Myopic Laser Corneal Refractive Surgery Reduces Interdevice Agreement in the Measurement of Anterior Corneal Curvature

被引:6
|
作者
Jin, Haiying [1 ]
Ou, Zhongmin [2 ]
Guo, Haike [3 ]
Zhao, Peiquan [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Med Coll, Dept Ophthalmol, Kongjiang Rd, Shanghai 200092, Peoples R China
[2] Shanghai Univ, Dept Phys, Shanghai, Peoples R China
[3] Aier Eye Hosp, Dept Ophthalmol, Zhengzhou, Henan, Peoples R China
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2018年 / 44卷
基金
中国国家自然科学基金;
关键词
Laser corneal refractive surgery; Anterior corneal curvature measurement; Interdevice agreement; Corneal power; LENS POWER CALCULATION; EXCIMER-LASER; ORBSCAN-II; AUTOMATED KERATOMETRY; CATARACT-SURGERY; SCHEIMPFLUG; PENTACAM; TOMOGRAPHY; PLACIDO; REPEATABILITY;
D O I
10.1097/ICL.0000000000000364
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate interdevice differences and agreement in the measurement of anterior corneal curvature obtained by different technologies after laser corneal refractive surgery. Methods: The prospective study comprised 109 eyes of 109 consecutive patients who had undergone laser-assisted in situ keratomileusis (LASIK). Preoperative and postoperative corneal parameters were measured by Scheimpflug imaging (Pentacam), Placido-slit-scanning (Orbscan) and auto-keratometry (IOLMaster). Preoperative and postoperative anterior corneal curvatures (K readings) were compared between devices. Inter-device agreement was evaluated by Bland-Altman analysis. Results: Preoperatively, the difference of K reading for Pentacam-IOLMaster (0.04 +/- 0.20 D) was not statistically significant (P=0.059). The differences between Pentacam-Orbscan and Orbscan-IOLMaster were 0.20 +/- 0.34 D (P<0.001)and -0.17 +/- 0.29 D (P<0.001), respectively. After surgery, no difference was found for Pentacam-Orbscan (0.05 +/- 0.38, P=0.136). The differences between Pentacam-IOLMaster and Orbscan-IOLMaster were 0.13 +/- 0.29 D (P<0.001) and 0.19 +/- 0.34 D (P<0.001). Preoperative interdevice agreement (95% limit of agreement [LOA]) between Pentacam and Orbscan, Pentacam and IOLMaster, and Orbscan and IOLMaster were 1.31 D, 0.79 D and 1.14 D, respectively. The 95% LOAs decreased to 1.47 D, 1.14 D, and 1.34 D after refractive surgery. Conclusion: Corneal refractive surgery changed the preoperative and postoperative interdevice differences in corneal curvature measurements and reduced interdevice agreement, indicating that the devices are not interchangeable.
引用
收藏
页码:S151 / S157
页数:7
相关论文
共 50 条
  • [41] Corneal refractive power after myopic LASIK
    Feiz, V
    Mannis, MJ
    OPHTHALMOLOGY, 2003, 110 (09) : 1855 - 1856
  • [42] Calculations of actual corneal astigmatism using total corneal refractive power before and after myopic keratorefractive surgery
    Seo, Kyoung Yul
    Yang, Hun
    Kim, Wook Kyum
    Nam, Sang Min
    PLOS ONE, 2017, 12 (04):
  • [43] Intraocular lens power calculation using adjusted corneal power in eyes after myopic corneal refractive surgery
    Tan, Qian
    Lin, Ding
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [44] A multicenter study of the distribution pattern of posterior corneal astigmatism in Chinese myopic patients having corneal refractive surgery
    Yijun Hu
    Shanqing Zhu
    Lu Xiong
    Xuejun Fang
    Jia Liu
    Jin Zhou
    Fangfang Li
    Qingsong Zhang
    Na Huang
    Xiaohua Lei
    Li Jiang
    Zheng Wang
    Scientific Reports, 10
  • [45] Evaluation of anterior chamber inflammation after corneal refractive surgery
    Pisella, PJ
    Albou-Ganem, C
    Bourges, JL
    Debbasch, C
    Limon, S
    CORNEA, 1999, 18 (03) : 302 - 305
  • [46] Finite element simulations of laser refractive corneal surgery
    Pandolfi, Anna
    Fotia, Giorgio
    Manganiello, Federico
    ENGINEERING WITH COMPUTERS, 2009, 25 (01) : 15 - 24
  • [47] VisuMax (R) femtosecond laser for corneal refractive surgery
    Montes-Mico, Robert
    Cervino, Alejandro
    Ferrer-Blasco, Teresa
    EXPERT REVIEW OF OPHTHALMOLOGY, 2008, 3 (04) : 385 - 388
  • [48] Corneal neuromediator profiles following laser refractive surgery
    Yang, Lily Wei Yun
    Mehta, Jodhbir S.
    Liu, Yu-Chi
    NEURAL REGENERATION RESEARCH, 2021, 16 (11) : 2177 - 2183
  • [49] Microbial keratitis after corneal laser refractive surgery
    Sharma, Daya Papalkar
    Sharma, Shanel
    Wilkins, Mark R.
    FUTURE MICROBIOLOGY, 2011, 6 (07) : 819 - 831
  • [50] Corneal neuromediator profiles following laser refractive surgery
    Lily Wei Yun Yang
    Jodhbir S.Mehta
    Yu-Chi Liu
    NeuralRegenerationResearch, 2021, 16 (11) : 2177 - 2183