoulder and Hand (QuicicDASH) questionnaire in persons with upper limb amputation. Design: Cross-sectional and longitudinal. Setting: Three sites participating in the U.S. Department of Veterans Affairs Home Study of the DEKA Arm. Participants: A convenience sample of upper limb amputees (N=44). Interventions: Training with a multifunction upper limb prosthesis. Main Outcome Measures: Multiple outcome measures including the QuickDASH were administered twice within 1 week, and for a subset of 20 persons, after completion of in-laboratory training with the DEKA Arm. Scale alphas and intraclass correlation coefficient type 3,1 (ICC3,1) were used to examine reliability. Minimum detectable change (MDC) scores were calculated. Analyses of variance, comparing QuickDASH scores by the amount of prosthetic use and amputation level, were used for known-group validity analyses with alpha set at .05. Pairwise correlations between QuicicDASH and other measures were used to examine concurrent validity. Responsiveness was measured by effect size (ES) and standardized response mean (SRM). Results: QuicicDASH alpha was .83, and ICC was .87 (95% confidence interval, .77-.93). MDC at the 95% confidence level (MDC95%) was 17.4. Full- or part-time prosthesis users had better QuicicDASH scores compared with nonprosthesis users (P=.021), as did those with more distal amputations at both baseline (P=.042) and with the DEKA Arm (P=.024). The QuicicDASH was correlated with concurrent measures of activity limitation as expected. The ES and SRM after training with the DEKA Arm were 0.6. Conclusions: This study provides evidence of reliability and validity of the QuickDASH in persons with upper limb amputation. Results provide preliminary evidence of responsiveness to prosthetic device type/training. Further research with a larger sample is needed to confirm results. (C) 2015 by the American Congress of Rehabilitation Medicine
引用
收藏
页码:1676 / 1683
页数:8
相关论文
共 50 条
  • [1] Reliability, validity and responsiveness of Brazilian version of QuickDASH
    da Silva, Natalia Claro
    Chaves, Thais Cristina
    dos Santos, Jacqueline Brazao
    Mendes Sugano, Raquel Metzker
    Barbosa, Rafael I.
    Marcolino, Alexandre M.
    Mazzer, Nilton
    Registro Fonseca, Marisa C.
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2020, 48
  • [2] Concurrent validity study of QuickDASH with respect to DASH in patients with traumatic upper extremity amputation
    Joonas Pyörny
    Ida Neergård Sletten
    Jarkko Jokihaara
    BMC Musculoskeletal Disorders, 25
  • [3] Concurrent validity study of QuickDASH with respect to DASH in patients with traumatic upper extremity amputation
    Pyorny, Joonas
    Sletten, Ida Neergard
    Jokihaara, Jarkko
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [4] The upper limb functional index: Development and determination of reliability, validity, and responsiveness
    Gabel, C. Philip
    Michener, Lori A.
    Burkett, Brendan
    Neller, Anne
    JOURNAL OF HAND THERAPY, 2006, 19 (03) : 328 - 349
  • [5] Reliability, validity, and responsiveness of the locomotor capabilities index in adults with lower-limb amputation undergoing prosthetic training
    Franchignoni, F
    Orlandini, D
    Ferriero, G
    Moscato, TA
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2004, 85 (05): : 743 - 748
  • [6] Construct validity, test–retest reliability, and responsiveness of the Arabic version of the upper limb functional index
    Yousef A. Albahrani
    Ali M. Alshami
    BMC Musculoskeletal Disorders, 24
  • [7] Reliability and Validity of the Upper Limb Neurodynamic Test in Symptomatic Neck Patients
    Schallert, Wolfgang
    Ernst, Markus
    MANUELLE THERAPIE, 2013, 17 (01) : 27 - 38
  • [8] Measuring Upper Limb Capacity in Patients After Stroke: Reliability and Validity of the Stroke Upper Limb Capacity Scale
    Houwink, Annemieke
    Roorda, Leo D.
    Smits, Wendy
    Molenaar, Ivo W.
    Geurts, Alexander C.
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2011, 92 (09): : 1418 - 1422
  • [9] Construct validity, test-retest reliability, and responsiveness of the Arabic version of the upper limb functional index
    Albahrani, Yousef A.
    Alshami, Ali M.
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [10] Reliability and validity of the upper limb DASH questionnaire in patients with distal radius fractures
    Westphal, T
    Piatek, S
    Schubert, S
    Schuschke, Y
    Winckler, S
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2002, 140 (04): : 447 - 451