Attenuation correction in cardiac spect using consistency conditions

被引:0
|
作者
da Silva, Ana Maria Marques [1 ]
Robilotta, Cecil Chow [2 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Inst Phys, Porto Alegre, RS, Brazil
[2] Univ Sao Paulo, Inst Phys, Sao Paulo, Brazil
关键词
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
In this work the approach for obtaining the attenuation maps for cardiac SPECT was the estimation directly from the emission data, without transmission imaging, based on consistency conditions of the attenuated Radon transform. Several counting rates and attenuation coefficients on the corrected images were studied, using the MCAT phantom and SimSET package. Given an initial estimate of the attenuation map, the use of consistency conditions always resulted in a same form, for any values initials of the group of parameters. In spite of the fact that the error falls with the increasing counting rate, higher counts are not able to determine the best attenuation coefficient. The results shows that consistency conditions can be useful for attenuation correction, but the scattering correction is the most important factor in the quantitative reconstruction in cardiac SPECT.
引用
收藏
页码:271 / +
页数:2
相关论文
共 50 条
  • [11] Impact of attenuation correction, scatter correction and resolution recovery an cardiac SPECT
    Keng, F
    Chang, SM
    Salfity, M
    Verant, MS
    CIRCULATION, 1999, 100 (18) : 312 - 312
  • [12] Attenuation correction in PET using consistency information
    Welch, A.
    Campbell, C.
    Clackdoyle, R.
    Natterer, F.
    Hudson, M.
    Bromiley, A.
    Mikecz, P.
    Chillcot, F.
    Dodd, M.
    Hopwood, P.
    Craib, S.
    Gullberg, G.T.
    Sharp, P.
    IEEE Transactions on Nuclear Science, 1998, 45 (6 pt 2): : 3134 - 3141
  • [13] Attenuation correction in PET using consistency information
    Welch, A
    Campbell, C
    Clackdoyle, R
    Natterer, F
    Hudson, M
    Bromiley, A
    Mikecz, P
    Chillcot, F
    Dodd, M
    Hopwood, P
    Craib, S
    Gullberg, GT
    Sharp, P
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (06) : 3134 - 3141
  • [14] Attenuation correction in SPECT using active surfaces
    Ecole de Technologie Superieure, Montreal, Canada
    IEEE Nucl Sci Symp Med Imaging Conf, (1995-1999):
  • [15] Attenuation correction for cardiac SPECT imaging using small field-of-view detectors
    Bai, Chuanyong
    Conwell, Richard
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2112 - 2116
  • [16] Attenuation correction in cardiac SPECT: The boy who cried wolf?
    Germano, Guido
    Slomka, Piotr J.
    Berman, Daniel S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (01) : 25 - 35
  • [17] SCATTER IMAGING WITH EXTERNAL SOURCE FOR ATTENUATION CORRECTION OF CARDIAC SPECT
    CHANG, W
    HUANG, G
    ALDOOHAN, S
    PAWLOWSKI, J
    LONCARIC, S
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P195 - P195
  • [18] Attenuation correction in cardiac spect: the boy who cried wolf?
    Guido Germano
    Piotr J. Slomka
    Daniel S. Bermana
    Journal of Nuclear Cardiology, 2007, 14 : 25 - 35
  • [19] ATTENUATION CORRECTION OF THALLIUM SPECT USING DIFFERENTIAL ATTENUATION OF THALLIUM PHOTONS
    HANSEN, CL
    SIEGEL, JA
    VANDECKER, WA
    JOURNAL OF NUCLEAR MEDICINE, 1989, 30 (10) : 1746 - 1746
  • [20] ATTENUATION CORRECTION OF THALLIUM SPECT USING DIFFERENTIAL ATTENUATION OF THALLIUM PHOTONS
    HANSEN, CL
    SIEGEL, JA
    JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (08) : 1574 - 1577