Extending the possibilities of soft x-ray spectrometry through the etching of layered synthetic microstructure monochromators

被引:0
|
作者
Fialin, M
Remy, H
Andre, JM
Chauvineau, JP
Rousseaux, F
Ravet, MF
Decanini, D
Cambril, E
机构
[1] UNIV PARIS 06,LAB CHIM PHYS MAT & RAYONNEMENT,F-75231 PARIS 05,FRANCE
[2] CTR UNIV ORSAY,URA 14,CNRS,INST OPT THEOR & APPL,F-91403 ORSAY,FRANCE
[3] MICROSTRUCT & MICROELECTR LAB,F-92225 BAGNEUX,FRANCE
[4] CAMECA SA,F-92403 COURBEVOIE,FRANCE
关键词
D O I
10.1002/(SICI)1097-4539(199603)25:2<60::AID-XRS138>3.3.CO;2-U
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
One of the major limitations in the use of layered synthetic microstructure (LSM) monochromators for x-ray spectrometry techniques, such as electron probe microanalysis with wavelength-dispersive spectrometers or x-ray fluorescence, is the high-level background generated by the specular signal reflected by these monochromators, The specular reflection increases as the Bragg angle, the glancing angle theta of the incoming radiation with the monochromator surface, decreases, This signal is added to the conventional bremsstrahlung, leading to a strongly curved background whose shape cannot be accurately modelled, Background mis-estimations have drastic consequences for quantification of peaks associated with minor or trace elements. Etching of the LSMs in order to obtain rectangular in-relief gratings (with a period of about 1 mu m) would permitted by a factor of 25-100 the LSMs' intrinsic specular reflection at large glancing angles to be dramatically reduced, as predicted by calculations performed on an Mo-SI LSM designed for the detection of ultra-soft x-rays (<100 eV). These LSM gratings are used in the specular condition, i.e. in the zeroth diffraction order, The nominal reflectivity of the initial LSM is affected by the etching but may be restored by increasing the number of the bilayers deposited, Moreover, the etching improves the spectral resolution of the LSM, thus preventing severe peak interferences which are common in the soft x-ray region. X-ray lithography associated with a reactive ion etching process is shown to be the best compromise to realise large-size (of the order of 1-2 cm(2)), high-resolution gratings etched in thick (ca, 0.5 mu m) LSMs.
引用
收藏
页码:60 / 65
页数:6
相关论文
共 50 条
  • [41] Etching damage and its recovery by soft X-ray irradiation observed in soft X-ray absorption spectra of TiO2 thin film
    Niibe, Masahito
    Sano, Keiji
    Kotaka, Takuya
    Kawakami, Retsuo
    Tominaga, Kikuo
    Nakano, Yoshitaka
    [J]. JOURNAL OF APPLIED PHYSICS, 2013, 113 (12)
  • [42] Investigating the microstructure of soft, microporous matter with synchrotron X-ray tomography
    Metilli, Lorenzo
    Storm, Malte
    Bodey, Andrew J.
    Wanelik, Kaz
    Tyler, Arwen I. I.
    Lazidis, Aris
    Marty-Terrade, Stephanie
    Simone, Elena
    [J]. MATERIALS CHARACTERIZATION, 2021, 180
  • [43] Chemical mapping of polymer microstructure using soft X-ray spectromicroscopy
    Hitchcock, AP
    Stöver, HDH
    Croll, LM
    Childs, RF
    [J]. AUSTRALIAN JOURNAL OF CHEMISTRY, 2005, 58 (06) : 423 - 432
  • [44] Soft X-ray spectromicroscopy and its application to semiconductor microstructure characterization
    Gozzo, F
    Franck, K
    Howells, MR
    Hussain, Z
    Warwick, A
    Padmore, HA
    Triplett, BB
    [J]. ACTA PHYSICA POLONICA A, 1997, 91 (04) : 697 - 705
  • [45] Optimization of an electron cold cathode tube for soft X-ray spectrometry
    Geyer, J
    Reisel, J
    Flock, J
    Broekaert, JAC
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (01) : 49 - 56
  • [46] LAYERED SYNTHETIC MICROSTRUCTURES FOR SOFT-X-RAY SPECTROSCOPY OF MAGNETICALLY CONFINED PLASMAS
    MOOS, W
    ZWICKER, AP
    REGAN, SP
    FINKENTHAL, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2733 - 2737
  • [47] PERFORMANCE OF LAYERED SYNTHETIC MICROSTRUCTURES IN MONOCHROMATOR APPLICATIONS IN THE SOFT-X-RAY REGION
    PIANETTA, P
    BARBEE, TW
    REDAELLI, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3): : 352 - 355
  • [48] Focusing of soft X-ray radiation and characterization of the beam profile enabling X-ray emission spectrometry at nanolayered specimens
    Unterumsberger, R.
    Mueller, M.
    Beckhoff, B.
    Hoenicke, P.
    Pollakowski, B.
    Bjeoumikhova, S.
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 78 : 37 - 41
  • [49] Possibilities and limitations of synchrotron X-ray powder diffraction with double crystal and double multilayer monochromators for microscopic speciation studies
    De Nolf, Wout
    Jaroszewicz, Jakub
    Terzano, Roberto
    Lind, Ole Christian
    Salbu, Brit
    Vekemans, Bart
    Janssens, Koen
    Falkenberg, Gerald
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (08) : 775 - 781
  • [50] Advances in the understanding of multiferroics through soft X-ray diffraction
    Beale, T. A. W.
    Wilkins, S. B.
    Johnson, R. D.
    Prabhakaran, D.
    Boothroyd, A. T.
    Steadman, P.
    Dhesi, S. S.
    Hatton, P. D.
    [J]. EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2012, 208 (01): : 99 - 106