Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions

被引:62
|
作者
Haiter-Neto, F. [1 ]
Wenzel, A. [2 ]
Gotfredsen, E. [2 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, Dentomaxillofacial Radiol Area, BR-13414901 Piracicaba, SP, Brazil
[2] Univ Aarhus, Dept Oral Dent, Sch Dent, DK-8000 Aarhus C, Denmark
关键词
radiography; digital; computed tomography; diagnosis; dental caries;
D O I
10.1259/dmfr/87103878
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim was to compare the caries diagnostic accuracy of two cone beam CT systems (CBCT) with two intraoral receptors, one digital and one film. Methods: 100 non-cavitated extracted human teeth were placed with approximal contacts: each row of teeth comprised I canine, I first and second premolar., and I first and second molar. Radiographs of each tooth were recorded using two intraoral modalities: Digora-fmx (Soredex) and film (Kodak Insight), and two CBCT systems: NewTom 3G (Quantitative Radiology) in three fields of view (FOVs): pixel size of 0.36 mm (FOV 12 inches), pixel size of 0.25 mm (FOV 9 inches), pixel size of 0.16 mm (FOV 6 inches); and 3DX Accuitomo (Morita), pixel size of 0.125 (FOV 4 cm). The volumetric data from the CBCT systems were reconstructed and sectioned (0.5 mm) in the mesiodistal tooth plane. Six observers scored approximal and occlusal surfaces for the detection of caries lesions. The teeth were clinically sectioned and microscopy served as the validation tool. Two-way ANOVA tested differences in sensitivity, specificity and overall true score (true positives plus true negatives) between the modalities. Results: Microscopy of approximal surfaces found 63% sound, 3101 enamel and 6% dentin lesions; of occlusal surfaces, 6% sound, 59% enamel, 19% dentin lesions and 16% had fillings. For approximal surfaces, NewTom 12 inch and 9 inch images had significantly lower sensitivities than Accuitomo (P < 0.02); and NewTom 9 inch and 6 inch had significantly lower specificities than film and Digora-fmx (P < 0.04). Accuitomo images were not significantly different from film or Digora-fmx images for any of the tested variables (P > 0.2). For occlusal surfaces, the Accuitomo presented a higher sensitivity than the other systems. Specificity and overall true score did not differ (P > 0.06) among the modalities. Conclusions: In conclusion, the NewTom 3G CBCT had a lower diagnostic accuracy for detection of caries lesions than intraoral modalities and the 3DX Accuitomo CBCT. The Accuitomo CBCT had a higher sensitivity than the intraoral systems for detection of lesions in dentin, but the overall true score was not higher.
引用
收藏
页码:18 / 22
页数:5
相关论文
共 50 条
  • [21] Comparison of photothermal radiometry and modulated luminescence, intraoral radiography, and cone beam computed tomography for detection of natural caries under restorations
    Dayo, Adeyinka F.
    Amaechi, Bennett T.
    Noujeim, Marcel
    Deahl, S. Thomas
    Gakunga, Peter
    Katkar, Rujuta
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2020, 129 (05): : 539 - 548
  • [22] Evaluation of the accuracy of cone-beam computed tomography for measuring intraoral soft tissue thickness
    Wang, Xue-Yu
    Shi, Yan-Wei
    Zhou, Song
    Chen, Yu-Hui
    Yan, Shu
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2022, 15 (01): : 37 - 44
  • [23] In vitro assessment of cone beam local computed tomography for proximal caries detection
    Kalathingal, Sajitha M.
    Mol, Andre
    Tyndall, Donald A.
    Caplan, Daniel J.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2007, 104 (05): : 699 - 704
  • [24] Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries
    Charuakkra, Arnon
    Prapayasatok, Sangsom
    Janhom, Apirum
    Pongsiriwet, Surawut
    Verochana, Karune
    Mahasantipiya, Phattaranant
    IMAGING SCIENCE IN DENTISTRY, 2011, 41 (04) : 143 - 150
  • [25] Diagnostic Accuracy of Cone Beam Computed Tomography for Dimensional Linear Measurements in the Mandible
    Halperin-Sternfeld, Michal
    Machtei, Eli E.
    Horwitz, Jacob
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 593 - 599
  • [26] Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
    Jakob Neubauer
    Matthias Benndorf
    Claudia Ehritt-Braun
    Kilian Reising
    Tayfun Yilmaz
    Christopher Klein
    Horst Zajonc
    Elmar Kotter
    Mathias Langer
    Sebastian Moritz Goerke
    Scientific Reports, 8
  • [27] Comparison of the diagnostic accuracy of cone beam computed tomography and radiography for scaphoid fractures
    Neubauer, Jakob
    Benndorf, Matthias
    Ehritt-Braun, Claudia
    Reising, Kilian
    Yilmaz, Tayfun
    Klein, Christopher
    Zajonc, Horst
    Kotter, Elmar
    Langer, Mathias
    Goerke, Sebastian Moritz
    SCIENTIFIC REPORTS, 2018, 8
  • [28] Diagnostic Accuracy of Cone-Beam Computed Tomography in the Evaluation of Chronic Rhinosinusitis
    Zojaji, Ramin
    Naghibzadeh, Masoud
    Baf, Morteza Mazloum Farsi
    Nekooei, Sirous
    Bataghva, Behrokh
    Noorbakhsh, Sara
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY HEAD AND NECK SURGERY, 2015, 77 (01): : 55 - 60
  • [29] Diagnostic accuracy of conventional orthodontic radiographic modalities and cone-beam computed tomography for localization of impacted maxillary canine teeth
    Salari, Behzad
    Tofangchiha, Maryam
    Padisar, Parviz
    Reda, Rodolfo
    Zanza, Alessio
    Testarelli, Luca
    SCIENCE PROGRESS, 2024, 107 (01)
  • [30] A study on the image registration accuracy of intrafraction cone beam computed tomography images
    Arumugam, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S566 - S566