Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions

被引:62
|
作者
Haiter-Neto, F. [1 ]
Wenzel, A. [2 ]
Gotfredsen, E. [2 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Dentomaxillofacial Radiol Area, BR-13414901 Piracicaba, SP, Brazil
[2] Univ Aarhus, Dept Oral Dent, Sch Dent, DK-8000 Aarhus C, Denmark
关键词
radiography; digital; computed tomography; diagnosis; dental caries;
D O I
10.1259/dmfr/87103878
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to compare the caries diagnostic accuracy of two cone beam CT systems (CBCT) with two intraoral receptors, one digital and one film. Methods: 100 non-cavitated extracted human teeth were placed with approximal contacts: each row of teeth comprised I canine, I first and second premolar., and I first and second molar. Radiographs of each tooth were recorded using two intraoral modalities: Digora-fmx (Soredex) and film (Kodak Insight), and two CBCT systems: NewTom 3G (Quantitative Radiology) in three fields of view (FOVs): pixel size of 0.36 mm (FOV 12 inches), pixel size of 0.25 mm (FOV 9 inches), pixel size of 0.16 mm (FOV 6 inches); and 3DX Accuitomo (Morita), pixel size of 0.125 (FOV 4 cm). The volumetric data from the CBCT systems were reconstructed and sectioned (0.5 mm) in the mesiodistal tooth plane. Six observers scored approximal and occlusal surfaces for the detection of caries lesions. The teeth were clinically sectioned and microscopy served as the validation tool. Two-way ANOVA tested differences in sensitivity, specificity and overall true score (true positives plus true negatives) between the modalities. Results: Microscopy of approximal surfaces found 63% sound, 3101 enamel and 6% dentin lesions; of occlusal surfaces, 6% sound, 59% enamel, 19% dentin lesions and 16% had fillings. For approximal surfaces, NewTom 12 inch and 9 inch images had significantly lower sensitivities than Accuitomo (P < 0.02); and NewTom 9 inch and 6 inch had significantly lower specificities than film and Digora-fmx (P < 0.04). Accuitomo images were not significantly different from film or Digora-fmx images for any of the tested variables (P > 0.2). For occlusal surfaces, the Accuitomo presented a higher sensitivity than the other systems. Specificity and overall true score did not differ (P > 0.06) among the modalities. Conclusions: In conclusion, the NewTom 3G CBCT had a lower diagnostic accuracy for detection of caries lesions than intraoral modalities and the 3DX Accuitomo CBCT. The Accuitomo CBCT had a higher sensitivity than the intraoral systems for detection of lesions in dentin, but the overall true score was not higher.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [1] A comparative study of the diagnostic accuracy of cone beam computed tomography and intraoral radiographic modalities for the detection of noncavitated caries
    J. Krzyżostaniak
    T. Kulczyk
    B. Czarnecka
    A. Surdacka
    Clinical Oral Investigations, 2015, 19 : 667 - 672
  • [2] A comparative study of the diagnostic accuracy of cone beam computed tomography and intraoral radiographic modalities for the detection of noncavitated caries
    Krzyzostaniak, J.
    Kulczyk, T.
    Czarnecka, B.
    Surdacka, A.
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (03) : 667 - 672
  • [3] Diagnostic Accuracy of Cone Beam Computed Tomography Compared with Intraoral Radiography for the Detection of Noncavitated Occlusal Carious Lesions
    Krzyzostaniak, Joanna
    Surdacka, Anna
    Kulczyk, Tomasz
    Dyszkiewicz-Konwinska, Marta
    Owecka, Magdalena
    CARIES RESEARCH, 2014, 48 (05) : 461 - 466
  • [4] Detection accuracy of in vitro approximal caries by cone beam computed tomography images
    Qu, Xingmin
    Li, Gang
    Zhang, Zuyan
    Ma, Xuchen
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E24 - E27
  • [5] Combining Intraoral Scans, Cone Beam Computed Tomography and Face Scans: The Virtual Patient
    Mangano, Carlo
    Luongo, Fabrizia
    Migliario, Mario
    Mortellaro, Carmen
    Mangano, Francesco Guido
    JOURNAL OF CRANIOFACIAL SURGERY, 2018, 29 (08) : 2241 - 2246
  • [6] Effect of artifact area on cone beam computed tomography scans when integrated with intraoral scans
    Biao, Yan
    Kim, Dong-Wook
    Hwang, Hyeon-Shik
    Lee, Kyung-Min
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2021, 131 (04): : 468 - 474
  • [7] A Comparative Study of the Diagnostic Accuracy of Cone Beam Computed Tomography and Phosphor Storage Plate for Detection of Noncavitated Occlusal Caries
    Ramezani, Leila
    Salemi, Fatemeh
    Shokri, Abbas
    Sichani, Hamed Fallahi
    Mirzayi, Maryam
    Bagheri, Mohammad
    DENTAL AND MEDICAL PROBLEMS, 2016, 53 (02) : 186 - 192
  • [8] Comparison of cone beam computed tomography and digital intraoral radiography performance in the detection of artificially induced recurrent caries-like lesions
    Sousa Melo, Saulo Leonardo
    Furtado Belem, Manuella Dias
    Prieto, Lucia Trazzi
    Machado Tabchoury, Cinthia Pereira
    Haiter-Neto, Francisco
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 124 (03): : 306 - 314
  • [9] Cone-beam Computed Tomography Compared with Intraoral Radiographic Lesions in Endodontic Outcome Studies: A Systematic Review
    Aminoshariae, Anita
    Kulild, James C.
    Syed, Ali
    JOURNAL OF ENDODONTICS, 2018, 44 (11) : 1626 - 1631
  • [10] Effect of Amalgam Restorations and Operation Parameters on Diagnostic Accuracy of Caries Detection Using Cone Beam Computed Tomography: An In Vitro Study
    Mehanny, Mohamed
    AlMohareb, Rahaf A.
    Noujeim, Marcel
    SCANNING, 2021, 2021