A novel methodology for the optimization of transmission and dosimetric leaf gap parameters

被引:3
|
作者
DiCostanzo, Dominic J. [1 ]
Ayan, Ahmet S. [1 ]
机构
[1] Ohio State Univ, Columbus, OH 43210 USA
来源
关键词
commissioning; dosimetric leaf gap; multileaf collimators; quality assurance; treatment planning systems; IMRT; TOOL;
D O I
10.1002/acm2.13565
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Optimization of dosimetric leaf gap (DLG) and transmission is commonly performed through a manual trial and error process, which can lead to sub-optimal values. The purpose of this work is to create an alternative automated optimization process that provides the optimal DLG and transmission pair for use in a clinical setting. Methods Utilizing the treatment planning system application programming interface, a phase space of clinically viable DLG and transmission pairs was generated. The phase space contained 51,051 dose planes for DLGs between 0.0 and 2.5 mm and transmission values between 0.01% and 2.5%. Thirteen plans were measured for multiple multileaf collimator types and nominal beam energies. The optimization minimized the mean gamma-index and maximized the gamma-index pass rate. The optimized values were validated using five plans excluded from the optimization. Results Of the nominal beam energies and multileaf collimator system (MLC)-type combinations tested, 6/7 showed an increase in gamma-index pass rate and a decrease in mean gamma-index signifying better agreement between measurement and calculation. When comparing the optimized DLG and transmission values to the clinically implemented values identified via an iterative method, 5/7 energy, and MLC type combinations showed no statistically significant changes. In addition, the optimized values were benchmarked against three Task Group 119 plans with published gamma-index pass rates, which had been held out of the optimization. For those plans, the optimized DLG and transmission values provided the same or better gamma-index pass rates. Conclusion We presented a novel and viable automated alternative to current approaches of selecting the DLG and transmission parameters. This method will reduce the time required to determine the clinically acceptable DLG and transmission parameters and ensure optimality for the plans included in the optimization.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Relationship between dosimetric leaf gap and dose calculation errors for high definition multi-leaf collimators in radiotherapy
    Kim, Jinkoo
    Han, James S.
    Hsia, An Ting
    Li, Shidong
    Xu, Zhigang
    Ryu, Samuel
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 5 : 31 - 36
  • [42] Optimization study of adsorption parameters for removal of Cr(VI) using Magnolia leaf biomass by response surface methodology
    Mondal, Naba Kumar
    Samanta, Angela
    Roy, Palas
    Das, Biswajit
    SUSTAINABLE WATER RESOURCES MANAGEMENT, 2019, 5 (04) : 1627 - 1639
  • [43] Optimization study of adsorption parameters for removal of Cr(VI) using Magnolia leaf biomass by response surface methodology
    Naba Kumar Mondal
    Angela Samanta
    Palas Roy
    Biswajit Das
    Sustainable Water Resources Management, 2019, 5 : 1627 - 1639
  • [44] OPTIMIZATION OF THE DESIGN PARAMETERS OF A CHAIN TRANSMISSION
    Ryabov, G. K.
    Seledzhieva, M. A.
    CHEMICAL AND PETROLEUM ENGINEERING, 2013, 49 (7-8) : 476 - 479
  • [45] Optimization of Dosimetric Leaf Gapvalue Using ArcCHECK and Highly Modulated VMAT Plans
    Yu, S.
    Rosenzweig, D.
    Barry, T.
    Pacella, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3220 - 3220
  • [46] Research on Narrow Gap Welding Parameters Optimization
    Lu, Qinghua
    Yu, Zhishui
    Xu, Guoxiang
    He, Jianping
    2009 INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION, VOL III, 2009, : 125 - 128
  • [47] Sensitivity Analysis of Central and Peripheral Dosimetric Leaf Gap for a Double-Stacked Multileaf Collimator
    BaradaranGhahfarokhi, M.
    Yock, A.
    MEDICAL PHYSICS, 2022, 49 (06) : E930 - E930
  • [48] Effects of the dosimetric leaf gap in treatment planning system on the agreement between predicted and measured doses
    Cui, Congwu
    Wu, Xia
    MEDICAL PHYSICS, 2017, 44 (08) : 4389 - 4389
  • [49] On the need for tuning the dosimetric leaf gap for stereotactic treatment plans in the Eclipse treatment planning system
    Vieillevigne, Laure
    Khamphan, Catherine
    Saez, Jordi
    Hernandez, Victor
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (07): : 68 - 77
  • [50] Feasibility of MLC dosimetric leaf gap measurement using OCTAVIUS 4D system
    Geng, H.
    Lam, W. W.
    Bin, Y.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S715 - S716