Myopic Laser Corneal Refractive Surgery Reduces Interdevice Agreement in the Measurement of Anterior Corneal Curvature

被引:6
|
作者
Jin, Haiying [1 ]
Ou, Zhongmin [2 ]
Guo, Haike [3 ]
Zhao, Peiquan [1 ]
机构
[1] Shanghai Jiao Tong Univ, Xinhua Hosp, Med Coll, Dept Ophthalmol, Kongjiang Rd, Shanghai 200092, Peoples R China
[2] Shanghai Univ, Dept Phys, Shanghai, Peoples R China
[3] Aier Eye Hosp, Dept Ophthalmol, Zhengzhou, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Laser corneal refractive surgery; Anterior corneal curvature measurement; Interdevice agreement; Corneal power; LENS POWER CALCULATION; EXCIMER-LASER; ORBSCAN-II; AUTOMATED KERATOMETRY; CATARACT-SURGERY; SCHEIMPFLUG; PENTACAM; TOMOGRAPHY; PLACIDO; REPEATABILITY;
D O I
10.1097/ICL.0000000000000364
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To investigate interdevice differences and agreement in the measurement of anterior corneal curvature obtained by different technologies after laser corneal refractive surgery. Methods: The prospective study comprised 109 eyes of 109 consecutive patients who had undergone laser-assisted in situ keratomileusis (LASIK). Preoperative and postoperative corneal parameters were measured by Scheimpflug imaging (Pentacam), Placido-slit-scanning (Orbscan) and auto-keratometry (IOLMaster). Preoperative and postoperative anterior corneal curvatures (K readings) were compared between devices. Inter-device agreement was evaluated by Bland-Altman analysis. Results: Preoperatively, the difference of K reading for Pentacam-IOLMaster (0.04 +/- 0.20 D) was not statistically significant (P=0.059). The differences between Pentacam-Orbscan and Orbscan-IOLMaster were 0.20 +/- 0.34 D (P<0.001)and -0.17 +/- 0.29 D (P<0.001), respectively. After surgery, no difference was found for Pentacam-Orbscan (0.05 +/- 0.38, P=0.136). The differences between Pentacam-IOLMaster and Orbscan-IOLMaster were 0.13 +/- 0.29 D (P<0.001) and 0.19 +/- 0.34 D (P<0.001). Preoperative interdevice agreement (95% limit of agreement [LOA]) between Pentacam and Orbscan, Pentacam and IOLMaster, and Orbscan and IOLMaster were 1.31 D, 0.79 D and 1.14 D, respectively. The 95% LOAs decreased to 1.47 D, 1.14 D, and 1.34 D after refractive surgery. Conclusion: Corneal refractive surgery changed the preoperative and postoperative interdevice differences in corneal curvature measurements and reduced interdevice agreement, indicating that the devices are not interchangeable.
引用
收藏
页码:S151 / S157
页数:7
相关论文
共 50 条
  • [1] Corneal Epithelium Thickness and Refractive Changes After Myopic Laser Corneal Refractive Surgery
    Canto-Cerdan, Mario
    El Bahrawy, Mohamed
    Alio, Jorge L.
    Casanova, Laura
    Garcia, Maria J.
    Al-Amri, Saad Abdulrahman J.
    Cavas, Francisco
    Alio del Barrio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (09) : 602 - +
  • [2] The change in internal aberrations following myopic corneal laser refractive surgery
    Colm McAlinden
    Jonathan E. Moore
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 775 - 781
  • [3] Corneal Morphological Changes After Myopic Excimer Laser Refractive Surgery
    Rosa, Nicola
    Borrelli, Maria
    De Bernardo, Maddalena
    Lanza, Michele
    CORNEA, 2011, 30 (02) : 130 - 135
  • [4] The change in internal aberrations following myopic corneal laser refractive surgery
    McAlinden, Colm
    Moore, Jonathan E.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (05) : 775 - 781
  • [5] Algorithm for the Estimation of the Corneal Power in Eyes With Previous Myopic Laser Refractive Surgery
    De Bernardo, Maddalena
    Capasso, Luigi
    Rosa, Nicola
    CORNEA, 2014, 33 (06) : E2 - E2
  • [6] Influence of patient age on high myopic correction in corneal laser refractive surgery
    Luger, Michiel H. A.
    Ewering, Tobias
    Arba-Mosquera, Samuel
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (02): : 204 - 210
  • [7] Corneal stromal thickness changes after myopic laser cornea refractive surgery
    Del Barrio, Jorge L. Alio
    Canto-Cerdan, Mario
    El Bahrawy, Mohamed
    Casanova, Laura
    Garcia, Maria J.
    Cavas, Francisco
    Alio, Jorge L.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (03): : 334 - 341
  • [8] Optimum corneal asphericity of myopic eyes for refractive surgery
    Díaz, JA
    Anera, RG
    Jiménez, JR
    del Barco, LJ
    JOURNAL OF MODERN OPTICS, 2003, 50 (12) : 1903 - 1915
  • [9] Effects of error in radius of curvature on the corneal power measurement before and after laser refractive surgery for myopia
    Liu, Yongji
    Wang, Yan
    Wang, Zhaoqi
    Zuo, Tong
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2012, 32 (04) : 355 - 361
  • [10] Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes
    Hua, Yanjun
    Pan, Chao
    Wang, Qinmei
    INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2467 - 2475