Glistenings in the AcrySof intraocular lens: Pilot study

被引:77
|
作者
Christiansen, G
Durcan, FJ
Olson, RJ
Christiansen, K
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
[2] Univ Utah, Hlth Sci Ctr, Dept Family & Prevent Med, Salt Lake City, UT USA
来源
关键词
D O I
10.1016/S0886-3350(00)00700-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the prevalence, severity, and visual significance of glistenings seen in the AcrySof (R) intraocular lens (IOL) and determine whether a large in-depth study of this lens is warranted. Setting: John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: Patients who had the AcrySof IOL implanted at 1 institution over the past 4 years were serially selected. Forty-two eyes that had phacoemulsification with implantation of the AcrySof IOL were evaluated. The examination consisted of visual acuity, glare, contrast sensitivity, and dilated fundus and dilated slitlamp evaluations. Glistenings in the IOL were graded at the slitlamp from trace to 4+. Results: All 42 IOLs had some degree of lenticular glistenings. The glistenings were graded as trace in 27 IOLs (64%), 1 + in 5 (12%), 2+ in 5 (12%), 3+ in 3 (7%), and 4+ in 2 (5%). The Snellen acuity in eyes with severe glistenings (greater than or equal to2+) was one-half line lower than in eyes with mild glistenings (+) (P = .01). In all eyes, the Brightness Acuity Tester score was a little more than one-half line lower than the Snellen acuity, and the difference was 1 full line in eyes with glistenings graded above 2+. Fourteen of 15 IOLs (93%) with glistenings graded greater than trace had been in the eye for more than 1 year. There was no evidence that contrast sensitivity was affected by the glistenings. Conclusions Glistenings occurred frequently in AcrySof IOLs, with most cases mild. A larger study of this lens is needed to determine whether severe presentations affect visual function and to understand how glistenings change over time.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [31] AcrySof toric intraocular lens for post-keratoplasty astigmatism
    Gupta, Nishant
    Ram, Jagat
    Chaudhary, Manish
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (03) : 213 - 215
  • [32] Explantation of an acrylic Acrysof® intraocular lens without wound enlargement
    Mehta, JS
    Wilkins, MR
    Gartry, DS
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2005, 83 (02): : 262 - U3
  • [33] Reversed vaulted AcrySof intraocular lens presenting as pupillary block
    Harsum, S.
    Low, S.
    EYE, 2009, 23 (09) : 1880 - 1882
  • [34] Pupillary block after pupillary capture of an AcrySof intraocular lens
    Nagamoto, S
    Kohzuka, T
    Nagamoto, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (09): : 1271 - 1274
  • [35] Optic capture of the AcrySof intraocular lens in pediatric cataract surgery
    Argento, C
    Badoza, D
    Ugrin, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (10): : 1638 - 1642
  • [36] S-fold implantation technique for the AcrySof intraocular lens
    Evangelista, Jason A.
    Davis, Richard M.
    Stark, Walter J.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02): : 350 - 351
  • [37] Polarized glasses may help in symptomatic cases of intraocular lens glistenings
    Borkenstein, Andreas F.
    Borkenstein, Eva-Maria
    CLINICAL OPTOMETRY, 2019, 11 : 57 - 62
  • [38] Glistenings on Intraocular Lenses
    Beiko, George
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (02) : 89 - 89
  • [39] Drug-induced intraocular lens movement and near visual acuity after AcrySof intraocular lens implantation
    Muftuoglu, O
    Flosal, BM
    Karel, F
    Zilefioglu, G
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (07): : 1298 - 1305
  • [40] Proliferation of lens epithelial cells on the Acrysof intraocular lens: clinical and histological features of a case
    Turner, A
    House, P
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2001, 29 (06): : 426 - 428