Computational hip joint simulator for wear and heat generation

被引:75
|
作者
Fialho, Jorge C.
Fernandes, Paulo R. [1 ]
Eca, Luis
Folgado, Joao
机构
[1] IDMEC IST, Lisbon, Portugal
[2] DEM IST, Lisbon, Portugal
关键词
hip joint; acetabular wear; heat generation; contact; finite elements;
D O I
10.1016/j.jbiomech.2006.12.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a computational simulator for the hip to compute the wear and heat generation on artificial joints. The friction produced on artificial hip joints originates wear rates that can lead to failure of the implant. Furthermore, the frictional heating can increase the wear. The developed computational model calculates the wear in the joint and the temperature in the surrounding zone, allowing the use of different combinations of joint materials, daily activities and different individuals. The pressure distribution on the joint bearing surfaces is obtained with the solution of a contact model. The heat generation by friction and the volumetric wear is computed from the pressure distribution and the sliding distance. The temperature is obtained from the solution of a transient heat conduction problem that includes the time-dependent heat generated by friction. The contact and heat conduction problems are solved numerically with the Finite Element Method. The developed computational model performs a full simulation of the acetabular bearing surface behaviour, which is useful for acetabular cup design and material selection. The results obtained by the present model agree with experimental and clinical data, as well as other numerical studies. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2358 / 2366
页数:9
相关论文
共 50 条
  • [41] Wear behaviour and wear debris characterization of UHMWPE on alumina ceramic, stainless steel, CoCrMo and Ti6Al4V hip prostheses in a hip joint simulator
    Shibo W.
    Shirong G.
    Hongtao L.
    Huang X.
    Journal of Biomimetics, Biomaterials, and Tissue Engineering, 2010, 7 (01): : 7 - 25
  • [42] Comparison of standard model and HIP-simulator examinations on wear and tear protection coats for metal-ceramic matchings in hip joint endoprosthesis
    Hartelt, M.
    Wäsche, R.
    Djahanbaksh, M.
    Österle, W.
    Tribologie und Schmierungstechnik, 2008, 55 (01): : 21 - 25
  • [43] Computational model of asperity contact for the prediction of UHMWPE mechanical and wear behaviour in total hip joint replacements
    N. Suhendra
    G.W. Stachowiak
    Tribology Letters, 2007, 25 : 9 - 22
  • [44] Computational model of asperity contact for the prediction of UHMWPE mechanical and wear behaviour in total hip joint replacements
    Suhendra, N.
    Stachowiak, G. W.
    TRIBOLOGY LETTERS, 2007, 25 (01) : 8 - 22
  • [45] Wear simulator study of the tripolar all ceramic hip prosthesis
    Jennings, L. M.
    Fisher, J.
    Stewart, T. D.
    Masson, B.
    Lazennec, J. -Y.
    Bioceramics and Alternative Bearings in Joint Arthroplasty, 2006, : 307 - 308
  • [46] Backside wear in acetabular hip joint replacement
    Braun, Steffen
    Sonntag, Robert
    Schroeder, Stefan
    Mueller, Ulrike
    Jaeger, Sebastian
    Gotterbarm, Tobias
    Kretzer, Jan Philippe
    ACTA BIOMATERIALIA, 2019, 83 : 467 - 476
  • [47] WEAR OF PLASTICS MATERIALS IN HIP-JOINT
    CHARNLEY, J
    PLASTICS AND RUBBER, 1976, 1 (02): : 59 - 63
  • [48] The Effect of Serum Protein Concentration on Wear Rates in a Hip Simulator
    John, Kenneth St.
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2010, 25 (02) : 145 - 159
  • [49] Design of a Hip Joint Simulator According to the ISO 14242
    Galanis, Nikolaos I.
    Manolakos, Dimitrios E.
    WORLD CONGRESS ON ENGINEERING, WCE 2011, VOL III, 2011, : 2088 - 2093
  • [50] Computational modelling of polyethylene wear and creep in total hip joint replacements: Effect of the bearing clearance and diameter
    Liu, Feng
    Fisher, John
    Jin, Zhongmin
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART J-JOURNAL OF ENGINEERING TRIBOLOGY, 2012, 226 (J6) : 552 - 563