Effect of rotation bump on removal torque of orthodontic mini-implants

被引:1
|
作者
Gansukh, Odontuya [1 ]
Jeong, Jong-Wha [1 ]
Kim, Jong-Wan [2 ]
Kim, Young-Kyun [2 ,3 ]
Lee, Jong-Ho [4 ,5 ]
Kim, Tae-Woo [1 ]
机构
[1] Seoul Natl Univ, Sch Dent, Dept Orthodont, Seoul, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Orthodont, Sect Dent, 82 Gumi Ro 173 Beon Gil, Seoul 463707, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Oral & Maxillofacial Surg, Sect Dent, Seoul, South Korea
[4] Seoul Natl Univ, Sch Dent, Dept Oral & Maxillofacial Surg, Seoul, South Korea
[5] Seoul Natl Univ, Sch Dent, Dent Res Inst, Seoul, South Korea
关键词
Mini-implant; Rotation bump; Torque; Torque ratio; Angular momentum;
D O I
10.5125/jkaoms.2013.39.6.269
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study is designed to evaluate the mechanical stability of orthodontic mini-implants with vertical grooves in rabbits. Materials and Methods: This study was done from March 2011 to February 2012 in Dental Research Institute of Seoul National University. Thirtytwo mini-implants in the control group and 32 in the rotation bump (RB) group were inserted in the tibias of 16 rabbits and were removed after two weeks and four weeks, respectively. The maximum insertion torque (MIT), maximum removal torque (MRT), torque ratio (TR) of MRT to MIT and removal angular momentum (RAM) were all measured at the time of removal. Results: There were no significant differences between the two groups in MIT and MRT at two weeks or four weeks. However, TR and RAM at four weeks in the RB group were significantly higher than in the control group (P<0.05). TR of the RB group was significantly increased at four weeks (P<0.05). In both groups, RAM at four weeks was significantly higher than at two weeks (P<0.05). Conclusion: These results suggest that RB of the mini-implant could provide resistance to the removal rotation, although it did not increase the MRT.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [41] Effects of wobbling angle on the stability measures of orthodontic mini-implants during insertion and removal procedures
    Cho, Il-Sik
    Baek, Sang-Ho
    Kim, Young Ho
    ANGLE ORTHODONTIST, 2013, 83 (06) : 1009 - 1014
  • [42] Impact of implant design on primary stability of orthodontic mini-implants
    Wilmes, Benedict
    Ottenstreuer, Stephanie
    Su, Yu-Yu
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 42 - 50
  • [43] Critical factors for the success of orthodontic mini-implants: A systematic review
    Chen, Yan
    Kyung, Hee Moon
    Zhao, Wen Ting
    Yu, Won Jae
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (03) : 284 - 291
  • [44] Orthodontic mini-implants: clinical and peri-implant evaluation
    Vicioni-Marques, Fernanda
    Brandariz Pimentel, Diego Jesus
    Nakane Matsumoto, Mirian Aiko
    Sasso Stuani, Maria Bernadete
    Romano, Fabio Lourenco
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2022, 11 (01) : 22 - 28
  • [45] Use of Orthodontic Mini-Implants for Maxillomandibular Fixation in Mandibular Fracture
    Medeiros Pires, Mario Sergio
    Reinhardt, Leandro Calcagno
    Antonello, Guilherme de Marco
    do Couto, Ricardo Torres
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2011, 4 (04) : 213 - 216
  • [46] The validation of Periotest values for the evaluation of orthodontic mini-implants' stability
    Cha, Jung-Yul
    Yu, Hyung-Seog
    Hwang, Chung-Ju
    KOREAN JOURNAL OF ORTHODONTICS, 2010, 40 (03) : 167 - 175
  • [47] Patient Expectations, Acceptance and Preferences in Treatment with Orthodontic Mini-implants
    Lehnen, Sandra
    McDonald, Fraser
    Bourauel, Christoph
    Baxmann, Martin
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2011, 72 (02): : 93 - 102
  • [48] Comparative analysis of numerical and experimental data of orthodontic mini-implants
    Chatzigianni, Athina
    Keilig, Ludger
    Duschner, Heinz
    Goetz, Hermann
    Eliades, Theodore
    Bourauel, Christoph
    EUROPEAN JOURNAL OF ORTHODONTICS, 2011, 33 (05) : 468 - 475
  • [49] DO THE UNTREATED SURFACES OF ORTHODONTIC MINI-IMPLANTS HAVE OSSEOINTEGRATION?
    Jiman , Paula
    Baciut, Mihaela
    Bran, Simion
    Muntean, Alexandrina
    Porumb, Ioana
    Pop, Andreea Simona
    Dinu, Cristian
    Barbu-Tudoran, Lucian
    Baciut, Grigore
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2024, 16 (02): : 726 - 738
  • [50] Surface Analysis of Orthodontic Mini-Implants after Their Clinical Use
    Ioana, Tamara Rahela
    Boeru, Filip George
    Antoniac, Iulian
    Mitrut, Ioana
    Staicu, Ionela Elisabeta
    Rauten, Anne Marie
    Uriciuc, Willi Andrei
    Manolea, Horia Octavian
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (09)