Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions

被引:62
|
作者
Haiter-Neto, F. [1 ]
Wenzel, A. [2 ]
Gotfredsen, E. [2 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Dentomaxillofacial Radiol Area, BR-13414901 Piracicaba, SP, Brazil
[2] Univ Aarhus, Dept Oral Dent, Sch Dent, DK-8000 Aarhus C, Denmark
关键词
radiography; digital; computed tomography; diagnosis; dental caries;
D O I
10.1259/dmfr/87103878
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to compare the caries diagnostic accuracy of two cone beam CT systems (CBCT) with two intraoral receptors, one digital and one film. Methods: 100 non-cavitated extracted human teeth were placed with approximal contacts: each row of teeth comprised I canine, I first and second premolar., and I first and second molar. Radiographs of each tooth were recorded using two intraoral modalities: Digora-fmx (Soredex) and film (Kodak Insight), and two CBCT systems: NewTom 3G (Quantitative Radiology) in three fields of view (FOVs): pixel size of 0.36 mm (FOV 12 inches), pixel size of 0.25 mm (FOV 9 inches), pixel size of 0.16 mm (FOV 6 inches); and 3DX Accuitomo (Morita), pixel size of 0.125 (FOV 4 cm). The volumetric data from the CBCT systems were reconstructed and sectioned (0.5 mm) in the mesiodistal tooth plane. Six observers scored approximal and occlusal surfaces for the detection of caries lesions. The teeth were clinically sectioned and microscopy served as the validation tool. Two-way ANOVA tested differences in sensitivity, specificity and overall true score (true positives plus true negatives) between the modalities. Results: Microscopy of approximal surfaces found 63% sound, 3101 enamel and 6% dentin lesions; of occlusal surfaces, 6% sound, 59% enamel, 19% dentin lesions and 16% had fillings. For approximal surfaces, NewTom 12 inch and 9 inch images had significantly lower sensitivities than Accuitomo (P < 0.02); and NewTom 9 inch and 6 inch had significantly lower specificities than film and Digora-fmx (P < 0.04). Accuitomo images were not significantly different from film or Digora-fmx images for any of the tested variables (P > 0.2). For occlusal surfaces, the Accuitomo presented a higher sensitivity than the other systems. Specificity and overall true score did not differ (P > 0.06) among the modalities. Conclusions: In conclusion, the NewTom 3G CBCT had a lower diagnostic accuracy for detection of caries lesions than intraoral modalities and the 3DX Accuitomo CBCT. The Accuitomo CBCT had a higher sensitivity than the intraoral systems for detection of lesions in dentin, but the overall true score was not higher.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [11] Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorption
    Durack, C.
    Patel, S.
    Davies, J.
    Wilson, R.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (02) : 136 - 147
  • [12] Diagnostic accuracy of limited-volume cone-beam computed tomography in the detection of periapical bone loss: 360° scans versus 180° scans
    Lennon, S.
    Patel, S.
    Foschi, F.
    Wilson, R.
    Davies, J.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2011, 44 (12) : 1118 - 1127
  • [13] Accuracy of reconstructed images from cone-beam computed tomography scans
    Lamichane, Manish
    Anderson, Nina Kay
    Rigali, Paul H.
    Seldin, Edward B.
    Will, Leslie A.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (02) : 156.e1 - 156.e6
  • [14] Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations
    Shokri, Abbas
    Eskandarloo, Amir
    Norouzi, Marouf
    Poorolajal, Jalal
    Majidi, Gelareh
    Aliyaly, Alireza
    IMAGING SCIENCE IN DENTISTRY, 2018, 48 (01) : 11 - 19
  • [15] The detection and management of root resorption lesions using intraoral radiography and cone beam computed tomography - an in vivo investigation
    Patel, S.
    Dawood, A.
    Wilson, R.
    Horner, K.
    Mannocci, F.
    INTERNATIONAL ENDODONTIC JOURNAL, 2009, 42 (09) : 831 - 838
  • [16] Accuracy of cone-beam computed tomography for syndesmosis injury diagnosis compared to conventional computed tomography
    Hamard, Marion
    Neroladaki, Angeliki
    Bagetakos, Ilias
    Dubois-Ferriere, Victor
    Montet, Xavier
    Boudabbous, Sana
    FOOT AND ANKLE SURGERY, 2020, 26 (04) : 265 - 272
  • [17] Evaluation of diagnostic accuracy of cone beam computed tomography and multi-detector computed tomography for detection of anatomical variations in rhinoplasty
    Rouientan, Abdolreza
    Khodaparast, Mohammad Bashir
    Safi, Yaser
    HEAD & FACE MEDICINE, 2024, 20 (01)
  • [18] Evaluation of diagnostic accuracy of cone beam computed tomography and multi-detector computed tomography for detection of anatomical variations in rhinoplasty
    Abdolreza Rouientan
    Mohammad Bashir Khodaparast
    Yaser Safi
    Head & Face Medicine, 20
  • [19] Accuracy of linear measurements made on cone beam computed tomography scans at different magnifications
    Ghaznavi, Aisan
    Ghaznavi, Dara
    Valizadeh, Solmaz
    Vasegh, Zahra
    Al-Shuhayeb, Muna
    JOURNAL OF CONTEMPORARY MEDICAL SCIENCES, 2019, 5 (05): : 274 - 278
  • [20] The Virtual Patient in Daily Orthodontics: Matching Intraoral and Facial Scans without Cone Beam Computed Tomography
    Campobasso, Alessandra
    Battista, Giovanni
    Lo Muzio, Eleonora
    Lo Muzio, Lorenzo
    APPLIED SCIENCES-BASEL, 2022, 12 (19):