A gas-phase amplified quartz crystal microbalance immunosensor based on catalase modified immunoparticles

被引:7
|
作者
Liu, Wei [1 ]
Huang, Renliang [2 ]
Qi, Wei [1 ,3 ,4 ]
Wang, Mengfan [1 ,4 ]
Su, Rongxin [1 ,3 ,4 ]
He, Zhimin [1 ]
机构
[1] Tianjin Univ, Sch Chem Engn & Technol, State Key Lab Chem Engn, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Sch Environm Sci & Engn, Tianjin 300072, Peoples R China
[3] Coinnovat Ctr Chem & Chem Engn Tianjin, Tianjin 300072, Peoples R China
[4] Tianjin Key Lab Membrane Sci & Desalinat Technol, Tianjin 300072, Peoples R China
关键词
SURFACE-PLASMON RESONANCE; PIEZOELECTRIC IMMUNOSENSOR; SIGNAL AMPLIFICATION; SENSITIVE DETECTION; QCM IMMUNOSENSOR; ASSAY; BIOSENSOR; SENSOR; APTASENSOR; FREQUENCY;
D O I
10.1039/c4an02061h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel signal amplification strategy for quartz crystal microbalance (QCM) based on catalytic gas generation was developed to construct an ultrasensitive immunosensor for the detection of proteins (immunoglobulin G, IgG, used as a model). A catalase modified immunoparticle was prepared to form a sandwich-type immunocomplex with the IgG and anti-IgG antibodies that were immobilized on the QCM sensor. The amount of immunoparticles on the sensor surface was thus controlled by the IgG concentration. Then H2O2 was added and catalyzed by catalase for oxygen generation. The generated oxygen replaced some of the liquid on the sensor surface, leading to the change in the shear modulus of the immunocomplex layer and the apparent viscosity and density of the liquid layer. Due to the ultrasensitive response of QCM to these changes, a significant frequency shift related to the IgG concentration was achieved. Different parameters, including the flow cell structure, operation temperature, immunoparticle concentration, and H2O2 concentration were optimized to achieve steady and efficient frequency shifts. Under the optimal conditions, the proposed gas-phase amplified QCM sensor could achieve up to 72 times improvement of detection sensitivity compared to the label-free sensor as a control, in the concentration range of 0.1-3.0 mu g mL(-1). The detection limit was also reduced from 236 ng mL(-1) to 51.0 ng mL(-1) at the 3S(blank) level.
引用
收藏
页码:1174 / 1181
页数:8
相关论文
共 50 条
  • [1] Gas-phase pre-concentration for a quartz crystal microbalance based electronic nose
    Z. Ali
    D. James
    W. T. O'Hare
    F. J. Rowell
    S. M. Scott
    Journal of Thermal Analysis and Calorimetry, 2003, 71 : 163 - 171
  • [2] Gas-phase pre-concentration for a quartz crystal microbalance based electronic nose
    Ali, Z
    James, D
    O'Hare, WT
    Rowell, FJ
    Scott, SM
    JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY, 2003, 71 (01) : 163 - 171
  • [3] USE OF THE QUARTZ-CRYSTAL MICROBALANCE FOR THE STUDY OF ADSORPTION FROM THE GAS-PHASE
    TSIONSKY, V
    GILEADI, E
    LANGMUIR, 1994, 10 (08) : 2830 - 2835
  • [4] Immunosensor for the differentiation and detection of Salmonella species based on a quartz crystal microbalance
    Wong, YY
    Ng, SP
    Ng, MH
    Si, SH
    Yao, SZ
    Fung, YS
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (08): : 676 - 684
  • [5] Immunosensor based on quartz crystal microbalance for schistosoma egg antigen detection
    Xu, Lijian
    He, Nongyue
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [6] Quartz crystal microbalance immunosensor for schistosoma-japonicum
    Wu, ZY
    He, CP
    Wang, SP
    Shen, GL
    Yu, RQ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2001, 22 (04): : 542 - 546
  • [7] Human cytomegalovirus detection by a quartz crystal microbalance immunosensor
    Susmel, S
    O'Sullivan, CK
    Guilbault, GG
    ENZYME AND MICROBIAL TECHNOLOGY, 2000, 27 (09) : 639 - 645
  • [8] Polyaniline-Modified Quartz Crystal Microbalance Gas Sensor
    吴霞琴
    高尾雄二
    江头诚
    电化学, 1997, (03) : 102 - 105
  • [9] The Determination of Human Albumin by a Quartz Crystal Microbalance Immunosensor
    Pohanka, Miroslav
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 8471 - 8480
  • [10] Quartz Crystal Microbalance Immunosensor for Schistosoma-japonicum
    Inst. Chemometrics Chem. Sensing T., Hunan University, Changsha 410082, China
    不详
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 1600, 4 (546):