Myopic Laser Corneal Refractive Surgery Reduces Interdevice Agreement in the Measurement of Anterior Corneal Curvature

被引:6
|
作者
Jin, Haiying [1 ]
Ou, Zhongmin [2 ]
Guo, Haike [3 ]
Zhao, Peiquan [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Med Coll, Dept Ophthalmol, Kongjiang Rd, Shanghai 200092, Peoples R China
[2] Shanghai Univ, Dept Phys, Shanghai, Peoples R China
[3] Aier Eye Hosp, Dept Ophthalmol, Zhengzhou, Henan, Peoples R China
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2018年 / 44卷
基金
中国国家自然科学基金;
关键词
Laser corneal refractive surgery; Anterior corneal curvature measurement; Interdevice agreement; Corneal power; LENS POWER CALCULATION; EXCIMER-LASER; ORBSCAN-II; AUTOMATED KERATOMETRY; CATARACT-SURGERY; SCHEIMPFLUG; PENTACAM; TOMOGRAPHY; PLACIDO; REPEATABILITY;
D O I
10.1097/ICL.0000000000000364
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate interdevice differences and agreement in the measurement of anterior corneal curvature obtained by different technologies after laser corneal refractive surgery. Methods: The prospective study comprised 109 eyes of 109 consecutive patients who had undergone laser-assisted in situ keratomileusis (LASIK). Preoperative and postoperative corneal parameters were measured by Scheimpflug imaging (Pentacam), Placido-slit-scanning (Orbscan) and auto-keratometry (IOLMaster). Preoperative and postoperative anterior corneal curvatures (K readings) were compared between devices. Inter-device agreement was evaluated by Bland-Altman analysis. Results: Preoperatively, the difference of K reading for Pentacam-IOLMaster (0.04 +/- 0.20 D) was not statistically significant (P=0.059). The differences between Pentacam-Orbscan and Orbscan-IOLMaster were 0.20 +/- 0.34 D (P<0.001)and -0.17 +/- 0.29 D (P<0.001), respectively. After surgery, no difference was found for Pentacam-Orbscan (0.05 +/- 0.38, P=0.136). The differences between Pentacam-IOLMaster and Orbscan-IOLMaster were 0.13 +/- 0.29 D (P<0.001) and 0.19 +/- 0.34 D (P<0.001). Preoperative interdevice agreement (95% limit of agreement [LOA]) between Pentacam and Orbscan, Pentacam and IOLMaster, and Orbscan and IOLMaster were 1.31 D, 0.79 D and 1.14 D, respectively. The 95% LOAs decreased to 1.47 D, 1.14 D, and 1.34 D after refractive surgery. Conclusion: Corneal refractive surgery changed the preoperative and postoperative interdevice differences in corneal curvature measurements and reduced interdevice agreement, indicating that the devices are not interchangeable.
引用
收藏
页码:S151 / S157
页数:7
相关论文
共 50 条
  • [21] Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks
    Koprowski, Robert
    Lanza, Michele
    Irregolare, Carlo
    BIOMEDICAL ENGINEERING ONLINE, 2016, 15
  • [22] Corneal power evaluation after myopic corneal refractive surgery using artificial neural networks
    Robert Koprowski
    Michele Lanza
    Carlo Irregolare
    BioMedical Engineering OnLine, 15
  • [23] Estimation of corneal power after myopic laser refractive surgery: Comparison of methods against back-calculated corneal power
    Tay, Eugene
    Lim, Cindy
    Gimbel, Howard
    Kaye, Geoffrey
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11): : 1945 - 1950
  • [24] Evaluation of Corneal Biomechanics After Excimer Laser Corneal Refractive Surgery in High Myopic Patients Using Dynamic Scheimpflug Technology
    Hashemi, Hassan
    Asgari, Soheila
    Mortazavi, Mahdi
    Ghaffari, Reza
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (06): : 371 - 377
  • [25] Corneal Inflammation Following Corneal Photoablative Refractive Surgery With Excimer Laser
    Alio, Jorge L.
    Javaloy, Jaime
    SURVEY OF OPHTHALMOLOGY, 2013, 58 (01) : 11 - 25
  • [26] Clinical Evaluation of Corneal Endothelial Parameters following Laser Refractive Surgery in Myopic Eyes: A Review
    Juda, Maciej
    Bedlinski, Maciej
    Roszkowska, Anna Maria
    Wierzbowska, Joanna
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (06)
  • [27] Clinical Evaluation of Corneal Biomechanics following Laser Refractive Surgery in Myopic Eyes: A Review of the Literature
    Pniakowska, Zofia
    Jurowski, Piotr
    Wierzbowska, Joanna
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
  • [28] The evolution of corneal and refractive surgery with the femtosecond laser
    Aristeidou, Antonis
    Taniguchi, Elise V.
    Tsatsos, Michael
    Muller, Rodrigo
    McAlinden, Colm
    Pineda, Roberto
    Paschalis, Eleftherios I.
    EYE AND VISION, 2015, 2
  • [29] The evolution of corneal and refractive surgery with the femtosecond laser
    Antonis Aristeidou
    Elise V. Taniguchi
    Michael Tsatsos
    Rodrigo Muller
    Colm McAlinden
    Roberto Pineda
    Eleftherios I. Paschalis
    Eye and Vision, 2
  • [30] Applications of the femtosecond laser in corneal refractive surgery
    Kim, Peter
    Sutton, Gerard L.
    Rootman, David S.
    CURRENT OPINION IN OPHTHALMOLOGY, 2011, 22 (04) : 238 - 244