Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants

被引:3
|
作者
Motoyoshi, Mitsuru [1 ]
Yoshida, Tohru [1 ]
Ono, Akiko [1 ]
Shimizu, Noriyoshi [1 ]
机构
[1] Nihon Univ, Sch Dent, Dept Orthodont, Chiyoda Ku, Tokyo 1018310, Japan
关键词
mini-implants; orthodontic; risk factor; survival; temporary anchorage devices;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To examine the relationship between cortical bone thickness, inter-root distance (horizontal space), distance from alveolar crest to the bottom of maxillary sinus (vertical space) at the prepared site, and implant placement torque and the success rate of mini-implants placed for orthodontic anchorage. Materials and Methods: After computerized tomography examination, mini-implants 1.6 mm wide and 8 mm long were placed in the posterior alveolar bone. The mini-implant was judged a success when orthodontic force could be applied for at least 6 months without pain or clinically detectable mobility. The unpaired t test was performed to examine differences between the success and failure groups. The chi-square analysis or Fisher exact probability test was used to compare the implant success according to placement torque, location, and patient gender. P values less than .05 were considered significant. Results: The subjects included 4 males (11 implants) and 28 females (76 implants) who ranged in age from 14.6 to 42.8 years. The success rate of the 87 implants was 87.4%. Cortical bone thickness was significantly greater in the success group (1.42 +/- 0.59 mm vs 0.97 +/- 0.31 mm, P =.015). The success rate was significantly higher in the group with an implant placement torque of 8 to 10 Ncm (100%) as compared to implants with higher or lower placement torques. The odds ratio for failure of the mini-implant was 6.93 (P =.047) when the cortical bone thickness was less than 1.0 mm relative to 1.0 mm or more. Conclusion: A relationship between stability after implant placement and the width and height of the peri-implant bone was not demonstrated. The prepared site should have a cortical bone thickness of at least 1.0 mm, and the placement torque should be controlled up to 10 Ncm.
引用
收藏
页码:779 / 784
页数:6
相关论文
共 50 条
  • [1] The effect of cortical bone thickness on the stability of orthodontic mini-implants and on the stress distribution in surrounding bone
    Motoyoshi, M.
    Inaba, M.
    Ono, A.
    Ueno, S.
    Shimizu, N.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 38 (01) : 13 - 18
  • [2] Effects of cortical bone thickness and trabecular bone density on primary stability of orthodontic mini-implants
    Pan, Chin-Yun
    Liu, Pao-Hsin
    Tseng, Yu-Chuan
    Chou, Szu-Ting
    Wu, Chao-Yi
    Chang, Hong-Po
    JOURNAL OF DENTAL SCIENCES, 2019, 14 (04) : 383 - 388
  • [3] Cortical bone thickness in the buccal posterior region for orthodontic mini-implants
    Ono, A.
    Motoyoshi, M.
    Shimizu, N.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (04) : 334 - 340
  • [4] Impact of Implant Design and Bone Properties on the Primary Stability of Orthodontic Mini-Implants
    Redzepagic-Vrazalica, Lejla
    Mesic, Elmedin
    Pervan, Nedim
    Hadziabdic, Vahidin
    Delic, Muamer
    Glusac, Mirza
    APPLIED SCIENCES-BASEL, 2021, 11 (03): : 1 - 10
  • [5] A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femurs
    Okazaki, J.
    Komasa, Y.
    Sakai, D.
    Kamada, A.
    Ikeo, T.
    Toda, I.
    Suwa, F.
    Inoue, M.
    Etoh, T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (07) : 647 - 650
  • [6] Impact of implant design on primary stability of orthodontic mini-implants
    Wilmes, Benedict
    Ottenstreuer, Stephanie
    Su, Yu-Yu
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 42 - 50
  • [7] Influence of cortical thickness on the stability of mini-implants with microthreads
    Lemes Vilani, Giselle Naback
    de Oliveira Ruellas, Antonio Carlos
    Mattos, Claudia Trindade
    Fernandes, Daniel Jogaib
    Elias, Carlos Nelson
    BRAZILIAN ORAL RESEARCH, 2015, 29 (01): : 1 - 7
  • [8] Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion angles
    Meira, Thiago Martins
    Tanaka, Orlando Motohiro
    Ronsani, Maiara Medeiros
    Maruo, Ivan Toshio
    Guariza-Filho, Odilon
    Camargo, Elisa Souza
    Maruo, Hiroshi
    EUROPEAN JOURNAL OF ORTHODONTICS, 2013, 35 (06) : 766 - 771
  • [9] Effect of rotation bump on removal torque of orthodontic mini-implants
    Gansukh, Odontuya
    Jeong, Jong-Wha
    Kim, Jong-Wan
    Kim, Young-Kyun
    Lee, Jong-Ho
    Kim, Tae-Woo
    JOURNAL OF THE KOREAN ASSOCIATION OF ORAL AND MAXILLOFACIAL SURGEONS, 2013, 39 (06) : 269 - 273
  • [10] Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study
    Hung, Bui Quang
    Yu, Wonjae
    Park, Hyo-Sang
    Kyung, Hee-Moon
    Hong, Mihee
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (02) : 248 - 254