In this work the approach for obtaining the attenuation maps for cardiac SPECT was the estimation directly from the emission data, without transmission imaging, based on consistency conditions of the attenuated Radon transform. Several counting rates and attenuation coefficients on the corrected images were studied, using the MCAT phantom and SimSET package. Given an initial estimate of the attenuation map, the use of consistency conditions always resulted in a same form, for any values initials of the group of parameters. In spite of the fact that the error falls with the increasing counting rate, higher counts are not able to determine the best attenuation coefficient. The results shows that consistency conditions can be useful for attenuation correction, but the scattering correction is the most important factor in the quantitative reconstruction in cardiac SPECT.
引用
收藏
页码:271 / +
页数:2
相关论文
共 50 条
  • [1] Attenuation correction in SPECT using consistency conditions for the exponential ray transform
    Mennessier, C
    Noo, F
    Clackdoyle, R
    Bal, G
    Desbat, L
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10): : 2483 - 2510
  • [2] Data consistency conditions for attenuation map alignment in pinhole cardiac SPECT
    Wells, R. Glenn
    Clackdoyle, Rolf
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [3] Feasibility of attenuation map alignment in pinhole cardiac SPECT using exponential data consistency conditions
    Wells, R. Glenn
    Clackdoyle, Rolf
    MEDICAL PHYSICS, 2021, 48 (09) : 4955 - 4965
  • [4] Attenuation correction in cardiac SPECT using computer simulation.
    Shirakawa, S
    Maeda, H
    Koga, S
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 304P - 304P
  • [5] CORRECTION OF NONUNIFORM ATTENUATION IN CARDIAC SPECT IMAGING
    TSUI, BMW
    GULLBERG, GT
    EDGERTON, ER
    BALLARD, JG
    PERRY, JR
    MCCARTNEY, WH
    BERG, J
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (04) : 497 - 507
  • [6] Evaluation of Attenuation Correction Process in Cardiac SPECT Images
    Naji, Maryam
    Zakavi, Seyed Rasoul
    Hajizadeh, Mohsen
    Momennezhad, Mehdi
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2008, 16 (02): : 1 - 7
  • [7] ATTENUATION CORRECTION IN CARDIAC SPECT WITHOUT A TRANSMISSION MEASUREMENT
    WALLIS, JW
    MILLER, TR
    KOPPEL, P
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (03) : 506 - 512
  • [8] Direct Attenuation Correction Using Deep Learning for Cardiac SPECT: A Feasibility Study
    Yang, Jaewon
    Shi, Luyao
    Wang, Rui
    Miller, Edward J.
    Sinusas, Albert J.
    Liu, Chi
    Gullberg, Grant T.
    Seo, Youngho
    JOURNAL OF NUCLEAR MEDICINE, 2021, 62 (11) : 1645 - 1652
  • [9] ATTENUATION CORRECTION IN CARDIAC SPECT WITHOUT A TRANSMISSION SOURCE
    WALLIS, JW
    MILLER, TR
    KOPPEL, PL
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P82 - P82
  • [10] Attenuation correction in PET using consistency conditions and a three-dimensional template
    Bromiley, A
    Welch, A
    Chilcott, F
    Waikar, S
    McCallum, S
    Dodd, M
    Craib, S
    Schweiger, L
    Sharp, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (04) : 1371 - 1377