A gas-phase amplified quartz crystal microbalance immunosensor based on catalase modified immunoparticles

被引:7
|
作者
Liu, Wei [1 ]
Huang, Renliang [2 ]
Qi, Wei [1 ,3 ,4 ]
Wang, Mengfan [1 ,4 ]
Su, Rongxin [1 ,3 ,4 ]
He, Zhimin [1 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, State Key Lab Chem Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[3] Coinnovat Ctr Chem & Chem Engn Tianjin, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Membrane Sci & Desalinat Technol, Tianjin 300072, Peoples R China
关键词
SURFACE-PLASMON RESONANCE; PIEZOELECTRIC IMMUNOSENSOR; SIGNAL AMPLIFICATION; SENSITIVE DETECTION; QCM IMMUNOSENSOR; ASSAY; BIOSENSOR; SENSOR; APTASENSOR; FREQUENCY;
D O I
10.1039/c4an02061h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel signal amplification strategy for quartz crystal microbalance (QCM) based on catalytic gas generation was developed to construct an ultrasensitive immunosensor for the detection of proteins (immunoglobulin G, IgG, used as a model). A catalase modified immunoparticle was prepared to form a sandwich-type immunocomplex with the IgG and anti-IgG antibodies that were immobilized on the QCM sensor. The amount of immunoparticles on the sensor surface was thus controlled by the IgG concentration. Then H2O2 was added and catalyzed by catalase for oxygen generation. The generated oxygen replaced some of the liquid on the sensor surface, leading to the change in the shear modulus of the immunocomplex layer and the apparent viscosity and density of the liquid layer. Due to the ultrasensitive response of QCM to these changes, a significant frequency shift related to the IgG concentration was achieved. Different parameters, including the flow cell structure, operation temperature, immunoparticle concentration, and H2O2 concentration were optimized to achieve steady and efficient frequency shifts. Under the optimal conditions, the proposed gas-phase amplified QCM sensor could achieve up to 72 times improvement of detection sensitivity compared to the label-free sensor as a control, in the concentration range of 0.1-3.0 mu g mL(-1). The detection limit was also reduced from 236 ng mL(-1) to 51.0 ng mL(-1) at the 3S(blank) level.
引用
收藏
页码:1174 / 1181
页数:8
相关论文
共 50 条
  • [41] Immunosensor for Detection of Inhibitory Neurotransmitter γ-Aminobutyric Acid Using Quartz Crystal Microbalance
    Wang, Tingting
    Muthuswamy, Jit
    ANALYTICAL CHEMISTRY, 2008, 80 (22) : 8576 - 8582
  • [42] Quartz crystal microbalance immunosensor for the detection of antibodies to double-stranded DNA
    Rawil F. Fakhrullin
    Victor G. Vinter
    Alsu I. Zamaleeva
    Maria V. Matveeva
    Roustem A. Kourbanov
    Belayhun K. Temesgen
    Dilara G. Ishmuchametova
    Zinaida I. Abramova
    Olga A. Konovalova
    Myakzyum K. Salakhov
    Analytical and Bioanalytical Chemistry, 2007, 388 : 367 - 375
  • [43] Quartz crystal microbalance immunosensor for the detection of antibodies to double-stranded DNA
    Fakhrullin, Rawil F.
    Vinter, Victor G.
    Zamaleeva, Alsu I.
    Matveeva, Maria V.
    Kourbanov, Roustem A.
    Temesgen, Belayhun K.
    Ishmuchametova, Dilara G.
    Abramova, Zinaida I.
    Konovalova, Olga A.
    Salakhov, Myakzyum K.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (02) : 367 - 375
  • [44] Out-of-plane vibrations of quartz resonators used in quartz crystal microbalance measurements in gas phase
    Mecea, VM
    Carlsson, JO
    Alm, O
    Boman, M
    SENSORS AND ACTUATORS A-PHYSICAL, 2006, 125 (02) : 143 - 147
  • [45] Quartz crystal microbalance with gold electrodes as a sensor for monitoring gas-phase adsorption/desorption of short chain alkylthiol and alkyl sulfides
    Rocha, TAP
    Gomes, MTSR
    Duarte, AC
    Oliveira, JABP
    ANALYTICAL COMMUNICATIONS, 1998, 35 (12): : 415 - 416
  • [46] Formaldehyde gas sensors based on a quartz crystal microbalance modified with aniline-doped polyvinyl acetate nanofibers
    Sofa, Sintia Ainus
    Roto, Roto
    Aflaha, Rizky
    Natsir, Taufik Abdillah
    Humairah, Nur Aisyah
    Kusumaatmaja, Ahmad
    Triyana, Kuwat
    Gupta, Ruchi
    ANALYST, 2024, 149 (04) : 1262 - 1270
  • [47] Development of an Electrochemical Quartz Crystal Microbalance-Based Immunosensor for C-reactive protein determination
    Gao, Kai
    Cui, Song
    Liu, Sibo
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (01): : 812 - 821
  • [48] SPICE model for quartz crystal microbalance gas sensors
    Polo, J
    Llobet, E
    Vilanova, X
    Brezmes, J
    Correig, X
    ELECTRONICS LETTERS, 1999, 35 (10) : 772 - 773
  • [49] Quartz crystal microbalance dewpoint sensor for natural gas
    Shapiro, AP
    Dean, AJ
    INTERNAL STANDARDIZATION AND CALIBRATION ARCHITECTURES FOR CHEMICAL SENSORS, 1999, 3856 : 148 - 159
  • [50] Graphite microparticles as coatings for quartz crystal microbalance-based gas sensors
    Shinar, R
    Liu, GJ
    Porter, MD
    ANALYTICAL CHEMISTRY, 2000, 72 (24) : 5981 - 5987