Feasibility of attenuation map alignment in pinhole cardiac SPECT using exponential data consistency conditions

被引:0
|
作者
Wells, R. Glenn [1 ]
Clackdoyle, Rolf [2 ]
机构
[1] Univ Ottawa, Div Cardiol, Heart Inst, Ottawa, ON, Canada
[2] Univ Grenoble Alpes, TIMC, Grenoble INP, CNRS,INP, Grenoble, France
关键词
attenuation; data consistency conditions; pinhole; SPECT; TOMOGRAPHY; RECONSTRUCTION; VALIDATION; SYSTEM;
D O I
10.1002/mp.15058
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Dedicated cardiac SPECT systems do not typically include an integrated CT scanner and thus attenuation correction requires registration of separately acquired transmission scans. Data consistency conditions are equations that express the redundancy between projections while taking into account the attenuation effects. This study assessed the feasibility of applying exponential data consistency conditions to rebinned pinhole projections for attenuation-map registration in pinhole cardiac SPECT. Methods Simulations of an anthropomorphic computer phantom with three different tracer activity distributions were performed with and without clinical levels of noise in the projection data. The first activity distribution contained activity only within the myocardium which satisfied the assumptions of the data consistency conditions. The other two distributions violated these assumptions by adding background activity and uptake in the liver. Simulations included acquisitions with 360, 31, and 9 pinhole projections and detector pixel sizes of 0.75 and 2.5 mm. A metric based on the average difference between pairs of exponential projections was used to evaluate registration accuracy. Results When activity is restricted to the myocardium, the registration error was 3.0 mm for 31 noisy pinhole projections with a detector size of 2.5 mm. When activity is added to the background and the liver, a correction for the extra-cardiac activity is needed but when applied, a registration error of 6.0 mm was achieved. Conclusion These results suggest that it may be feasible to use exponential data consistency conditions to register pinhole cardiac SPECT and CT transmission data. Taxonomy: 8-6 (IM-SPECT/Registration).
引用
收藏
页码:4955 / 4965
页数:11
相关论文
共 50 条
  • [1] Data consistency conditions for attenuation map alignment in pinhole cardiac SPECT
    Wells, R. Glenn
    Clackdoyle, Rolf
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [2] Attenuation correction in cardiac spect using consistency conditions
    da Silva, Ana Maria Marques
    Robilotta, Cecil Chow
    [J]. 2006 3RD IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1-3, 2006, : 271 - +
  • [3] Attenuation correction in SPECT using consistency conditions for the exponential ray transform
    Mennessier, C
    Noo, F
    Clackdoyle, R
    Bal, G
    Desbat, L
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (10): : 2483 - 2510
  • [4] Reconstruction of attenuation map using discrete consistency conditions
    Bronnikov, AV
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 451 - 462
  • [5] Attenuation-Emission Alignment in Cardiac PET/CT with Consistency Conditions
    Alessio, Adam
    Caldwell, James
    Chen, Grace
    Branch, Kelley
    Kinahan, Paul
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3288 - 3291
  • [6] Registration problem in attenuation map estimation using only emission data with data consistency conditions.
    Panin, VY
    Zeng, GL
    Gullberg, GT
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 294P - 294P
  • [7] Automatic Attenuation and Emission Alignment in Cardiac PET/CT Based on Consistency Conditions
    Alessio, A. M.
    Caldwell, J. H.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (04) : 665 - 665
  • [8] Attenuation-emission alignment in cardiac PET/CT based on consistency conditions
    Alessio, Adam M.
    Kinahan, Paul E.
    Champley, Kyle M.
    Caldwell, James H.
    [J]. MEDICAL PHYSICS, 2010, 37 (03) : 1191 - 1200
  • [9] Techniques for generating attenuation map using cardiac SPECT emission data only: a systematic review
    Getu Ferenji Tadesse
    Parham Geramifar
    Eyachew Misganew Tegaw
    Mohammad Reza Ay
    [J]. Annals of Nuclear Medicine, 2019, 33 : 1 - 13
  • [10] Techniques for generating attenuation map using cardiac SPECT emission data only: a systematic review
    Tadesse, Getu Ferenji
    Geramifar, Parham
    Tegaw, Eyachew Misganew
    Ay, Mohammad Reza
    [J]. ANNALS OF NUCLEAR MEDICINE, 2019, 33 (01) : 1 - 13