Effect of rotation bump on removal torque of orthodontic mini-implants

被引:1
|
作者
Gansukh, Odontuya [1 ]
Jeong, Jong-Wha [1 ]
Kim, Jong-Wan [2 ]
Kim, Young-Kyun [2 ,3 ]
Lee, Jong-Ho [4 ,5 ]
Kim, Tae-Woo [1 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Orthodont, Sect Dent, 82 Gumi Ro 173 Beon Gil, Seoul 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Oral & Maxillofacial Surg, Sect Dent, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[5] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
关键词
Mini-implant; Rotation bump; Torque; Torque ratio; Angular momentum;
D O I
10.5125/jkaoms.2013.39.6.269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirtytwo mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [21] A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs
    Okazaki, J.
    Komasa, Y.
    Sakai, D.
    Kamada, A.
    Ikeo, T.
    Toda, I.
    Suwa, F.
    Inoue, M.
    Etoh, T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (07) : 647 - 650
  • [22] Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study
    Romanec, Cristian Liviu
    Panaite, Tinela
    Zetu, Irina Nicoleta
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [23] Mechanical strength of orthodontic infrazygomatic mini-implants
    Wang, Chau-Hsiang
    Wu, Ju-Hui
    Lee, Kun-Tsung
    Hsu, Kun-Rong
    Wang, Huang Chi
    Chen, Chun-Ming
    ODONTOLOGY, 2011, 99 (01) : 98 - 100
  • [24] Effects of acid etching and calcium chloride immersion on removal torque and bone-cutting ability of orthodontic mini-implants
    Jang, Tae-Ho
    Park, Jae-Hyun
    Moon, Won
    Chae, Jong-Moon
    Chang, Na-Young
    Kang, Kyung-Hwa
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2018, 154 (01) : 108 - 114
  • [25] Mechanical strength of orthodontic infrazygomatic mini-implants
    Chau-Hsiang Wang
    Ju-Hui Wu
    Kun-Tsung Lee
    Kun-Rong Hsu
    Huang Chi Wang
    Chun-Ming Chen
    Odontology, 2011, 99 : 98 - 100
  • [26] Morphological and structural characteristics of orthodontic mini-implants
    AlSamak, Saeed
    Bitsanis, Elias
    Makou, Margarita
    Eliades, George
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2012, 73 (01): : 58 - 71
  • [27] Removal torque values of surface-treated mini-implants after loading
    Kim, Seong-Hun
    Cho, Jae-Hee
    Chung, Kyu-Rhim
    Kook, Yoon-Ah
    Nelson, Gerald
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (01) : 36 - 43
  • [28] Effect of metal ions released from orthodontic mini-implants on osteoclastogenesis
    Charoenpong, Hataichanok
    Ritprajak, Patcharee
    DENTAL AND MEDICAL PROBLEMS, 2021, 58 (03) : 327 - 333
  • [29] Influence of Manual Screwdriver Design in Combination With and Without Predrilling on Insertion Torque of Orthodontic Mini-Implants
    Katalinic, Andrej
    Zrinski, Magda Trinajstic
    Vrancic, Zlatka Roksandic
    Spalj, Stjepan
    IMPLANT DENTISTRY, 2017, 26 (01) : 95 - 100
  • [30] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128