Computational hip joint simulator for wear and heat generation

被引:75
|
作者
Fialho, Jorge C.
Fernandes, Paulo R. [1 ]
Eca, Luis
Folgado, Joao
机构
[1] IDMEC IST, Lisbon, Portugal
[2] DEM IST, Lisbon, Portugal
关键词
hip joint; acetabular wear; heat generation; contact; finite elements;
D O I
10.1016/j.jbiomech.2006.12.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a computational simulator for the hip to compute the wear and heat generation on artificial joints. The friction produced on artificial hip joints originates wear rates that can lead to failure of the implant. Furthermore, the frictional heating can increase the wear. The developed computational model calculates the wear in the joint and the temperature in the surrounding zone, allowing the use of different combinations of joint materials, daily activities and different individuals. The pressure distribution on the joint bearing surfaces is obtained with the solution of a contact model. The heat generation by friction and the volumetric wear is computed from the pressure distribution and the sliding distance. The temperature is obtained from the solution of a transient heat conduction problem that includes the time-dependent heat generated by friction. The contact and heat conduction problems are solved numerically with the Finite Element Method. The developed computational model performs a full simulation of the acetabular bearing surface behaviour, which is useful for acetabular cup design and material selection. The results obtained by the present model agree with experimental and clinical data, as well as other numerical studies. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2358 / 2366
页数:9
相关论文
共 50 条
  • [31] WEAR OF POLYETHYLENE ACETABULAR CUPS AGAINST ZIRCONIA FEMORAL HEADS STUDIED WITH A HIP-JOINT SIMULATOR
    SAIKKO, V
    WEAR, 1994, 176 (02) : 207 - 212
  • [32] NEW JOINT SIMULATOR FOR TOTAL HIP-JOINT PROSTHESIS
    SASADA, T
    MABUCHI, K
    MAEZAWA, H
    JOURNAL OF JAPAN SOCIETY OF LUBRICATION ENGINEERS, 1976, 21 (03): : 184 - 189
  • [33] Wear of artificial hip joint material
    Watters, EPJ
    Spedding, PL
    Grimshaw, J
    Duffy, JM
    Spedding, RL
    CHEMICAL ENGINEERING JOURNAL, 2005, 112 (1-3) : 137 - 144
  • [34] A five-station hip joint simulator
    Smith, SL
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H1) : 61 - 64
  • [35] The wear of metal-on-metal total hip prostheses measured in a hip simulator
    Scholes, SC
    Green, SM
    Unsworth, A
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H6) : 523 - 530
  • [36] Screening wear tester versus hip joint simulator: Results of UHMWPE sliding against different CoCrMo counterfaces
    Gonzalez-Mora, V
    Hoffmann, M
    Chiesa, R
    Cigada, A
    Hampshire, J
    Stroosnijder, MF
    SURFACE ENGINEERING, 2003, 19 (01) : 45 - 50
  • [37] A hip joint simulator study using simplified loading and motion cycles generating physiological wear paths and rates
    Barbour, PSM
    Stone, MH
    Fisher, J
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) : 455 - 467
  • [38] The influence of acetabular cup angle on the wear of “BIOLOX Forte” alumina ceramic bearing couples in a hip joint simulator
    J. E. Nevelos
    E. Ingham
    C. Doyle
    A. B. Nevelos
    J. Fisher
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 141 - 144
  • [39] The influence of acetabular cup angle on the wear of "BIOLOX Forte" alumina ceramic bearing couples in a hip joint simulator
    Nevelos, JE
    Ingham, E
    Doyle, C
    Nevelos, AB
    Fisher, J
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2001, 12 (02) : 141 - 144
  • [40] Generation of physiological parameter sets for hip joint motions and loads during daily life activities for application in wear simulators of the artificial hip joint
    Fabry, Christian
    Herrmann, Sven
    Kaehler, Michael
    Klinkenberg, Ernst-Dieter
    Woernle, Christoph
    Bader, Rainer
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (01) : 131 - 139