A gas-phase amplified quartz crystal microbalance immunosensor based on catalase modified immunoparticles

被引:7
|
作者
Liu, Wei [1 ]
Huang, Renliang [2 ]
Qi, Wei [1 ,3 ,4 ]
Wang, Mengfan [1 ,4 ]
Su, Rongxin [1 ,3 ,4 ]
He, Zhimin [1 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, State Key Lab Chem Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[3] Coinnovat Ctr Chem & Chem Engn Tianjin, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Membrane Sci & Desalinat Technol, Tianjin 300072, Peoples R China
关键词
SURFACE-PLASMON RESONANCE; PIEZOELECTRIC IMMUNOSENSOR; SIGNAL AMPLIFICATION; SENSITIVE DETECTION; QCM IMMUNOSENSOR; ASSAY; BIOSENSOR; SENSOR; APTASENSOR; FREQUENCY;
D O I
10.1039/c4an02061h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel signal amplification strategy for quartz crystal microbalance (QCM) based on catalytic gas generation was developed to construct an ultrasensitive immunosensor for the detection of proteins (immunoglobulin G, IgG, used as a model). A catalase modified immunoparticle was prepared to form a sandwich-type immunocomplex with the IgG and anti-IgG antibodies that were immobilized on the QCM sensor. The amount of immunoparticles on the sensor surface was thus controlled by the IgG concentration. Then H2O2 was added and catalyzed by catalase for oxygen generation. The generated oxygen replaced some of the liquid on the sensor surface, leading to the change in the shear modulus of the immunocomplex layer and the apparent viscosity and density of the liquid layer. Due to the ultrasensitive response of QCM to these changes, a significant frequency shift related to the IgG concentration was achieved. Different parameters, including the flow cell structure, operation temperature, immunoparticle concentration, and H2O2 concentration were optimized to achieve steady and efficient frequency shifts. Under the optimal conditions, the proposed gas-phase amplified QCM sensor could achieve up to 72 times improvement of detection sensitivity compared to the label-free sensor as a control, in the concentration range of 0.1-3.0 mu g mL(-1). The detection limit was also reduced from 236 ng mL(-1) to 51.0 ng mL(-1) at the 3S(blank) level.
引用
收藏
页码:1174 / 1181
页数:8
相关论文
共 50 条
  • [31] Label-Free Detection of Gliadin in Food by Quartz Crystal Microbalance-Based Immunosensor
    Funari, Riccardo
    Terracciano, Irma
    Della Ventura, Bartolomeo
    Ricci, Sara
    Cardi, Teodoro
    D'Agostino, Nunzio
    Velotta, Raffaele
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2017, 65 (06) : 1281 - 1289
  • [32] A Point-of-Care Immunosensor Based on a Quartz Crystal Microbalance with Graphene Biointerface for Antibody Assay
    Hampitak, Piramon
    Jowitt, Thomas A.
    Melendrez, Daniel
    Fresquet, Maryline
    Hamilton, Patrick
    Iliut, Maria
    Nie, Kaiwen
    Spencer, Ben
    Lennon, Rachel
    Vijayaraghavan, Aravind
    ACS SENSORS, 2020, 5 (11) : 3520 - 3532
  • [33] Response of a Quartz Crystal Microbalance Sensor Coated with a Viscoelastic Film in Gas Phase
    Tan, Feng
    Huang, Xianhe
    SENSOR LETTERS, 2013, 11 (10) : 2000 - 2004
  • [34] Polyaniline-Modified Quartz Crystal Microbalance Sensor for Detection of Formic Acid Gas
    Yan, Ying
    Lu, Dandan
    Zhou, Hao
    Hou, Haiping
    Zhang, Ting
    Wu, Laiming
    Cai, Lankun
    WATER AIR AND SOIL POLLUTION, 2012, 223 (03): : 1275 - 1280
  • [35] A Mica-Modified Quartz Resonator for a Quartz Crystal Microbalance Study
    Bo Xu
    Hongda Wang
    Ying Wang
    Guoyi Zhu
    Zhuang Li
    Erkang Wang
    Analytical Sciences, 2000, 16 : 1061 - 1063
  • [36] Polyaniline-Modified Quartz Crystal Microbalance Sensor for Detection of Formic Acid Gas
    Ying Yan
    Dandan Lu
    Hao Zhou
    Haiping Hou
    Ting Zhang
    Laiming Wu
    Lankun Cai
    Water, Air, & Soil Pollution, 2012, 223 : 1275 - 1280
  • [37] A mica-modified quartz resonator for a quartz crystal microbalance study
    Xu, B
    Wang, HD
    Wang, Y
    Zhu, GY
    Li, Z
    Wang, EK
    ANALYTICAL SCIENCES, 2000, 16 (10) : 1061 - 1063
  • [38] Direct-binding quartz crystal microbalance immunosensor to detect carp metallothionein
    Kim, N.
    Son, S. -H.
    Kim, C. -T.
    Cho, Y. -J.
    Kim, C. -J.
    Kim, W. Y.
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 627 - 634
  • [39] Ochratoxin A Detection by an Immunosensor Using Impedance Spectroscopy Coupled with Quartz Crystal Microbalance
    Cheap, H.
    Sanchez, M.
    Vivier, V.
    Perrot, H.
    Marty, J. L.
    SENSOR LETTERS, 2011, 9 (06) : 2312 - 2315
  • [40] High-frequency wireless and electrodeless quartz crystal microbalance developed as immunosensor
    Ogi, Hirotsugu
    Motohisa, Kazuma
    Hatanaka, Kenichi
    Ohmori, Toshinobu
    Hirao, Masahiko
    Nishiyama, Masayoshi
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (7B): : 4693 - 4697