RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period

被引:8
|
作者
Nienkemper, Manuel [1 ]
Willmann, Jan H. [1 ]
Becker, Kathrin [1 ]
Drescher, Dieter [1 ]
机构
[1] Heinrich Heine Univ Dusseldorf, Dept Orthodont, Moorenstr 5,Bldg 18-21, D-40225 Dusseldorf, Germany
关键词
Mini-implants; Stability; Long term; Implant length; RESONANCE FREQUENCY-ANALYSIS; STABILITY; BONE; ANCHORAGE; PALATE;
D O I
10.1186/s40510-020-0305-x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background In dental implantology, the development of stability over time is a well-investigated topic. In case of orthodontic mini-implants, quantitative data for long-term stability is not available yet. This study aims to clinically investigate the long-term stability of mini-implants inserted in the midsagittal suture of the anterior palate. Moreover, the influence of the length of implants was elucidated. The stability of 2 x 9 and 2 x 11 mm mini-implants after orthodontic treatment (9 mm, 2.84 years +/- 1.25 years; 11 mm, 3.17 years +/- 0.96 years) was assessed by resonance frequency analysis (RFA). The obtained long-term pieces of data were compared with each other (9 mm vs 11 mm), as well as with the data from the matched early stability groups, to assess the initial and early secondary stability after the insertion from previous clinical trials. Results For both lengths, the long-term stability (2 x 9 mm, 25.12 +/- 7.11, n = 21; 2 x 11 mm, 24.39 +/- 5.82, n = 18) was significantly lower than primary stability (2 x 9 mm, 36.14 +/- 6.08, n = 19; 2 x 11 mm, 33.35 +/- 3.53, n = 20). The differences within the groups disappeared over the initial healing period: after 4 weeks for the 2 x 9 mm implants and after 2 weeks for the 2 x 11 mm implants. Also, the 2 x 9 mm and 2 x 11 mm implants showed comparable long-term stability values. Conclusion The stability of midpalatal mini-implants does not change in the long term after the initial healing period. Moreover, 2 x 9 mm mini-implants seem to be appropriate for orthodontic anchorage, as the stability of 2 x 11 mm implants is not higher. Therefore, owing to lower invasiveness, 2 x 9 mm implants should be preferred.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Predrilling of the implant site: Is it necessary for orthodontic mini-implants?
    Baumgaertel, Sebastian
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (06) : 825 - 829
  • [22] Investigation of bacteremia induced by removal of orthodontic mini-implants
    Livas, Christos
    Delli, Konstantina
    Karapsias, Stergios
    Pandis, Nikolaos
    Ren, Yijin
    EUROPEAN JOURNAL OF ORTHODONTICS, 2014, 36 (01) : 16 - 21
  • [23] Mechanical Evaluation of Orthodontic Mini-Implants of Different Lengths
    Pithon, Matheus Melo
    Fonseca Figueiredo, Daniel Santos
    Oliveira, Dauro Douglas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) : 479 - 486
  • [24] Long-term durability of orthodontic mini-implants
    Abbassy, Mona Aly
    Bakry, Ahmed Samir
    Zawawi, Khalid Hashim
    Hassan, Ali Habib
    ODONTOLOGY, 2018, 106 (02) : 208 - 214
  • [25] Microflora associated with successful and failed orthodontic mini-implants
    Apel, Stephanie
    Apel, Christian
    Morea, Camillo
    Tortamano, Andre
    Dominguez, Gladys Cristina
    Conrads, Georg
    CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (11) : 1186 - 1190
  • [26] Impact of implant design on primary stability of orthodontic mini-implants
    Wilmes, Benedict
    Ottenstreuer, Stephanie
    Su, Yu-Yu
    Drescher, Dieter
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2008, 69 (01): : 42 - 50
  • [27] Orthodontic mini-implants: clinical and peri-implant evaluation
    Vicioni-Marques, Fernanda
    Brandariz Pimentel, Diego Jesus
    Nakane Matsumoto, Mirian Aiko
    Sasso Stuani, Maria Bernadete
    Romano, Fabio Lourenco
    JOURNAL OF THE WORLD FEDERATION OF ORTHODONTISTS, 2022, 11 (01) : 22 - 28
  • [28] Critical factors for the success of orthodontic mini-implants: A systematic review
    Chen, Yan
    Kyung, Hee Moon
    Zhao, Wen Ting
    Yu, Won Jae
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (03) : 284 - 291
  • [29] Use of Orthodontic Mini-Implants for Maxillomandibular Fixation in Mandibular Fracture
    Medeiros Pires, Mario Sergio
    Reinhardt, Leandro Calcagno
    Antonello, Guilherme de Marco
    do Couto, Ricardo Torres
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2011, 4 (04) : 213 - 216
  • [30] The validation of Periotest values for the evaluation of orthodontic mini-implants' stability
    Cha, Jung-Yul
    Yu, Hyung-Seog
    Hwang, Chung-Ju
    KOREAN JOURNAL OF ORTHODONTICS, 2010, 40 (03) : 167 - 175