Extending the possibilities of soft x-ray spectrometry through the etching of layered synthetic microstructure monochromators

被引:0
|
作者
Fialin, M
Remy, H
Andre, JM
Chauvineau, JP
Rousseaux, F
Ravet, MF
Decanini, D
Cambril, E
机构
[1] UNIV PARIS 06,LAB CHIM PHYS MAT & RAYONNEMENT,F-75231 PARIS 05,FRANCE
[2] CTR UNIV ORSAY,URA 14,CNRS,INST OPT THEOR & APPL,F-91403 ORSAY,FRANCE
[3] MICROSTRUCT & MICROELECTR LAB,F-92225 BAGNEUX,FRANCE
[4] CAMECA SA,F-92403 COURBEVOIE,FRANCE
关键词
D O I
10.1002/(SICI)1097-4539(199603)25:2<60::AID-XRS138>3.3.CO;2-U
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
One of the major limitations in the use of layered synthetic microstructure (LSM) monochromators for x-ray spectrometry techniques, such as electron probe microanalysis with wavelength-dispersive spectrometers or x-ray fluorescence, is the high-level background generated by the specular signal reflected by these monochromators, The specular reflection increases as the Bragg angle, the glancing angle theta of the incoming radiation with the monochromator surface, decreases, This signal is added to the conventional bremsstrahlung, leading to a strongly curved background whose shape cannot be accurately modelled, Background mis-estimations have drastic consequences for quantification of peaks associated with minor or trace elements. Etching of the LSMs in order to obtain rectangular in-relief gratings (with a period of about 1 mu m) would permitted by a factor of 25-100 the LSMs' intrinsic specular reflection at large glancing angles to be dramatically reduced, as predicted by calculations performed on an Mo-SI LSM designed for the detection of ultra-soft x-rays (<100 eV). These LSM gratings are used in the specular condition, i.e. in the zeroth diffraction order, The nominal reflectivity of the initial LSM is affected by the etching but may be restored by increasing the number of the bilayers deposited, Moreover, the etching improves the spectral resolution of the LSM, thus preventing severe peak interferences which are common in the soft x-ray region. X-ray lithography associated with a reactive ion etching process is shown to be the best compromise to realise large-size (of the order of 1-2 cm(2)), high-resolution gratings etched in thick (ca, 0.5 mu m) LSMs.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 50 条
  • [1] CHARACTERISTICS OF LAYERED SYNTHETIC MICROSTRUCTURE DEVICES FOR X-RAY SPECTROMETRY APPLICATIONS
    BILTOFT, PJ
    [J]. X-RAY SPECTROMETRY, 1993, 22 (04) : 293 - 299
  • [2] Etching of diamonds for x-ray monochromators
    Maj, JA
    Macrander, AT
    Krasnicki, SF
    Fernandez, PB
    Erck, RA
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (03): : 1546 - 1549
  • [3] LAYERED SYNTHETIC MICROSTRUCTURES FOR LONG WAVELENGTH X-RAY SPECTROMETRY
    NICOLOSI, JA
    GROVEN, JP
    MERLO, D
    JENKINS, R
    [J]. OPTICAL ENGINEERING, 1986, 25 (08) : 964 - 969
  • [4] Spectrometers and monochromators for femtosecond soft X-ray sources
    Erko, Alexei
    Braig, Christoph
    Loechel, Heike
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS XIV, 2019, 11108
  • [5] Soft X-ray grating monochromators at the photon factory
    Yagishita, A
    Shigemasa, E
    Yan, Y
    [J]. JOURNAL DE PHYSIQUE IV, 1997, 7 (C2): : 287 - 295
  • [6] Variable groove depth gratings and their applications in soft x-ray monochromators
    Polack, Francois
    Lagarde, Bruno
    Idir, Mourad
    Cloup, Audrey Liard
    Jourdain, Erick
    [J]. SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 639 - +
  • [7] Extending Imaging Volume in Soft X-Ray Tomography
    Ekman, Axel
    Chen, Jian-Hua
    Vanslembrouck, Bieke
    Loconte, Valentina
    Larabell, Carolyn A. A.
    Le Gros, Mark A. A.
    Weinhardt, Venera
    [J]. ADVANCED PHOTONICS RESEARCH, 2023, 4 (04):
  • [8] Heydemann interpolation correction for energy linearization of soft X-ray monochromators.
    Krempasky, J.
    Follath, R.
    Strocov, V. N.
    Schmitt, T.
    Flechsig, U.
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VI, 2011, 8139
  • [9] SCINTILLATION SPECTROMETRY OF SOFT X-RAY RADIATION
    ALPEROVI.VR
    KOMYAK, NI
    LYSKOVICH, AB
    PENTSAK, GM
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1970, (04): : 1219 - +
  • [10] PSEUDOWINDOW FOR USE PRODUCTION IN SOFT OF ULTRAHIGH VACUUM WITH VACUUM ULTRAVIOLET + SOFT X-RAY MONOCHROMATORS
    AXELROD, NN
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (07): : 918 - &