Myopic Laser Corneal Refractive Surgery Reduces Interdevice Agreement in the Measurement of Anterior Corneal Curvature

被引:6
|
作者
Jin, Haiying [1 ]
Ou, Zhongmin [2 ]
Guo, Haike [3 ]
Zhao, Peiquan [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Med Coll, Dept Ophthalmol, Kongjiang Rd, Shanghai 200092, Peoples R China
[2] Shanghai Univ, Dept Phys, Shanghai, Peoples R China
[3] Aier Eye Hosp, Dept Ophthalmol, Zhengzhou, Henan, Peoples R China
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2018年 / 44卷
基金
中国国家自然科学基金;
关键词
Laser corneal refractive surgery; Anterior corneal curvature measurement; Interdevice agreement; Corneal power; LENS POWER CALCULATION; EXCIMER-LASER; ORBSCAN-II; AUTOMATED KERATOMETRY; CATARACT-SURGERY; SCHEIMPFLUG; PENTACAM; TOMOGRAPHY; PLACIDO; REPEATABILITY;
D O I
10.1097/ICL.0000000000000364
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate interdevice differences and agreement in the measurement of anterior corneal curvature obtained by different technologies after laser corneal refractive surgery. Methods: The prospective study comprised 109 eyes of 109 consecutive patients who had undergone laser-assisted in situ keratomileusis (LASIK). Preoperative and postoperative corneal parameters were measured by Scheimpflug imaging (Pentacam), Placido-slit-scanning (Orbscan) and auto-keratometry (IOLMaster). Preoperative and postoperative anterior corneal curvatures (K readings) were compared between devices. Inter-device agreement was evaluated by Bland-Altman analysis. Results: Preoperatively, the difference of K reading for Pentacam-IOLMaster (0.04 +/- 0.20 D) was not statistically significant (P=0.059). The differences between Pentacam-Orbscan and Orbscan-IOLMaster were 0.20 +/- 0.34 D (P<0.001)and -0.17 +/- 0.29 D (P<0.001), respectively. After surgery, no difference was found for Pentacam-Orbscan (0.05 +/- 0.38, P=0.136). The differences between Pentacam-IOLMaster and Orbscan-IOLMaster were 0.13 +/- 0.29 D (P<0.001) and 0.19 +/- 0.34 D (P<0.001). Preoperative interdevice agreement (95% limit of agreement [LOA]) between Pentacam and Orbscan, Pentacam and IOLMaster, and Orbscan and IOLMaster were 1.31 D, 0.79 D and 1.14 D, respectively. The 95% LOAs decreased to 1.47 D, 1.14 D, and 1.34 D after refractive surgery. Conclusion: Corneal refractive surgery changed the preoperative and postoperative interdevice differences in corneal curvature measurements and reduced interdevice agreement, indicating that the devices are not interchangeable.
引用
收藏
页码:S151 / S157
页数:7
相关论文
共 50 条
  • [31] Modeling the biomechanics of laser corneal refractive surgery
    Montanino, Andrea
    van Overbeeke, Sanne
    Pandolfi, Anna
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 145
  • [32] Emmetropization and optical aberrations in a myopic corneal refractive surgery chick model
    de la Cera, E. Garcia
    Rodriguez, G.
    de Castro, A.
    Merayo, J.
    Marcos, S.
    VISION RESEARCH, 2007, 47 (18) : 2465 - 2472
  • [33] Anterior and Posterior Corneal Astigmatism after Refractive Lenticule Extraction for Myopic Astigmatism
    Kamiya, Kazutaka
    Shimizu, Kimiya
    Yamagishi, Mayumi
    Igarashi, Akihito
    Kobashi, Hidenaga
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [34] Posterior corneal curvature changes after myopic laser in situ keratomileusis
    Seitz, B
    Torres, F
    Langenbucher, A
    Behrens, A
    Suárez, E
    OPHTHALMOLOGY, 2001, 108 (04) : 666 - 672
  • [35] REFRACTIVE CORNEAL SURGERY
    STEELE, ADM
    OPHTHALMOLOGY TODAY, 1988, 803 : 141 - 144
  • [36] REFRACTIVE CORNEAL SURGERY
    GNAD, HD
    WIENER KLINISCHE WOCHENSCHRIFT, 1985, 97 (15) : 613 - 615
  • [37] New Scheimpflug camera device in measuring corneal power changes after myopic laser refractive surgery
    Lanza, Michele
    Iaccarino, Stefania
    Cennamo, Michela
    Lanza, Alessandro
    Coen, Giovanni
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (02): : 115 - 119
  • [38] Change to corneal morphology after refractive surgery (myopic laser in situ keratomileusis) as viewed with a confocal microscope
    Perez-Gomez, I
    Efron, N
    OPTOMETRY AND VISION SCIENCE, 2003, 80 (10) : 690 - 697
  • [39] Algorithm for Correcting the Keratometric Error in the Estimation of the Corneal Power in Eyes With Previous Myopic Laser Refractive Surgery
    Camps, Vicente J.
    Pinero, David P.
    Mateo, Veronica
    Ribera, David
    de Fez, Dolores
    Blanes-Mompo, Francisco J.
    Alzamora-Rodriguez, Antonio
    CORNEA, 2013, 32 (11) : 1454 - 1459
  • [40] Correlation between refractive and measured corneal power changes after myopic excimer laser photorefractive surgery
    Chen, S
    Hu, FR
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (04): : 603 - 610