RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period

被引:8
|
作者
Nienkemper, Manuel [1 ]
Willmann, Jan H. [1 ]
Becker, Kathrin [1 ]
Drescher, Dieter [1 ]
机构
[1] Heinrich Heine Univ Dusseldorf, Dept Orthodont, Moorenstr 5,Bldg 18-21, D-40225 Dusseldorf, Germany
关键词
Mini-implants; Stability; Long term; Implant length; RESONANCE FREQUENCY-ANALYSIS; STABILITY; BONE; ANCHORAGE; PALATE;
D O I
10.1186/s40510-020-0305-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background In dental implantology, the development of stability over time is a well-investigated topic. In case of orthodontic mini-implants, quantitative data for long-term stability is not available yet. This study aims to clinically investigate the long-term stability of mini-implants inserted in the midsagittal suture of the anterior palate. Moreover, the influence of the length of implants was elucidated. The stability of 2 x 9 and 2 x 11 mm mini-implants after orthodontic treatment (9 mm, 2.84 years +/- 1.25 years; 11 mm, 3.17 years +/- 0.96 years) was assessed by resonance frequency analysis (RFA). The obtained long-term pieces of data were compared with each other (9 mm vs 11 mm), as well as with the data from the matched early stability groups, to assess the initial and early secondary stability after the insertion from previous clinical trials. Results For both lengths, the long-term stability (2 x 9 mm, 25.12 +/- 7.11, n = 21; 2 x 11 mm, 24.39 +/- 5.82, n = 18) was significantly lower than primary stability (2 x 9 mm, 36.14 +/- 6.08, n = 19; 2 x 11 mm, 33.35 +/- 3.53, n = 20). The differences within the groups disappeared over the initial healing period: after 4 weeks for the 2 x 9 mm implants and after 2 weeks for the 2 x 11 mm implants. Also, the 2 x 9 mm and 2 x 11 mm implants showed comparable long-term stability values. Conclusion The stability of midpalatal mini-implants does not change in the long term after the initial healing period. Moreover, 2 x 9 mm mini-implants seem to be appropriate for orthodontic anchorage, as the stability of 2 x 11 mm implants is not higher. Therefore, owing to lower invasiveness, 2 x 9 mm implants should be preferred.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] The most distal palatal ruga for placement of orthodontic mini-implants
    Hourfar, Jan
    Ludwig, Bjorn
    Bister, Dirk
    Braun, Anna
    Kanavakis, Georgios
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (04) : 373 - 378
  • [42] Insertion Angle Impact on Primary Stability of Orthodontic Mini-implants
    Wilmes, Benedict
    Su, Yu-Yu
    Drescher, Dieter
    ANGLE ORTHODONTIST, 2008, 78 (06) : 1065 - 1070
  • [43] In vitro evaluation of insertion and removal torques of orthodontic mini-implants
    Pithon, M. M.
    Nojima, M. G.
    Nojima, L. I.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (01) : 80 - 85
  • [44] Effect of rotation bump on removal torque of orthodontic mini-implants
    Gansukh, Odontuya
    Jeong, Jong-Wha
    Kim, Jong-Wan
    Kim, Young-Kyun
    Lee, Jong-Ho
    Kim, Tae-Woo
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2013, 39 (06) : 269 - 273
  • [45] Mechanical and Histological Effects of Resorbable Blasting Media Surface Treatment on the Initial Stability of Orthodontic Mini-Implants
    Gansukh, Odontuya
    Jeong, Jong-Wha
    Kim, Jong-Wan
    Lee, Jong-Ho
    Kim, Tae-Woo
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [46] Comparative Study of Mini-implants versus Standard Implants in Orthodontic Anchorage for Space Closure
    Sahoo, Sanjay Kumar
    Chekka, Manjunath
    Chawla, Riddhi
    Naimatullah, Mohammed Nehal
    Misra, K. Kumar
    Kandikatla, Pradeep
    Prashant, M. C.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S2458 - S2460
  • [47] Analysis of time to failure of orthodontic mini-implants after insertion or loading
    Jeong, Jong-Wha
    Kim, Jong-Wan
    Lee, Nam-Ki
    Kim, Young-Kyun
    Lee, Jong-Ho
    Kim, Tae-Woo
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2015, 41 (05) : 240 - 245
  • [48] An in vitro study of factors affecting the primary stability of orthodontic mini-implants
    Holm, Lindsy
    Cunningham, Susan J.
    Petrie, Aviva
    Cousley, Richard R. J.
    ANGLE ORTHODONTIST, 2012, 82 (06) : 1022 - 1028
  • [49] Effects of the diameter and shape of orthodontic mini-implants on microdamage to the cortical bone
    Lee, Nam-Ki
    Baek, Seung-Hak
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 138 (01) : 8 - 9
  • [50] Factors affecting the long-term stability of orthodontic mini-implants
    Motoyoshi, Mitsuru
    Uemura, Miwa
    Ono, Akiko
    Okazaki, Kumiko
    Shigeeda, Toru
    Shimizu, Noriyoshi
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (05) : 588.e1 - 588.e5