Glistenings in the AcrySof intraocular lens: Pilot study

被引:77
|
作者
Christiansen, G
Durcan, FJ
Olson, RJ
Christiansen, K
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Ophthalmol & Visual Sci, Salt Lake City, UT USA
[2] Univ Utah, Hlth Sci Ctr, Dept Family & Prevent Med, Salt Lake City, UT USA
来源
关键词
D O I
10.1016/S0886-3350(00)00700-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the prevalence, severity, and visual significance of glistenings seen in the AcrySof (R) intraocular lens (IOL) and determine whether a large in-depth study of this lens is warranted. Setting: John Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. Methods: Patients who had the AcrySof IOL implanted at 1 institution over the past 4 years were serially selected. Forty-two eyes that had phacoemulsification with implantation of the AcrySof IOL were evaluated. The examination consisted of visual acuity, glare, contrast sensitivity, and dilated fundus and dilated slitlamp evaluations. Glistenings in the IOL were graded at the slitlamp from trace to 4+. Results: All 42 IOLs had some degree of lenticular glistenings. The glistenings were graded as trace in 27 IOLs (64%), 1 + in 5 (12%), 2+ in 5 (12%), 3+ in 3 (7%), and 4+ in 2 (5%). The Snellen acuity in eyes with severe glistenings (greater than or equal to2+) was one-half line lower than in eyes with mild glistenings (+) (P = .01). In all eyes, the Brightness Acuity Tester score was a little more than one-half line lower than the Snellen acuity, and the difference was 1 full line in eyes with glistenings graded above 2+. Fourteen of 15 IOLs (93%) with glistenings graded greater than trace had been in the eye for more than 1 year. There was no evidence that contrast sensitivity was affected by the glistenings. Conclusions Glistenings occurred frequently in AcrySof IOLs, with most cases mild. A larger study of this lens is needed to determine whether severe presentations affect visual function and to understand how glistenings change over time.
引用
收藏
页码:728 / 733
页数:6
相关论文
共 50 条
  • [21] AcrySof IQ PanOptix Intraocular Lens Versus Extended Depth of Focus Intraocular Lens and Trifocal Intraocular Lens: A Clinical Overview
    Sudhir, Rachapalle Reddi
    Dey, Arindam
    Bhattacharrya, Shovan
    Bahulayan, Amit
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (04): : 335 - 349
  • [22] Visual complaints associated with the AcrySof acrylic intraocular lens
    Farbowitz, MA
    Zabriskie, NA
    Crandall, AS
    Olson, RJ
    Miller, KM
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09): : 1339 - 1345
  • [23] Influence of glistenings on the optical quality of acrylic foldable intraocular lens
    Oshika, T
    Shiokawa, Y
    Amano, S
    Mitomo, K
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (09) : 1034 - 1037
  • [24] ALCON ACRYSOF IOL GLISTENINGS: IS THE CHROMOPHORE THE CULPRIT?
    House, Philip
    Abdul-Rahman, Anmar
    Richards, Josephine
    D'Souza, Blasco
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2018, 46 : 52 - 52
  • [25] Clinical evaluation of glistenings in AcrySof™ intraocular lenses packaged in the wagon wheel packing system in 111 eyes
    Kusano, Y
    Sakuma, A
    Ohkoshi, K
    Yasuda, A
    Orihara, Y
    Yamaguchi, T
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S297 - S297
  • [26] GLISTENINGS IN INTRAOCULAR LENSES
    Richards, Jo
    House, Philip
    Kaminski, Tessa
    Nguyen, Peter
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 44 : 48 - 48
  • [27] Reversed vaulted AcrySof intraocular lens presenting as pupillary block
    S Harsum
    S Low
    Eye, 2009, 23 : 1880 - 1882
  • [28] Stereoacuity After Refractive Lens Exchange With AcrySof ReSTOR Intraocular Lens Implantation
    Ferrer-Blasco, Teresa
    Montes-Mico, Robert
    Cervino, Alejandro
    Alfonso, Jose F.
    Gonzalez-Meijome, Jose M.
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (11) : 1000 - 1004
  • [29] COST EFFECTIVENESS ANALYSIS OF THE ACRYSOF CACHET PHAKIC INTRAOCULAR LENS
    Fisher, M.
    Waycaster, C.
    Vanoli, A.
    Muston, D.
    VALUE IN HEALTH, 2010, 13 (03) : A146 - A146
  • [30] Astigmatism management in cataract surgery with the AcrySof toric intraocular lens
    Bauer, Noel J. C.
    de Vries, Niels E.
    Webers, Carroll A. B.
    Hendrikse, Fred
    Nuijts, Rudy M. M. A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (09): : 1483 - 1488