Effect of cortical bone thickness and implant placement torque on stability of orthodontic mini-implants

被引:3
|
作者
Motoyoshi, Mitsuru [1 ]
Yoshida, Tohru [1 ]
Ono, Akiko [1 ]
Shimizu, Noriyoshi [1 ]
机构
[1] Nihon Univ, Sch Dent, Dept Orthodont, Chiyoda Ku, Tokyo 1018310, Japan
关键词
mini-implants; orthodontic; risk factor; survival; temporary anchorage devices;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To examine the relationship between cortical bone thickness, inter-root distance (horizontal space), distance from alveolar crest to the bottom of maxillary sinus (vertical space) at the prepared site, and implant placement torque and the success rate of mini-implants placed for orthodontic anchorage. Materials and Methods: After computerized tomography examination, mini-implants 1.6 mm wide and 8 mm long were placed in the posterior alveolar bone. The mini-implant was judged a success when orthodontic force could be applied for at least 6 months without pain or clinically detectable mobility. The unpaired t test was performed to examine differences between the success and failure groups. The chi-square analysis or Fisher exact probability test was used to compare the implant success according to placement torque, location, and patient gender. P values less than .05 were considered significant. Results: The subjects included 4 males (11 implants) and 28 females (76 implants) who ranged in age from 14.6 to 42.8 years. The success rate of the 87 implants was 87.4%. Cortical bone thickness was significantly greater in the success group (1.42 +/- 0.59 mm vs 0.97 +/- 0.31 mm, P =.015). The success rate was significantly higher in the group with an implant placement torque of 8 to 10 Ncm (100%) as compared to implants with higher or lower placement torques. The odds ratio for failure of the mini-implant was 6.93 (P =.047) when the cortical bone thickness was less than 1.0 mm relative to 1.0 mm or more. Conclusion: A relationship between stability after implant placement and the width and height of the peri-implant bone was not demonstrated. The prepared site should have a cortical bone thickness of at least 1.0 mm, and the placement torque should be controlled up to 10 Ncm.
引用
收藏
页码:779 / 784
页数:6
相关论文
共 50 条
  • [21] Alveolar bone density and its clinical implication in the placement of dental implants and orthodontic mini-implants
    Almasoud, Naif N.
    Tanneru, Nagaraju
    Marei, Hesham F.
    SAUDI MEDICAL JOURNAL, 2016, 37 (06) : 684 - 689
  • [22] Dimensions Define Stability: Insertion Torque of Orthodontic Mini-Implants: A Comparative In Vitro Study
    Romanec, Cristian Liviu
    Panaite, Tinela
    Zetu, Irina Nicoleta
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (05)
  • [23] Insertion torque and success of orthodontic mini-implants: A systematic review
    Reynders, Reint A. Meursinge
    Ronchi, Laura
    Ladu, Luisa
    van Etten-Jamaludin, Faridi
    Bipat, Shandra
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (05) : 596 - +
  • [24] Buccal cortical bone thickness for mini-implant placement
    Baumgaertel, Sebastian
    Hans, Mark G.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) : 230 - 235
  • [25] Orthodontic mini-implants: clinical and peri-implant evaluation
    Vicioni-Marques, Fernanda
    Brandariz Pimentel, Diego Jesus
    Nakane Matsumoto, Mirian Aiko
    Sasso Stuani, Maria Bernadete
    Romano, Fabio Lourenco
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2022, 11 (01) : 22 - 28
  • [26] Revisiting the stability of mini-implants used for orthodontic anchorage
    Yao, Chung-Chen Jane
    Chang, Hao-Hueng
    Chang, Jenny Zwei-Chieng
    Lai, Hsiang-Hua
    Lu, Shao-Chun
    Chen, Yi-Jane
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (11) : 1122 - 1128
  • [27] The most distal palatal ruga for placement of orthodontic mini-implants
    Hourfar, Jan
    Ludwig, Bjorn
    Bister, Dirk
    Braun, Anna
    Kanavakis, Georgios
    EUROPEAN JOURNAL OF ORTHODONTICS, 2015, 37 (04) : 373 - 378
  • [28] Applications of orthodontic mini-implants
    J. Seehra
    British Dental Journal, 2008, 204 (3) : 160 - 160
  • [29] Applications of Orthodontic Mini-Implants
    Spencer, Meryl
    JOURNAL OF ORTHODONTICS, 2008, 35 (02) : 136 - 136
  • [30] Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants
    Yun, Soon-dong
    Lim, Sung-hoon
    KOREAN JOURNAL OF ORTHODONTICS, 2009, 39 (02) : 95 - 104