New approach for attenuation correction in SPECT images, using linear optimization

被引:0
|
作者
Kamyad, A. Vahidian [2 ]
Eskandari, M. H. Noori [2 ]
Midani, M. Naji [1 ]
Saffar, M. Hajizadeh [1 ]
机构
[1] Mashad Univ Med Sci, Dept Med Phys, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Dept Math, Mashhad, Iran
来源
关键词
Piece wise linearization; linear optimization; SPECT image; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements This can be corrected via different physical or mathematical approaches As the correction equation in mathematical approaches is nonlinear in this study a new method of linearization called Piece Wise Linearization (PWL) is introduced and to substantiate its validity for SPECT image reconstructions a phantom study is performed Material and Methods A SPECT scan of a homemade heart phantom filled with 2 mCi Tc-99m was acquired by dual head Siemens E Cam gamma camera equipped with LEHR collimator Row data of the scan were transferred in DICOM format to a pc computer for reconstruction of the images using MLEM iterative algorithm in Matlab software Result Attenuation map of the phantom mu(x) were derived using PWL with linear optimization approach Based on that the attenuation corrected SPECT image of the phantom were reconstructed and compared with non corrected image using MLEM iterative algorithm Comparison of the corrected and non corrected images confirmed with CT attenuation correction method Conclusion Attenuation correction in SPECT image can be achieved successfully using emission data and piecewise linearization with linear optimization approach The corrected image of f(x) and attenuation map mu(x) of the heart phantom using this approach promise acceptable image quality for diagnostic clinical use Iran J Radiat Res 2010, 8 (2) 111 116
引用
收藏
页码:111 / 116
页数:6
相关论文
共 50 条
  • [41] A method for attenuation and scatter correction of brain SPECT based on computed tomography images
    Larsson, A
    Johansson, L
    Sundström, T
    Åhlström, KR
    NUCLEAR MEDICINE COMMUNICATIONS, 2003, 24 (04) : 411 - 420
  • [42] Clinical impact of CT attenuation correction by SPECT/CT in brain perfusion images
    Ishii, Kazunari
    Hanaoka, Kohei
    Okada, Masahiro
    Kumano, Seishi
    Komeya, Yoshihiro
    Tsuchiya, Norio
    Hosono, Makoto
    Murakami, Takamichi
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [43] Optimization of the Attenuation Coefficient for Chang Attenuation Correction in 123I Brain Perfusion SPECT
    Murata, Taisuke
    Hayashi, Yuri
    Onoguchi, Masahisa
    Shibutani, Takayuki
    Iimori, Takashi
    Sawada, Koichi
    Umezawa, Tetsuro
    Masuda, Yoshitada
    Uno, Takashi
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2023, 51 (01) : 49 - 56
  • [44] Accurate attenuation correction in SPECT imaging using optimization of bilinear functions and assuming an unknown spatially-varying attenuation distribution
    Ramlau, R
    Clackdoyle, R
    Noo, F
    Bal, G
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 2000, 80 (09): : 613 - 621
  • [45] Attenuation correction for bone SPECT using patient body outlines
    Case, JA
    Licho, R
    Weaver, JP
    King, MA
    JOURNAL OF NUCLEAR MEDICINE, 1996, 37 (05) : 499 - 499
  • [46] ATTEMPT FOR ATTENUATION AND SCATTERING CORRECTION OF SPECT USING TRANSMISSION CT
    MUKAI, T
    ISHII, Y
    TAMAKI, N
    MINATO, K
    YAMAMOTO, K
    MAEDA, H
    ITOH, H
    FUJITA, T
    TORIZUKA, K
    JOURNAL OF NUCLEAR MEDICINE, 1982, 23 (05) : P85 - P85
  • [47] Attenuation correction in cardiac SPECT using computer simulation.
    Shirakawa, S
    Maeda, H
    Koga, S
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 304P - 304P
  • [48] Novel attenuation correction of SPECT images using scatter photopeak window data for the detection of coronary artery disease
    Yamauchi, Yohei
    Kanzaki, Yumiko
    Otsuka, Kaoru
    Hayashi, Masuo
    Okada, Mami
    Nogi, Shimpei
    Morita, Hideaki
    Komori, Tsuyoshi
    Ishizaka, Nobukazu
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (01) : 109 - 117
  • [49] Novel attenuation correction of SPECT images using scatter photopeak window data for the detection of coronary artery disease
    Yohei Yamauchi
    Yumiko Kanzaki
    Kaoru Otsuka
    Masuo Hayashi
    Mami Okada
    Shimpei Nogi
    Hideaki Morita
    Tsuyoshi Komori
    Nobukazu Ishizaka
    Journal of Nuclear Cardiology, 2014, 21 : 109 - 117
  • [50] CT-attenuation correction in myocardial perfusion SPECT using a hybrid SPECT/CT
    Namdar, M
    Siegrist, PT
    Koepfli, P
    Tschuetscher, P
    Hany, TF
    Kaufmann, PA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S261 - S261