A comparative study of the diagnostic accuracy of cone beam computed tomography and intraoral radiographic modalities for the detection of noncavitated caries

被引:0
|
作者
J. Krzyżostaniak
T. Kulczyk
B. Czarnecka
A. Surdacka
机构
[1] Poznan University of Medical Sciences,Department of Conservative Dentistry and Periodontology
[2] Poznan University of Medical Sciences,Department of Biomaterials and Experimental Dentistry with Section of Dental Radiology
来源
关键词
Cone beam computed tomography; Radiography; Dental caries;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:667 / 672
页数:5
相关论文
共 50 条
  • [1] A comparative study of the diagnostic accuracy of cone beam computed tomography and intraoral radiographic modalities for the detection of noncavitated caries
    Krzyzostaniak, J.
    Kulczyk, T.
    Czarnecka, B.
    Surdacka, A.
    CLINICAL ORAL INVESTIGATIONS, 2015, 19 (03) : 667 - 672
  • [2] A Comparative Study of the Diagnostic Accuracy of Cone Beam Computed Tomography and Phosphor Storage Plate for Detection of Noncavitated Occlusal Caries
    Ramezani, Leila
    Salemi, Fatemeh
    Shokri, Abbas
    Sichani, Hamed Fallahi
    Mirzayi, Maryam
    Bagheri, Mohammad
    DENTAL AND MEDICAL PROBLEMS, 2016, 53 (02) : 186 - 192
  • [3] Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions
    Haiter-Neto, F.
    Wenzel, A.
    Gotfredsen, E.
    DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (01) : 18 - 22
  • [4] Diagnostic Accuracy of Cone Beam Computed Tomography Compared with Intraoral Radiography for the Detection of Noncavitated Occlusal Carious Lesions
    Krzyzostaniak, Joanna
    Surdacka, Anna
    Kulczyk, Tomasz
    Dyszkiewicz-Konwinska, Marta
    Owecka, Magdalena
    CARIES RESEARCH, 2014, 48 (05) : 461 - 466
  • [5] Detection accuracy of in vitro approximal caries by cone beam computed tomography images
    Qu, Xingmin
    Li, Gang
    Zhang, Zuyan
    Ma, Xuchen
    EUROPEAN JOURNAL OF RADIOLOGY, 2011, 79 (02) : E24 - E27
  • [6] Diagnostic accuracy of conventional orthodontic radiographic modalities and cone-beam computed tomography for localization of impacted maxillary canine teeth
    Salari, Behzad
    Tofangchiha, Maryam
    Padisar, Parviz
    Reda, Rodolfo
    Zanza, Alessio
    Testarelli, Luca
    SCIENCE PROGRESS, 2024, 107 (01)
  • [7] Effect of Amalgam Restorations and Operation Parameters on Diagnostic Accuracy of Caries Detection Using Cone Beam Computed Tomography: An In Vitro Study
    Mehanny, Mohamed
    AlMohareb, Rahaf A.
    Noujeim, Marcel
    SCANNING, 2021, 2021
  • [8] Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption
    Durack, C.
    Patel, S.
    Davies, J.
    Wilson, R.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) : 136 - 147
  • [9] Accuracy of cone beam computed tomography-derived casts: A comparative study
    Shujaat, Sohaib
    Shaheen, Eman
    Novillo, Felipe
    Politis, Constantinus
    Jacobs, Reinhilde
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (01): : 95 - 102
  • [10] Comparison of periodontal evaluation by cone-beam computed tomography, and clinical and intraoral radiographic examinations
    Zhang, Wenjian
    Rajani, Shazia
    Wang, Bing-Yan
    ORAL RADIOLOGY, 2018, 34 (03) : 208 - 218