A gas-phase amplified quartz crystal microbalance immunosensor based on catalase modified immunoparticles

被引:7
|
作者
Liu, Wei [1 ]
Huang, Renliang [2 ]
Qi, Wei [1 ,3 ,4 ]
Wang, Mengfan [1 ,4 ]
Su, Rongxin [1 ,3 ,4 ]
He, Zhimin [1 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, State Key Lab Chem Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[3] Coinnovat Ctr Chem & Chem Engn Tianjin, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Membrane Sci & Desalinat Technol, Tianjin 300072, Peoples R China
关键词
SURFACE-PLASMON RESONANCE; PIEZOELECTRIC IMMUNOSENSOR; SIGNAL AMPLIFICATION; SENSITIVE DETECTION; QCM IMMUNOSENSOR; ASSAY; BIOSENSOR; SENSOR; APTASENSOR; FREQUENCY;
D O I
10.1039/c4an02061h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel signal amplification strategy for quartz crystal microbalance (QCM) based on catalytic gas generation was developed to construct an ultrasensitive immunosensor for the detection of proteins (immunoglobulin G, IgG, used as a model). A catalase modified immunoparticle was prepared to form a sandwich-type immunocomplex with the IgG and anti-IgG antibodies that were immobilized on the QCM sensor. The amount of immunoparticles on the sensor surface was thus controlled by the IgG concentration. Then H2O2 was added and catalyzed by catalase for oxygen generation. The generated oxygen replaced some of the liquid on the sensor surface, leading to the change in the shear modulus of the immunocomplex layer and the apparent viscosity and density of the liquid layer. Due to the ultrasensitive response of QCM to these changes, a significant frequency shift related to the IgG concentration was achieved. Different parameters, including the flow cell structure, operation temperature, immunoparticle concentration, and H2O2 concentration were optimized to achieve steady and efficient frequency shifts. Under the optimal conditions, the proposed gas-phase amplified QCM sensor could achieve up to 72 times improvement of detection sensitivity compared to the label-free sensor as a control, in the concentration range of 0.1-3.0 mu g mL(-1). The detection limit was also reduced from 236 ng mL(-1) to 51.0 ng mL(-1) at the 3S(blank) level.
引用
收藏
页码:1174 / 1181
页数:8
相关论文
共 50 条
  • [21] DEVELOPMENT OF QUARTZ CRYSTAL MICROBALANCE-BASED IMMUNOSENSOR FOR DETECTING ALPHA-FETOPROTEIN
    Huang, Ke-Nung
    Shen, Chi-Yen
    Wang, Shih-Han
    Hung, Chih-Hsin
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2013, 41 (03) : 311 - 324
  • [22] A Label-Free Immunosensor for Ultrasensitive Detection of Ketamine Based on Quartz Crystal Microbalance
    Yang, Ya
    Tu, Yifeng
    Wang, Xiaoshu
    Pan, Jinyin
    Ding, Yun
    SENSORS, 2015, 15 (04): : 8540 - 8549
  • [23] Development of a quartz crystal microbalance-based immunosensor for the early detection of mesothelin in cancer
    Joshi H.C.
    Kharkwal H.
    Kumar A.
    Gupta P.K.
    Sensors International, 2023, 4
  • [24] Fabrication of diamond based quartz crystal microbalance gas sensor
    Varga, Marian
    Laposa, Alexandr
    Kulha, Pavel
    Davydova, M.
    Kroutil, Jiri
    Husak, Miroslav
    Kromka, Alexander
    MATERIALS AND APPLICATIONS FOR SENSORS AND TRANSDUCERS III, 2014, 605 : 589 - 592
  • [25] AMPLIFIED MASS IMMUNOSORBENT-ASSAY WITH A QUARTZ CRYSTAL MICROBALANCE
    EBERSOLE, RC
    WARD, MD
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (26) : 8623 - 8628
  • [26] Effective Gas Sensing Using Quartz Crystal Microbalance Modified With Polymer Nanobrushes
    Kimura, Mutsumi
    Mihara, Takashi
    Fukawa, Tadashi
    POLYMER-BASED SMART MATERIALS - PROCESSES, PROPERTIES AND APPLICATION, 2009, 1134 : 115 - 120
  • [27] Development of a quartz crystal microbalance (QCM) immunosensor for the detection of Listeria monocytogenes
    Vaughan, RD
    O'Sullivan, CK
    Guilbault, GG
    ENZYME AND MICROBIAL TECHNOLOGY, 2001, 29 (10) : 635 - 638
  • [28] Multichannel Wireless-Electrodeless Quartz-Crystal Microbalance Immunosensor
    Ogi, Hirotsugu
    Nagai, Hironao
    Fukunishi, Yuji
    Yanagida, Taiji
    Hirao, Masahiko
    Nishiyama, Masayoshi
    ANALYTICAL CHEMISTRY, 2010, 82 (09) : 3957 - 3962
  • [29] Quartz crystal microbalance immunosensor for the quantification of immunoglobulin G in bovine milk
    Crosson, Cyril
    Rossi, Claire
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 453 - 459
  • [30] Quartz crystal microbalance-based unlabeled immunosensor for the determination of aflatoxin B1
    Slavova, M. P.
    Georgieva-Nikolova, R. T.
    Nikolova, M. M.
    Hadjiolova, R. K.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2016, 48 (04): : 689 - 693