New approach for attenuation correction in SPECT images, using linear optimization

被引:0
|
作者
Kamyad, A. Vahidian [2 ]
Eskandari, M. H. Noori [2 ]
Midani, M. Naji [1 ]
Saffar, M. Hajizadeh [1 ]
机构
[1] Mashad Univ Med Sci, Dept Med Phys, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Dept Math, Mashhad, Iran
来源
关键词
Piece wise linearization; linear optimization; SPECT image; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements This can be corrected via different physical or mathematical approaches As the correction equation in mathematical approaches is nonlinear in this study a new method of linearization called Piece Wise Linearization (PWL) is introduced and to substantiate its validity for SPECT image reconstructions a phantom study is performed Material and Methods A SPECT scan of a homemade heart phantom filled with 2 mCi Tc-99m was acquired by dual head Siemens E Cam gamma camera equipped with LEHR collimator Row data of the scan were transferred in DICOM format to a pc computer for reconstruction of the images using MLEM iterative algorithm in Matlab software Result Attenuation map of the phantom mu(x) were derived using PWL with linear optimization approach Based on that the attenuation corrected SPECT image of the phantom were reconstructed and compared with non corrected image using MLEM iterative algorithm Comparison of the corrected and non corrected images confirmed with CT attenuation correction method Conclusion Attenuation correction in SPECT image can be achieved successfully using emission data and piecewise linearization with linear optimization approach The corrected image of f(x) and attenuation map mu(x) of the heart phantom using this approach promise acceptable image quality for diagnostic clinical use Iran J Radiat Res 2010, 8 (2) 111 116
引用
收藏
页码:111 / 116
页数:6
相关论文
共 50 条
  • [21] Influence of a Headrest on Reconstruction and Attenuation Correction of Human Brain SPECT Images
    Ohba, Makoto
    Kokubo, Yasuaki
    Suzuki, Koji
    Kanoto, Masafumi
    Sonoda, Yukihiko
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2021, 49 (01) : 54 - 57
  • [22] Impact of CT attenuation correction by SPECT/CT in brain perfusion images
    Kazunari Ishii
    Kohei Hanaoka
    Masahiro Okada
    Seishi Kumano
    Yoshihiro Komeya
    Norio Tsuchiya
    Makoto Hosono
    Takamichi Murakami
    Annals of Nuclear Medicine, 2012, 26 : 241 - 247
  • [23] Noise in ML-EM reconstruction of SPECT images with attenuation correction
    Liew, SC
    Ng, YK
    Hasegawa, BH
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1198 - 1202
  • [24] Implementation and performance evaluation of artificial intelligence based SPECT attenuation correction on clinical SPECT images
    Szolikova, M.
    Kovacs, A.
    Husztik, B.
    Meszaros, N.
    Nagy, F.
    Garai, I.
    Barna, S.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (SUPPL 1) : S162 - S163
  • [25] Attenuation correction in cardiac spect using consistency conditions
    da Silva, Ana Maria Marques
    Robilotta, Cecil Chow
    2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 271 - +
  • [26] Attenuation correction using SPECT emission data only
    Gourion, Daniel
    Noll, Dominikus
    Gantet, Pierre
    Celler, Anna
    Esquerré, Jean-Paul
    IEEE Transactions on Nuclear Science, 2002, 49 I (05) : 2172 - 2179
  • [27] Validation of attenuation correction using SPECT/CT in MPI
    Ali, L.
    Panchadar, S.
    Al-Sayed, Y.
    Biswas, G.
    Al-Garashi, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S493 - S493
  • [28] Attenuation correction using SPECT emission data only
    Gourion, D
    Noll, D
    Gantet, P
    Celler, A
    Esquerré, JP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) : 2172 - 2179
  • [29] Attenuation correction using SPECT emission data only
    Gourion, D
    Noll, D
    Gantet, P
    Celler, A
    Esquerré, JP
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1522 - 1526
  • [30] Attenuation correction in SPECT without attenuation map
    Kacperski, Krzysztof
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3820 - 3822