Glistenings in the AcrySof intraocular lens: Pilot study

被引:77
|
作者
Christiansen, G
Durcan, FJ
Olson, RJ
Christiansen, K
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
[2] Univ Utah, Hlth Sci Ctr, Dept Family & Prevent Med, Salt Lake City, UT USA
来源
关键词
D O I
10.1016/S0886-3350(00)00700-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the prevalence, severity, and visual significance of glistenings seen in the AcrySof (R) intraocular lens (IOL) and determine whether a large in-depth study of this lens is warranted. Setting: John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: Patients who had the AcrySof IOL implanted at 1 institution over the past 4 years were serially selected. Forty-two eyes that had phacoemulsification with implantation of the AcrySof IOL were evaluated. The examination consisted of visual acuity, glare, contrast sensitivity, and dilated fundus and dilated slitlamp evaluations. Glistenings in the IOL were graded at the slitlamp from trace to 4+. Results: All 42 IOLs had some degree of lenticular glistenings. The glistenings were graded as trace in 27 IOLs (64%), 1 + in 5 (12%), 2+ in 5 (12%), 3+ in 3 (7%), and 4+ in 2 (5%). The Snellen acuity in eyes with severe glistenings (greater than or equal to2+) was one-half line lower than in eyes with mild glistenings (+) (P = .01). In all eyes, the Brightness Acuity Tester score was a little more than one-half line lower than the Snellen acuity, and the difference was 1 full line in eyes with glistenings graded above 2+. Fourteen of 15 IOLs (93%) with glistenings graded greater than trace had been in the eye for more than 1 year. There was no evidence that contrast sensitivity was affected by the glistenings. Conclusions Glistenings occurred frequently in AcrySof IOLs, with most cases mild. A larger study of this lens is needed to determine whether severe presentations affect visual function and to understand how glistenings change over time.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [41] Explantation of an acrylic Acrysof® intraocular lens without wound enlargement -: Reply
    Mansour, AM
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (02): : 263 - 263
  • [42] Effect of the AcrySof Natural intraocular lens on blue-yellow perimetry
    Kara-Junior, Newton
    Jardim, Juliana Lopes
    Leme, Eliana de Oliveira
    Dall'Col, Marcelo
    Susanna Junior, Remo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08): : 1328 - 1330
  • [43] Newly observed surface reflex of polyacrylic intraocular lens AcrySof(Alcon).
    Chida, M
    Onishi, T
    Nishihara, H
    Ayaki, M
    Yaguchi, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S8 - S8
  • [44] Anterior capsule opacification spanning the anterior surface of an AcrySof intraocular lens
    Satofuka, S
    Tsunoda, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10): : 2230 - 2231
  • [45] Visual axis opacification after AcrySof intraocular lens implantation in children
    Vasavada, AR
    Trivedi, RH
    Nath, VC
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (05): : 1073 - 1081
  • [46] Posterior capsule opacification in children with "Acrysof" intraocular lens implantation.
    Liu, Y
    Zwaan, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S486 - S486
  • [47] Fellow eye comparison between the ICU accommodative intraocular lens and the Acrysof MA30 monofocal intraocular lens
    Heatley, CJ
    Spalton, DJ
    Hancox, J
    Kumar, A
    Marshall, J
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 140 (02) : 207 - 213
  • [48] Acute haptic-induced pigmentary glaucoma with an AcrySof intraocular lens
    Micheli, T
    Cheung, LM
    Sharma, S
    Assaad, NN
    Guzowski, M
    Francis, IC
    Norman, J
    Coroneo, MT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (10): : 1869 - 1872
  • [49] Monte Carlo simulation of expected outcomes with the AcrySof®toric intraocular lens
    Warren Hill
    Richard Potvin
    BMC Ophthalmology, 8
  • [50] AcrySof acrylic Intraocular lens implantation in children: Clinical indications of biocompatibility
    Wilson, ME
    Elliott, L
    Johnson, B
    Peterseim, MM
    Rah, SH
    Werner, L
    Pandey, SK
    JOURNAL OF AAPOS, 2001, 5 (06): : 377 - 380