Effect of rotation bump on removal torque of orthodontic mini-implants

被引:1
|
作者
Gansukh, Odontuya [1 ]
Jeong, Jong-Wha [1 ]
Kim, Jong-Wan [2 ]
Kim, Young-Kyun [2 ,3 ]
Lee, Jong-Ho [4 ,5 ]
Kim, Tae-Woo [1 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Orthodont, Sect Dent, 82 Gumi Ro 173 Beon Gil, Seoul 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Oral & Maxillofacial Surg, Sect Dent, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[5] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
关键词
Mini-implant; Rotation bump; Torque; Torque ratio; Angular momentum;
D O I
10.5125/jkaoms.2013.39.6.269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirtytwo mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [1] Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants
    Yun, Soon-dong
    Lim, Sung-hoon
    KOREAN JOURNAL OF ORTHODONTICS, 2009, 39 (02) : 95 - 104
  • [2] Convenient removal of orthodontic mini-implants
    Kim, Hyewon
    Kim, Tae Kyung
    Lee, Shin-Jae
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 131 (04) : S90 - S91
  • [4] Design of orthodontic mini-implants contributing to implantation torque
    Katic, V.
    Spalj, S.
    Opalic, M.
    Domitran, Z.
    BIODENTAL ENGINEERING II, 2014, : 29 - 33
  • [5] Investigation of bacteremia induced by removal of orthodontic mini-implants
    Livas, Christos
    Delli, Konstantina
    Karapsias, Stergios
    Pandis, Nikolaos
    Ren, Yijin
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (01) : 16 - 21
  • [6] Insertion torque and success of orthodontic mini-implants: A systematic review
    Reynders, Reint A. Meursinge
    Ronchi, Laura
    Ladu, Luisa
    van Etten-Jamaludin, Faridi
    Bipat, Shandra
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (05) : 596 - +
  • [7] Removal torque of osseointegrated mini-implants:: an in vivo evaluation
    Favero, Luca Giuseppe
    Pisoni, Andrea
    Paganelli, Corrado
    EUROPEAN JOURNAL OF ORTHODONTICS, 2007, 29 (05) : 443 - 448
  • [8] Applications of orthodontic mini-implants
    J. Seehra
    British Dental Journal, 2008, 204 (3) : 160 - 160
  • [9] Applications of Orthodontic Mini-Implants
    Spencer, Meryl
    JOURNAL OF ORTHODONTICS, 2008, 35 (02) : 136 - 136
  • [10] Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants
    Motoyoshi, Mitsuru
    Yoshida, Tohru
    Ono, Akiko
    Shimizu, Noriyoshi
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (05) : 779 - 784